4.3 Column bases
After this lesson you should be able to:
- Explain how a column base passes axial force, moment and shear into a concrete pedestal, and state the IS 800:2007 bearing limit 0.6 fck and friction coefficient 0.45 (cl. 7.4.1).
- Size a rectangular slab base for axial compression and find its thickness from ts = √[2.5 w (a² − 0.3 b²) γm0 / fy] ≥ tf, or from the effective-area version with c² (cl. 7.4.1.1, cl. 7.4.3.1).
- Decide when a slab base is enough and when a gusseted base, shear key or anchor-bolt design is needed, including the linear-pressure check under moment and the seismic base rules of cl. 12.12.
Theory
Every steel column ends on something weaker than itself. An E250 rolled section may be stressed to about 227 N/mm² (250/1.10) on its own small area, while the concrete pedestal below can safely take only a fraction of that. The column base spreads the load over a larger area so the bearing pressure stays within what the concrete or grout can resist, and it also holds the column in position, carries any base moment and passes horizontal shear into the foundation. IS 800:2007 cl. 7.4.1 states the duty in those terms: the base must have enough stiffness and strength to transmit axial force, bending moment and shear without exceeding the capacity of the support, with anchor bolts and shear keys provided wherever necessary.
Two numbers from cl. 7.4.1 drive most hand designs. First, the maximum bearing pressure on the support must not exceed 0.6 fck, where fck is the smaller of the characteristic cube strength of the pedestal concrete and of the bedding (grout) material. For an M25 pedestal with grout at least as strong, the limit is 0.6 × 25 = 15 N/mm². Second, shear resistance at the contact surface between the steel base and the concrete or grout may be calculated with a friction coefficient of 0.45, so the horizontal force that friction alone can carry is 0.45 times the compression acting at the same time. The clause also allows the bearing pressure to be taken as varying linearly, which is the basis of the P/A ± M/Z check for bases with moment.
A slab base is a single thick plate welded or bolted to the end of the column, with no gussets (cl. 7.4.3). It is the usual choice for axially loaded columns and for small moments. The plate bends upward like a cantilever under the soil-like pressure w from below, and the critical sections lie near the column faces. Cl. 7.4.3.1 gives the minimum thickness of a rectangular slab base under axial compression as ts = √[2.5 w (a² − 0.3 b²) γm0 / fy], and ts must not be less than the flange thickness tf of the column. Here w is the uniform pressure from below under the factored axial load, and a and b are the larger and smaller projections of the plate beyond the rectangle that circumscribes the column. The −0.3 b² term reflects two-way plate action: with projections in both directions the plate is stiffened by bending the other way, so it needs less thickness than a pure one-way cantilever of length a.
Often the plate is made larger than bearing alone needs, for example to fit anchor bolts or because the pedestal is wide. Then the outer parts of a thin plate deflect and carry little pressure. Cl. 7.4.1.1 allows an equal projection c of the plate beyond the faces of the column (and of any gusset) to be taken as the effective bearing area, sized so that the pressure on that area does not exceed the bearing capacity. When only that effective area is used, c² replaces (a² − 0.3 b²) in the thickness expression (cl. 7.4.3.1). For an I-section the effective area is the column outline grown by c on every side — two flange bands joined by a web band — so it is found by solving a quadratic in c, as Example 2 shows.
A gusseted base adds vertical gusset plates, angle cleats or stiffeners between the column shaft and the base plate (cl. 7.4.2). The gussets shorten the cantilever spans of the base plate, spread a base moment over a longer lever arm and let a thinner plate do the job. The gussets, cleats, stiffeners and fastenings, together with the bearing area of the shaft, must take all the loads, moments and reactions. If the ends of the shaft and gussets are faced (machined) for full bearing, compression passes by contact; if they are not, cl. 7.4.2.1 requires the welds or fasteners to carry all the forces. Where the column is joined to the base plate by full penetration butt welds, cl. 7.4.2.2 deems the joint to transmit all forces and moments.
Practical rules complete the picture. A slab base still needs fastenings that hold the parts together and resist the forces of transit, unloading and erection, not just service compression (cl. 7.4.3). When the load is eccentric and the pressure from below is not uniform, the thickness expression no longer applies directly and a separate calculation of the plate moment is required (cl. 7.4.3.2). Bases bearing on concrete or masonry need not be machined on the underside (cl. 7.4.3.3), but where a cap or base is fillet welded to the column end without boring and shouldering, the contact surfaces must be machined for full bearing unless full-strength butt welds are used (cl. 7.4.3.4). In seismic design, cl. 12.12.1 asks fixed bases and their anchor bolts to resist 1.2 times the full plastic moment capacity of the column, and cl. 12.12.2 asks both fixed and hinged bases to resist the full shear under any load case or 1.2 times the shear capacity of the column section, whichever is higher.
