Indiacon CivilSubscribe

Textbook › Steel Design › Chapter 2 › Lesson 2.1

2.1 Bolted connections

Steel Design Chapter 2: Connections Under review — not yet three-checked Author: Indiacon

Learning objectives

After this lesson you should be able to:

  • Explain how a bearing-type bolt carries load by shear across the shear plane and by bearing on the plate, and how a friction grip bolt carries it by clamping and friction.
  • Find the design shear, bearing and tension strengths of bolts by IS 800:2007 cl. 10.3, including the reductions for long joints, large grips and thick packings, and the slip resistance of friction grip bolts by cl. 10.4.3.
  • Lay out a bolted joint within the spacing, edge and end distance limits of cl. 10.2 and check the connected plates.

Theory

A connection transfers force from one member to another, and in steel structures it is usually the place where a design is most likely to go wrong. IS 800:2007 cl. 10.1 asks that connections be designed to match the assumptions of the analysis and be able to transmit the design actions. Bolts are the normal choice for site joints because they need only a spanner or a wrench, no power supply and no welding inspection, and because a bolted joint can be taken apart. Under cl. 10.1.6 the partial safety factors for connections are those of Table 5: 1.25 for bolts in bearing-type joints.

In a bearing-type joint the plates are tightened only snugly. When the joint is loaded the plates slip until the bolt shanks touch the sides of their holes; the bolt is then sheared across each plane where the plates meet, and its shank presses on the wall of each hole. So each bolt has two strengths: its shear strength, which depends on the bolt material, its area and the number of shear planes, and its bearing strength on the plate, which depends on the bolt diameter, the plate thickness and strength, and how far the hole is from the end of the plate and from the next hole. Under cl. 10.3.2 the design strength of the bolt is the smaller of the two. In shear, cl. 10.3.1.1 and 10.3.3 take the net area at the threads where threads cross a shear plane and the shank area where they do not, so a bolt whose threads stay out of the shear plane is stronger.

Bolted lap joint: shear and bearingTTpegd0plate 1plate 2bolts in shear at the plane between the platesand in bearing on the walls of the holes
Figure 2.1: Bolted lap joint in plan: pitch p, end distance e, gauge g and hole diameter d0; the bolts act in shear at the plane between the plates and in bearing on the hole walls. Indiacon original, not to scale.

Bearing is limited by tearing of the plate in front of the hole. Cl. 10.3.4 gives a nominal bearing strength of 2.5 kb d t fu, where kb is the smallest of e/(3 d0), p/(3 d0) − 0.25, fub/fu and 1.0. A bolt close to the end of a plate (small e) or close to the next bolt (small p) tears out of the plate before it reaches full bearing, which is why spacing and end distance matter. Cl. 10.2 sets the geometry: holes are normally the bolt diameter plus the clearance of Table 19 (1 mm for 12 to 14 mm bolts, 2 mm for 16 to 24 mm, 3 mm above 24 mm); bolts are at least 2.5 times the nominal diameter apart (cl. 10.2.2); the edge and end distance is at least 1.7 times the hole diameter for sheared or hand-flame cut edges and 1.5 times for rolled, machine-flame cut, sawn and planed edges (cl. 10.2.4.2); and the edge distance should not exceed 12 tε (cl. 10.2.4.3).

The maximum spacing keeps plates in contact and stops the plate between bolts from buckling or letting moisture in. Under cl. 10.2.3.1 adjacent bolts are not more than 32t or 300 mm apart, whichever is less; along the line of force cl. 10.2.3.2 limits the pitch to 16t or 200 mm in tension members and 12t or 200 mm in compression members, t being the thickness of the thinner plate. In a long joint the end bolts take more than their share, so cl. 10.3.3.1 reduces the shear capacity by βlj = 1.075 − lj/(200 d), between 0.75 and 1.0, when the joint length exceeds 15 d. Cl. 10.3.3.2 reduces it by βlg = 8 d/(3 d + lg) when the grip exceeds 5 d, the grip being limited to 8 d, and cl. 10.3.3.3 by βpk = 1 − 0.0125 tpk when the bolt passes through a packing more than 6 mm thick.

