Indiacon CivilSubscribe

Textbook › Steel Design › Chapter 2 › Lesson 2.2

2.2 Welded connections

Steel Design Chapter 2: Connections Under review — not yet three-checked Author: Indiacon

Learning objectives

After this lesson you should be able to:

  • Describe fillet, butt, slot and plug welds and the terms used for them: size, effective throat thickness and effective length.
  • Find the design strength of fillet welds by IS 800:2007 cl. 10.5.7, for shop and site welds, including the throat factor K of Table 22 for inclined fusion faces.
  • Size and detail a welded lap or end connection within the minimum size, maximum size, effective length, end return, lap and long-joint rules of cl. 10.5.

Theory

Welding joins steel by melting the parent metal and a filler metal from an electrode so that they fuse into one piece. A welded joint needs no holes, so the full section of the member works, and it can join almost any shape, which is why fabrication shops weld girders, columns and brackets. Its drawbacks are the skill and inspection it needs, the heat that can distort the parts and leave residual stresses, and the difficulty of doing good work overhead or in wind and rain on site. IS 800:2007 cl. 10.5.1 asks for welds and welding to IS 816 and IS 9595, and cl. 10.5.6 asks for electrodes to IS 814.

Two weld types do almost all the work. A butt weld fills a gap or groove between parts in the same plane; with complete penetration its effective throat is the thickness of the thinner part (cl. 10.5.3.3), and under cl. 10.5.7.1.2 it is treated as parent metal of that thickness, so a good butt weld is as strong as the plate. A fillet weld is a triangular bead laid in the corner between two parts, as in a lap joint or a T-joint. Its size is the leg length s (cl. 10.5.2.1). It fails through its throat, the shortest distance from the root to the face, which for a fillet between faces at right angles is 0.7 s; for other angles cl. 10.5.3.2 multiplies the size by K from Table 22: 0.70 for 60° to 90°, 0.65 for 91° to 100°, 0.60 for 101° to 106°, 0.55 for 107° to 113° and 0.50 for 114° to 120°. Slot and plug welds fill holes in a lapping plate; under cl. 10.5.4.3 a plug weld is not designed to carry stress.

Fillet weld: leg, throat and side weldsssthroat 0.7 sfillet weld sectionside weldlwlap joint, plan
Figure 2.2: Fillet weld cross-section with equal legs s and throat 0.7 s, and a lap joint in plan with two side fillet welds of effective length lw. Indiacon original, not to scale.

The strength of a fillet weld comes from shear on its throat area. Cl. 10.5.7.1.1 gives the design strength fwd = fwn/γmw with fwn = fu/√3, where fu is the smaller of the ultimate stress of the weld and of the parent metal. With γmw = 1.25 for shop welds (Table 5) and 1.5 for site welds (cl. 10.5.7.2), a site weld is 20 per cent weaker than the same weld made in the shop. Under cl. 10.5.9 the stress in a weld carrying a single force is the force divided by the throat area tt lw; where normal and shear stresses act together, cl. 10.5.10.1.1 limits the equivalent stress fe = √(fa² + 3q²) to fu/(√3 γmw).

Detailing rules keep the weld sound. The size is at least 3 mm (cl. 10.5.2.3), and Table 21 sets the minimum size of the first or single run by the thickness of the thicker part, to avoid cracking from fast cooling: 3 mm up to 10 mm, 5 mm over 10 to 20 mm, 6 mm over 20 to 32 mm, and 8 mm for the first run (10 mm minimum size) over 32 to 50 mm; when the table value exceeds the thinner part, the weld size equals the thinner part and the thicker part is preheated. Cl. 10.5.3.1 keeps the effective throat at not less than 3 mm and generally not more than 0.7t of the thinner plate (1.0t in special cases), and a fillet on the square edge of a plate is kept at least 1.5 mm less than the edge thickness so the corner does not melt away (cl. 10.5.8.1). The effective length is the length of full size; in practice the weld is made the effective length plus twice the size, and the effective length is not less than four times the size (cl. 10.5.4.1). Welds are returned round corners for at least twice the size (cl. 10.5.1.1); a lap is at least four times the thinner part or 40 mm (cl. 10.5.1.2), and where a plate end is held only by side welds, each is at least as long as the distance between them.

Long side welds do not share load evenly, just as long bolted joints do not. When a welded joint is longer than 150 tt, cl. 10.5.4.4 and 10.5.7.3 reduce the design strength by the long-joint factor βlw of cl. 10.5.7.3; in flange-to-web welds loaded along their whole length the reduction does not apply. Intermittent fillet welds have an effective length of at least four times the size and at least 40 mm (cl. 10.5.5.1), and are not used where loads are dynamic or alternating (cl. 10.5.5.3).