EN 1993-1-8 (base plates by an equivalent T-stub and effective area under the column) and the AISC Design Guide 1 for base plates and anchor rods (cantilever and Thornton-type plate models) cover the same physics with their own notation. This lesson follows IS 800:2007 and names the other methods only for comparison; it does not rank them.
Derivation
- Bearing area (cl. 7.4.1): A_req = Pu / (0.6 fck). Choose plate L × B ≥ A_req, then w = Pu / (L × B) ≤ 0.6 fck.
- Projections: a = larger of (L − h)/2 and (B − bf)/2; b = the smaller, where h is column depth and bf flange width.
- One-way cantilever idea: moment per unit width at the column face = w a²/2. With plastic moment capacity per unit width fy t²/(4 γm0) the thickness would be t = √(2 w a² γm0 / fy). The code expression √[2.5 w (a² − 0.3 b²) γm0 / fy] uses the factor 2.5 and the two-way relief term −0.3 b² instead (cl. 7.4.3.1).
- Dimension check: w (N/mm²) × a² (mm²) / fy (N/mm²) gives mm², so the square root gives a thickness in mm.
- Effective area for an I-section with flange width bf, flange thickness tf, depth h and web thickness tw (cl. 7.4.1.1): A_eff(c) = 2 (bf + 2c)(tf + 2c) + (tw + 2c)(h − 2tf − 2c) = 4c² + [2(bf + 2tf) + 2(h − 2tf) − 2tw]c + (column area), valid while h − 2tf − 2c > 0. Set A_eff = Pu/(0.6 fck), solve for c, then ts = c √(2.5 w γm0 / fy) with w = 0.6 fck.
- Moment with small eccentricity (cl. 7.4.1 linear pressure): e = Mu/Pu; if e ≤ L/6, p_max,min = (Pu/(L B))(1 ± 6e/L), both compressive.
Bearing limit: w ≤ 0.6 fck (N/mm²), fck = smaller cube strength of concrete or grout (cl. 7.4.1)Friction shear: V_f = 0.45 × P_concurrent (kN) (cl. 7.4.1)Slab base thickness: ts = √[2.5 w (a² − 0.3 b²) γm0 / fy] ≥ tf (mm) (cl. 7.4.3.1)Effective-area version: ts = √[2.5 w c² γm0 / fy] (mm) (cl. 7.4.1.1, cl. 7.4.3.1)Eccentric base, e ≤ L/6: p = (P/A)(1 ± 6e/L) (N/mm²)γm0 = 1.10 (Table 5); E250: fy = 250 N/mm²
- Static loading; fatigue and impact are outside this lesson.
- Plate is a single rectangular steel plate of E250 grade; thickness ≤ 40 mm so fy = 250 N/mm² is used as given data.
- Pressure from below is uniform for axial load (w = Pu/A) and linear for small eccentricity; cracked-pedestal and anchor-tension cases (e > L/6) need a separate analysis and are only outlined.
- Section dimensions in examples are idealised given design data (root fillets ignored).
- Grout is at least as strong as the pedestal unless stated, so fck refers to the pedestal concrete.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- IS 800:2007 cl. 7.4.1 (general: transfer of axial force, moment and shear; anchor bolts and shear keys; friction coefficient 0.45; linear pressure; bearing ≤ 0.6 fck) and cl. 7.4.1.1 (effective area with equal projection c).
- IS 800:2007 cl. 7.4.2 (gusseted bases), cl. 7.4.2.1 (welds or fasteners where not faced for bearing), cl. 7.4.2.2 (full penetration butt welds).
- IS 800:2007 cl. 7.4.3 (slab bases), cl. 7.4.3.1 (thickness ts ≥ tf), cl. 7.4.3.2 (non-uniform pressure), cl. 7.4.3.3 (underside machining), cl. 7.4.3.4 (welded caps and bases).
- IS 800:2007 cl. 12.12.1 and 12.12.2 (column bases in seismic design); Table 5 (γm0 = 1.10).
- For comparison only: EN 1993-1-8 (base plates) and AISC Design Guide 1 (base plate and anchor rod design). Not ranked; no values quoted.
Worked examples
Problem. An I-section column of depth h = 300 mm, flange width bf = 250 mm and flange thickness tf = 10.6 mm (given design data) carries a factored axial load Pu = 1 500 kN. The pedestal is M25 concrete with grout at least as strong. Size a rectangular slab base of E250 steel and find its thickness. Take γm0 = 1.10.
- Bearing limit (cl. 7.4.1): 0.6 fck = 0.6 × 25 = 15 N/mm².
- Required area: A_req = 1 500 × 10³ / 15 = 100 000 mm².