Bolts can also be pulled along their axis, as in hangers and end-plate connections. Cl. 10.3.5 gives the nominal tension capacity 0.90 fub An, not more than fyb Asb (γmb/γm0), and cl. 10.3.6 limits a bolt carrying shear and tension together. Where slip cannot be tolerated, for example under vibration, load reversal or in joints that must stay stiff, cl. 10.4 and 10.9 call for high strength friction grip bolts to IS 3757, installed as in IS 4000. They are tightened to a proof load Fo = Anb f0 with f0 = 0.70 fub, and the clamping force carries the shear by friction: Vnsf = μf ne Kh Fo (cl. 10.4.3), with the slip factor μf from Table 20 (for example 0.50 for surfaces blasted with shot or grit with loose rust removed, 0.33 for clean mill scale, 0.20 for untreated surfaces), ne the number of friction interfaces, Kh = 1.0 in clearance holes, and γmf = 1.10 if slip resistance is designed at service load or 1.25 if designed at ultimate load. If such bolts are designed not to slip only at service loads, their ultimate capacity is checked as bearing bolts (cl. 10.4.4).

Derivation

  1. Bolt shear: by the von Mises criterion a material in pure shear yields or fails at its tensile value divided by √3. Applying this to the ultimate strength of the bolt over the area at each shear plane gives the nominal shear capacity Vnsb = (fub/√3)(nn Anb + ns Asb), where nn planes cut the threads (area Anb) and ns planes cut the plain shank (area Asb). Dividing by γmb = 1.25 gives the design value Vdsb.
  2. Thread area: for an ISO metric coarse thread the tensile stress area is As = (π/4)(d − 0.9382 p)², with p the thread pitch. For an M20 bolt (p = 2.5 mm): As = (π/4)(20 − 2.3455)² = 244.8 mm², taken as 245 mm², about 0.78 of the shank area π × 20²/4 = 314.2 mm². This 245 mm² is used for Anb and An below.
  3. Bearing: the shank presses on a projected area d × t. Tests show that the plate can carry about 2.5 times fu on that area if the hole is far enough from the end and from the next hole; nearer, the plate shears out along two planes in front of the bolt, which is what the e/(3 d0) and p/(3 d0) − 0.25 terms of kb represent. The expression 2.5 kb d t fu is therefore a calibrated rule, not a closed derivation.
  4. Load sharing: under a load through the centroid of the bolt group, ductile yielding at the most loaded holes lets all bolts reach their strength, so the force is shared equally: n = Factored force/bolt value. In a long joint the plates stretch between bolts and the end bolts take more, hence βlj.
  5. Friction grip: friction on one interface is μ times the normal force; with ne interfaces each carrying the clamping force Fo, the slip resistance is μf ne Fo, multiplied by Kh for the hole type: Vnsf = μf ne Kh Fo.
Formulas, symbols and SI units
  • Bolt shear (IS 800:2007 cl. 10.3.3): Vdsb = Vnsb/γmb; Vnsb = (fub/√3)(nn Anb + ns Asb) βlj βlg βpk (N; areas in mm², fub in N/mm²); γmb = 1.25
  • Reductions: βlj = 1.075 − lj/(200 d), 0.75 ≤ βlj ≤ 1.0, when lj > 15 d (cl. 10.3.3.1); βlg = 8 d/(3 d + lg) when lg > 5 d, βlg ≤ βlj, lg ≤ 8 d (cl. 10.3.3.2); βpk = 1 − 0.0125 tpk (tpk in mm) for packings over 6 mm (cl. 10.3.3.3)
  • Bearing (cl. 10.3.4): Vdpb = Vnpb/γmb; Vnpb = 2.5 kb d t fu; kb = smallest of e/(3 d0), p/(3 d0) − 0.25, fub/fu, 1.0 (d, t, e, p, d0 in mm)
  • Bolt value Vdb = smaller of Vdsb and Vdpb (cl. 10.3.2); number of bolts n = Vu/Vdb (rounded up)
  • Tension (cl. 10.3.5): Tdb = Tnb/γmb; Tnb = 0.90 fub An ≤ fyb Asb (γmb/γm0)
  • Shear with tension (cl. 10.3.6): (Vsb/Vdb)² + (Tb/Tdb)² ≤ 1.0
  • Friction grip (cl. 10.4.3): Vdsf = Vnsf/γmf; Vnsf = μf ne Kh Fo; Fo = Anb f0, f0 = 0.70 fub; γmf = 1.10 (slip at service load) or 1.25 (slip at ultimate load)
  • Geometry (cl. 10.2): d0 = d + 1, 2 or 3 mm (Table 19); pitch ≥ 2.5 d; edge and end ≥ 1.7 d0 (sheared, hand-flame cut) or 1.5 d0 (rolled, machine-flame cut, sawn, planed); edge ≤ 12 tε; spacing ≤ 32t or 300 mm; pitch along the force ≤ 16t or 200 mm (tension), 12t or 200 mm (compression)
  • Bolt property class m.n (IS 1367): fub = 100 m N/mm², fyb = 10 m n N/mm²; class 4.6: fub = 400, fyb = 240 N/mm²; class 8.8: fub = 800, fyb = 640 N/mm²
Assumptions and limits
  • The force passes through the centroid of the bolt group and is shared equally; eccentric loads are taken in lesson 2.3.
  • Bearing-type bolts are snug-tight and the joint is allowed to slip into bearing; where slip is not allowed, friction grip bolts are used.
  • Threads are assumed to lie in the shear plane unless the detailing guarantees otherwise.
  • Plates and bolts are ductile, so residual stresses from tightening and normal fit-up tolerances are ignored (cl. 10.1.4).
  • The block shear of the plate around the bolt group is a separate check, covered with tension members.
  • The rules are for static loads; fatigue-loaded joints need the checks of Section 13.