- Adopt a plate 460 mm × 380 mm (long side along the column depth): A = 174 800 mm² ≥ 100 000 mm². Pressure w = 1 500 × 10³ / 174 800 = 8.581 N/mm² ≤ 15 — OK.
- Projections: along depth (460 − 300)/2 = 80 mm; along width (380 − 250)/2 = 65 mm. So a = 80 mm, b = 65 mm.
- a² − 0.3 b² = 6 400 − 0.3 × 4 225 = 5 132.5 mm².
- ts = √(2.5 × 8.581 × 5 132.5 × 1.10 / 250) = √484.5 = 22.01 mm (cl. 7.4.3.1).
- Check ts ≥ tf: 22.01 ≥ 10.6 — OK. Adopt a 25 mm plate (next standard thickness above 22.01 mm).
Answer. Plate 460 × 380 × 25 mm; w = 8.58 N/mm² ≤ 15; ts,req = 22.01 mm
Problem. The same column and load as Example 1 sit on a 600 mm × 550 mm plate chosen to suit the anchor-bolt layout. Web thickness tw = 7.6 mm (given). Use the effective-area method of cl. 7.4.1.1 to find the projection c and the plate thickness, and compare with the full-area expression.
- Column area (idealised): 2 × 250 × 10.6 + 7.6 × (300 − 2 × 10.6) = 5 300 + 2 118.9 = 7 418.9 mm².
- A_eff(c) = 2(250 + 2c)(10.6 + 2c) + (7.6 + 2c)(278.8 − 2c) = 4c² + 1 584.8c + 7 418.9.
- Set A_eff = 1 500 × 10³ / 15 = 100 000 mm²: 4c² + 1 584.8c − 92 581.1 = 0, so c = 51.68 mm. Check web band height 278.8 − 2 × 51.68 = 175.4 mm > 0, and c is less than the actual projections (150 mm and 150 mm) — OK.
- With w = 15 N/mm² on the effective area: ts = c √(2.5 × 15 × 1.10 / 250) = 51.68 × 0.4062 = 20.99 mm ≥ 10.6 mm. Adopt 22 mm.
- Full-area expression for comparison: w = 1 500 × 10³ / (600 × 550) = 4.545 N/mm²; a = b = 150 mm; a² − 0.3 b² = 15 750 mm²; ts = √(2.5 × 4.545 × 15 750 × 1.10 / 250) = 28.06 mm.
- For an oversize plate the effective-area route gives the thinner plate (about 21 mm against 28 mm), because it does not ask the far corners of the plate to carry pressure.
Answer. c = 51.68 mm; ts = 20.99 mm (adopt 22 mm); full-area route would need 28.06 mm
Problem. A column base plate 500 mm (in the plane of bending) × 400 mm carries a factored axial load Pu = 800 kN with a base moment Mu = 40 kNm and a horizontal shear Vu = 120 kN. The pedestal is M25. In a second load case the concurrent compression drops to 200 kN with the same shear. Check bearing, and check whether friction alone (cl. 7.4.1) can carry the shear in each case.
- Eccentricity e = Mu/Pu = 40 × 10⁶ / (800 × 10³) = 50 mm. L/6 = 500/6 = 83.3 mm, so e ≤ L/6 and the whole plate is in compression.
- P/A = 800 × 10³ / (500 × 400) = 4.00 N/mm²; 6e/L = 6 × 50 / 500 = 0.60.
- p_max = 4.00 × 1.60 = 6.40 N/mm²; p_min = 4.00 × 0.40 = 1.60 N/mm². Both ≤ 15 N/mm² — bearing OK. Because pressure is not uniform, the plate thickness needs a separate moment calculation (cl. 7.4.3.2).
- Friction case 1: 0.45 × 800 = 360 kN ≥ 120 kN — friction is enough.
- Friction case 2: 0.45 × 200 = 90 kN < 120 kN — provide a shear key or design the anchor bolts for shear (cl. 7.4.1).
Answer. p_max = 6.40, p_min = 1.60 N/mm²; friction 360 kN OK, but 90 kN < 120 kN needs a shear key
Step-by-step procedure
- Collect factored Pu, Mu and Vu at the base for every load case, including the case with least compression and largest shear or uplift.
- Find the bearing limit 0.6 fck from the weaker of pedestal concrete and grout (cl. 7.4.1) and the required area Pu/(0.6 fck).
- Choose plate L × B to suit area, anchor bolts and pedestal edge distances; compute w and the projections a and b.
- Thickness: ts = √[2.5 w (a² − 0.3 b²) γm0 / fy] ≥ tf, or the effective-area version with c² for an oversize plate (cl. 7.4.1.1, cl. 7.4.3.1).