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • IS 800:2007 cl. 10.1.4 (ductility allows residual and tightening stresses to be ignored), cl. 10.1.5 (one form of fastener normally designed to carry the whole load), cl. 10.1.6 (partial safety factors of Table 5), cl. 10.2.1 with Table 19 (hole clearances), cl. 10.2.2 (minimum spacing 2.5 times the nominal diameter), cl. 10.2.3.1 and 10.2.3.2 (maximum spacing and pitch), cl. 10.2.4.2 (minimum edge and end distances), cl. 10.2.4.3 (maximum edge distance 12 tε).
  • IS 800:2007 cl. 10.3.1.1 (net area at the threads in a threaded shear plane), cl. 10.3.2 (bolt value the smaller of shear and bearing), cl. 10.3.3 (shear capacity), cl. 10.3.3.1, 10.3.3.2 and 10.3.3.3 (long joints, large grips, packings), cl. 10.3.4 (bearing, 2.5 kb d t fu), cl. 10.3.5 (tension), cl. 10.3.6 (combined shear and tension), cl. 10.4.1, 10.4.2, 10.4.3 with Table 20 (friction grip bolts, slip resistance, slip factors), cl. 10.4.4 (capacity after slip), cl. 10.9 (choice of fasteners where slip is to be avoided or under vibration). Friction grip bolts to IS 3757 and their installation to IS 4000; bolt property classes to IS 1367; all named by number only.
  • EN 1993-1-8 (Eurocode 3, design of joints) sorts bolted connections into categories by whether they are bearing-type or slip-resistant at serviceability or at ultimate load, and gives shear, bearing and slip resistances of individual fasteners with its own spacing rules. AISC 360 Chapter J, used with the RCSC specification for structural joints, separates snug-tightened, pretensioned and slip-critical joints and checks bolt shear, bearing and tear-out at holes, and slip. The approaches are listed side by side, not ranked; their factor values are not quoted here.

Worked examples

Example 1 (lap joint with bearing bolts, site style)

Problem. Two 12 mm E250 plates (fu = 410 N/mm²), 150 mm wide, are lapped and joined by M20 bolts of property class 4.6 (fub = 400 N/mm²) in standard holes with machine-cut edges. Threads lie in the single shear plane. End distance 40 mm, pitch 60 mm, two lines of bolts 40 mm from each edge. Find the bolt value and the number of bolts for a factored tension of 200 kN, and check the layout and the plates.

  1. Hole d0 = 20 + 2 = 22 mm (Table 19). Anb = 245 mm².
  2. Shear: Vdsb = (400/√3) × 245/1.25 = 230.9 × 245/1.25 = 45 264 N = 45.26 kN.
  3. Bearing: kb = smallest of 40/(3 × 22) = 0.606, 60/66 − 0.25 = 0.659, 400/410 = 0.976 and 1.0, so kb = 0.606. Vdpb = 2.5 × 0.606 × 20 × 12 × 410/1.25 = 119 273 N = 119.3 kN.
  4. Bolt value Vdb = 45.26 kN (shear governs). n = 200/45.26 = 4.42; provide 6 bolts in two lines of three for a symmetric pattern, capacity 6 × 45.26 = 271.6 kN.
  5. Layout: pitch 60 ≥ 2.5 × 20 = 50 mm; end and edge 40 ≥ 1.5 × 22 = 33 mm; gauge 150 − 2 × 40 = 70 mm ≥ 50 mm; edge 40 ≤ 12 × 12 × 1.0 = 144 mm; pitch 60 ≤ 16 × 12 = 192 mm. Joint length 2 × 60 = 120 mm < 15 d = 300 mm and grip 24 mm < 5 d = 100 mm, so no reductions.
  6. Plates: Tdg = 150 × 12 × 250/1.10 = 409.1 kN; An = (150 − 2 × 22) × 12 = 1 272 mm², Tdn = 0.9 × 1 272 × 410/1.25 = 375.5 kN. Both exceed 200 kN.

Answer. Bolt value 45.26 kN (shear); 6 bolts M20 class 4.6, capacity 271.6 kN; plates 375.5 kN by rupture

Example 2 (friction grip splice, site style)

Problem. A double-cover splice in a crane runway bracing must not slip. It uses M20 high strength friction grip bolts of property class 8.8 (fub = 800 N/mm², Anb = 245 mm²) in clearance holes, with faying surfaces blasted with grit and loose rust removed (μf = 0.50, Table 20). Find the slip resistance per bolt designed at ultimate load and at service load, and the number of bolts for a factored force of 600 kN with slip resistance designed at ultimate load.

  1. Proof stress f0 = 0.70 × 800 = 560 N/mm²; Fo = 245 × 560 = 137 200 N = 137.2 kN.
  2. Double cover: ne = 2 interfaces; Kh = 1.0. Vnsf = 0.50 × 2 × 1.0 × 137.2 = 137.2 kN.
  3. At ultimate load γmf = 1.25: Vdsf = 137.2/1.25 = 109.8 kN. At service load γmf = 1.10: Vdsf = 137.2/1.10 = 124.7 kN.
  4. Number of bolts: 600/109.8 = 5.47; provide 6 bolts on each side of the splice.
  5. The plates and covers are still checked for yielding and rupture, and the bolts in bearing at ultimate load where slip resistance is designed at service load only (cl. 10.4.4).

Answer. Slip resistance 109.8 kN per bolt (ultimate) or 124.7 kN (service); 6 bolts each side

Example 3 (long joint, large grip and packing, exam style)

Problem. M20 class 4.6 bolts (Anb = 245 mm², threads in the single shear plane) join two heavy plates 50 mm and 52 mm thick in a lap joint, with an 8 mm packing between them, so the grip is 110 mm. The bolts are in two lines of four at 120 mm pitch along the force, so the joint length is 360 mm. Find the reduced design shear strength per bolt and the number of bolts for a factored shear of 300 kN. End distance 40 mm, hole 22 mm, fu = 410 N/mm².

  1. Unreduced Vdsb = 45.26 kN (Example 1).
  2. Long joint: lj = 3 × 120 = 360 mm > 15 × 20 = 300 mm. βlj = 1.075 − 360/(200 × 20) = 1.075 − 0.090 = 0.985.
  3. Large grip: lg = 110 mm > 5 × 20 = 100 mm and ≤ 8 × 20 = 160 mm. βlg = 8 × 20/(3 × 20 + 110) = 160/170 = 0.941 ≤ βlj.
  4. Packing: 8 mm > 6 mm, βpk = 1 − 0.0125 × 8 = 0.90.
  5. Reduced Vdsb = 45.26 × 0.985 × 0.941 × 0.90 = 37.77 kN. Bearing on the 50 mm plate: kb = 40/66 = 0.606 (120/66 − 0.25 = 1.568 does not govern), Vdpb = 2.5 × 0.606 × 20 × 50 × 410/1.25 = 497.0 kN, far larger.
  6. n = 300/37.77 = 7.94; the 8 bolts provided (two lines of four) are just enough, 8 × 37.77 = 302.2 kN.

Answer. Reduced shear 37.77 kN per bolt (factor 0.834); 8 bolts carry 302.2 kN ≥ 300 kN

Step-by-step procedure

  1. Find the factored force on the connection, not less than the minimum design action of cl. 10.7 (for example 0.3 times the member capacity at the end of a tension or compression member).
  2. Choose the bolt type: bearing bolts for ordinary static joints, friction grip bolts where slip must be avoided or under vibration (cl. 10.9).
  3. Choose diameter and property class; find d0 from Table 19 and the areas Asb and Anb.
  4. Compute the bolt value: shear (number of shear planes, threads in or out) and bearing (kb from e, p, fub/fu), and take the smaller; for friction grip bolts compute Vdsf.
  5. Find the number of bolts and set them out within the spacing, edge and end distance limits of cl. 10.2.
  6. Apply βlj, βlg and βpk where the joint length, grip or packing exceed their limits, and recheck the number.
  7. Check the connected plates and gussets for yielding, rupture at the net section and block shear.