- With moment: check e = M/P; if e ≤ L/6 use p = (P/A)(1 ± 6e/L); if larger, analyse anchor-bolt tension and plate bending separately (cl. 7.4.3.2). Consider a gusseted base for large moments (cl. 7.4.2).
- Shear: compare Vu with 0.45 × concurrent compression; otherwise add a shear key or anchor bolts in shear (cl. 7.4.1). In seismic design apply cl. 12.12.1–12.12.2.
- Detail welds or fasteners for erection forces (cl. 7.4.3), machining or full-strength welds (cl. 7.4.2.1, cl. 7.4.3.4), and a grout gap.
Site notes
- Set the plate on levelling nuts or steel packs, align and plumb the column, then fill the gap with non-shrink grout; the grout strength enters the 0.6 fck bearing check, so it should not be weaker than assumed.
- Leave vent holes in large base plates so that air escapes and grout fills the whole bearing area; voids under the plate defeat the uniform-pressure assumption.
- Anchor bolts are set with templates before the pedestal is cast; record the as-built positions before the plate is drilled or the column is fabricated.
- Shear keys need a pocket in the pedestal that is grouted with the base; make sure the pocket is clean and fully filled.
- Check that the plate thickness on the fabrication drawing is a standard thickness at or above the calculated value, and that the column end is square to the plate.
- Using the pedestal grade alone when the grout is weaker; fck in 0.6 fck is the smaller of the two (cl. 7.4.1).
- Swapping a and b: a is the larger projection and b the smaller in (a² − 0.3 b²).
- Forgetting the square root in the thickness expression, which gives an answer in mm² instead of mm.
- Applying the uniform-pressure thickness formula to an eccentric base without the separate moment check (cl. 7.4.3.2).
- Counting friction for shear in the load case with low compression or uplift; the 0.45 coefficient applies only to the compression actually present.
- Accepting ts less than the column flange thickness tf.
Quick base check: area ≈ Pu/(0.6 fck); for M25 that is about 67 mm² per kN. Thickness ≈ √[2.5 w (a² − 0.3 b²) × 1.10 / 250] ≈ 0.105 √[w (a² − 0.3 b²)] mm for E250. Friction shear ≈ 0.45 × concurrent compression; if e > L/6, think anchor-bolt tension.
Summary
- A column base spreads load so bearing ≤ 0.6 fck and transfers moment and shear to the pedestal (cl. 7.4.1).
- Slab base thickness: ts = √[2.5 w (a² − 0.3 b²) γm0 / fy] ≥ tf (cl. 7.4.3.1).
- Oversize plates may use the effective area with equal projection c, and c² in the thickness expression (cl. 7.4.1.1).
- Friction at the steel–grout contact uses μ = 0.45; when it is not enough, use a shear key or anchor bolts in shear.
- Gusseted bases suit large moments; machining or full-strength welds govern how forces pass (cl. 7.4.2–7.4.2.2).
- Seismic bases follow cl. 12.12: 1.2 Mp for fixed bases and the higher of full shear or 1.2 × shear capacity.
Practice questions
Tap a question to see the answer.
1What is the bearing limit under a base plate on M30 concrete with M40 grout?
0.6 × 30 = 18 N/mm² (the smaller of the two strengths governs, cl. 7.4.1).
2A factored load of 2 000 kN sits on M25 concrete. What minimum plate area is needed?
2 000 × 10³ / 15 = 133 333 mm², for example a 400 × 340 mm plate (136 000 mm²) or larger.
3For w = 10 N/mm², a = 100 mm, b = 80 mm, E250, γm0 = 1.10, find ts.
a² − 0.3 b² = 10 000 − 1 920 = 8 080 mm²; ts = √(2.5 × 10 × 8 080 × 1.10 / 250) = √888.8 = 29.81 mm.
4With the effective-area method, c = 60 mm and w = 15 N/mm² for E250. Find ts.
ts = 60 × √(2.5 × 15 × 1.10 / 250) = 60 × 0.4062 = 24.37 mm.
5A base carries 500 kN compression and 200 kN shear. Is friction enough?
0.45 × 500 = 225 kN ≥ 200 kN — friction alone is enough (cl. 7.4.1).
6A 600 mm long plate (in the plane of bending) carries P = 1 000 kN and M = 120 kNm. Is the whole plate in compression?
e = 120/1 000 = 0.12 m = 120 mm > 600/6 = 100 mm, so part of the plate lifts; analyse anchor-bolt tension and plate bending separately (cl. 7.4.3.2).
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- N. Subramanian, Design of Steel Structures, Oxford University Press, New Delhi, 1st edition, 2008.
- S. K. Duggal, Limit State Design of Steel Structures, McGraw Hill Education (India), 3rd edition, 2019.