Site notes

  • Bolts, nuts and washers of the specified class are kept in labelled bins by lot; a class 4.6 bolt fitted in place of a class 8.8 bolt has half the strength and is hard to spot once installed, so the head markings are checked.
  • Holes are drilled or punched to the Table 19 size and deburred; reaming of misaligned holes is done only with the designer's agreement, and gas-cutting of bolt holes is not accepted.
  • For friction grip joints the faying surfaces are prepared as specified (for example grit blasted) and kept free of paint, oil and loose rust, and the bolts are tightened to the proof load by a method of IS 4000 and checked.
  • Threads should be kept out of the shear plane where the design assumes shank area; the bolt length and the number of washers are chosen with this in mind.
  • Each bolt is tightened in sequence from the centre of the joint outwards so that the plates are pulled into contact.
Common mistakes
  • Using the shank area in shear when the threads cross the shear plane; the net area at the threads (about 0.78 of the shank area) applies.
  • Forgetting bearing: with a small end distance kb = e/(3 d0) can make bearing govern.
  • Taking kb with the bolt diameter d instead of the hole diameter d0.
  • Counting a double-cover joint as single shear, or a lap joint as double shear.
  • Ignoring the long-joint, large-grip and packing reductions.
  • Using γmf = 1.10 when the slip resistance is meant to hold at ultimate load; it is 1.25 then.
Quick check

An M20 class 4.6 bolt with threads in the shear plane is worth about 45 kN in single shear and twice that in double shear; in a 12 mm E250 plate with a 40 mm end distance its bearing value is about 119 kN, so shear governs ordinary single-shear joints in plates over about 5 mm. The figures hold for standard holes and joints without length, grip or packing reductions.

Summary

  • A bearing-type bolt has a shear strength (cl. 10.3.3) and a bearing strength 2.5 kb d t fu (cl. 10.3.4); its design value is the smaller, with γmb = 1.25.
  • kb is the smallest of e/(3 d0), p/(3 d0) − 0.25, fub/fu and 1.0, so end distance and pitch control bearing.
  • Spacing ≥ 2.5 d; edge and end ≥ 1.5 d0 or 1.7 d0; pitch ≤ 16t or 200 mm in tension; spacing ≤ 32t or 300 mm.
  • Long joints, large grips and thick packings reduce the shear capacity by βlj, βlg and βpk.
  • Friction grip bolts carry shear by friction: Vnsf = μf ne Kh Fo with Fo = 0.70 fub Anb, and γmf = 1.10 or 1.25.

Practice questions

Tap a question to see the answer.

1Find the design shear strength of an M20 class 4.6 bolt in double shear with threads in one shear plane and the shank in the other (Anb = 245 mm², Asb = 314.2 mm²).

Vnsb = (400/√3)(245 + 314.2) = 129.1 kN; Vdsb = 129.1/1.25 = 103.3 kN.

2Find the minimum pitch and the minimum end distance at a sheared edge for M24 bolts in standard holes.

Pitch ≥ 2.5 × 24 = 60 mm; d0 = 24 + 2 = 26 mm, end ≥ 1.7 × 26 = 44.2 mm.

3In a tension member the thinner plate is 10 mm. Find the maximum pitch along the force and the maximum spacing of adjacent bolts.

Pitch ≤ 16 × 10 = 160 mm (less than 200 mm); spacing ≤ 32 × 10 = 320 mm, so 300 mm governs.

4Find the design tension capacity of an M20 class 4.6 bolt (An = 245 mm², Asb = 314.2 mm², fyb = 240 N/mm²).

0.90 × 400 × 245 = 88.2 kN, limited to 240 × 314.2 × 1.25/1.10 = 85.7 kN; Tdb = 85.7/1.25 = 68.5 kN.

5A bolt with Vdb = 45.26 kN and Tdb = 68.5 kN carries a factored shear of 30 kN and tension of 40 kN. Is it safe?

(30/45.26)² + (40/68.5)² = 0.44 + 0.34 = 0.78 ≤ 1.0: safe.

6Why does IS 800 ask for friction grip bolts or locking devices in joints under vibration?

Snug-tight bolts can slip back and forth and loosen under repeated load; clamped friction joints do not slip, and locking devices stop nuts turning (cl. 10.9).

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • N. Subramanian, Design of Steel Structures, Oxford University Press, New Delhi, 1st edition, 2008.
  • S. K. Duggal, Limit State Design of Steel Structures, McGraw Hill Education (India), 3rd edition, 2019.
Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.

Sent privately to the Indiacon editor; not published.