Derivation

  1. Throat of a fillet weld: for equal legs s meeting at angle θ, the throat is the perpendicular from the root to the face, tt = s cos(θ/2). For θ = 90°, tt = s cos 45° = 0.707 s, rounded to 0.70 s. For 100° the throat is 0.643 s, for 106° 0.602 s, for 113° 0.552 s and for 120° 0.500 s, matching the K values 0.65, 0.60, 0.55 and 0.50 of Table 22 at the top of each band.
  2. Strength per unit length: the throat area per millimetre of weld is tt × 1 mm, so a weld of length lw carries P = fwd tt lw, with fwd = fu/(√3 γmw).
  3. Why fu/√3: the throat is in shear, and by the von Mises criterion shear failure occurs at the tensile value divided by √3; the same criterion gives the combined check fe = √(fa² + 3q²).
  4. Effective length: the start and the end of a run (the crater) are not of full size, so each end loses about one weld size: actual length = effective length + 2 s.
  5. Required length for a force P: lw = P/(fwd × K × s).
Formulas, symbols and SI units
  • Effective throat tt = K s (mm); K = 0.70 for fusion faces at 60° to 90° (IS 800:2007 cl. 10.5.3.2, Table 22)
  • Design strength of a fillet weld (cl. 10.5.7.1.1): fwd = fu/(√3 γmw) (N/mm²); γmw = 1.25 shop (Table 5), 1.5 site (cl. 10.5.7.2)
  • Weld capacity P = fwd tt lw (N); stress under a single force fa or q = P/(tt lw) (cl. 10.5.9)
  • Combined normal and shear stress (cl. 10.5.10.1.1): fe = √(fa² + 3q²) ≤ fu/(√3 γmw)
  • Size limits: s ≥ 3 mm and ≥ Table 21 value (3, 5, 6, 8 or 10 mm by thicker part); square edge s ≤ t − 1.5 mm (cl. 10.5.8.1); throat 3 mm ≤ tt ≤ 0.7t of the thinner plate (cl. 10.5.3.1)
  • Lengths: actual = effective + 2 s; effective ≥ 4 s (cl. 10.5.4.1); end return ≥ 2 s (cl. 10.5.1.1); lap ≥ 4t or 40 mm (cl. 10.5.1.2); long-joint reduction when lj > 150 tt (cl. 10.5.7.3)
  • Complete penetration butt weld: throat = thinner part; treated as parent metal (cl. 10.5.3.3, 10.5.7.1.2)
Assumptions and limits
  • Fillet welds are designed on the throat in shear, whatever the direction of the force; this is a simple and safe rule for side and end welds alike.
  • The force passes through the centroid of the weld group and is shared uniformly along its length; eccentric weld groups are in lesson 2.3.
  • The electrode is matched to the parent metal, so fu is the plate value; with a weaker electrode the weld value applies.
  • Residual stresses from welding are ignored in statically loaded structures (cl. 10.6.2); fatigue-loaded welds need Section 13.
  • Balancing side welds about the centroid of an angle is not required for statically loaded members (cl. 10.8).

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • IS 800:2007 cl. 10.5.1 (welding to IS 816 and IS 9595), cl. 10.5.1.1 (end returns), cl. 10.5.1.2 (lap joints), cl. 10.5.2.1 (size of fillet), cl. 10.5.2.3 with Table 21 (minimum size), cl. 10.5.3.1 (throat limits), cl. 10.5.3.2 with Table 22 (K factor), cl. 10.5.3.3 (butt weld throat), cl. 10.5.4.1 (effective length), cl. 10.5.4.3 (plug welds), cl. 10.5.4.4 and 10.5.7.3 (long joints over 150 tt), cl. 10.5.5.1 and 10.5.5.3 (intermittent welds), cl. 10.5.6 (electrodes to IS 814).
  • IS 800:2007 cl. 10.5.7.1.1 (fillet weld strength on the throat), cl. 10.5.7.1.2 (butt welds as parent metal), cl. 10.5.7.2 (site welds, γmw 1.5), Table 5 (γmw 1.25 shop), cl. 10.5.8.1 (fillet on a square edge 1.5 mm under the edge thickness), cl. 10.5.9 (stress from a single force), cl. 10.5.10.1.1 (equivalent stress), cl. 10.6.2 (residual stresses), cl. 10.7 (minimum design action), cl. 10.8 (balancing of welds). IS 816, IS 9595 and IS 814 named by number only.
  • EN 1993-1-8 gives two routes for fillet welds, a directional method that resolves the stresses on the throat into components and a simplified method using a design shear strength on the throat, with its own correlation factors for steel grades. AISC 360 Chapter J2, used with the AWS D1.1 structural welding code, gives the strength of fillet welds on the effective throat with an increase for welds loaded at an angle to their axis. The approaches are listed side by side, not ranked; their factor values are not quoted here.

Worked examples

Example 1 (lap joint with side welds, site style)

Problem. A 150 mm × 10 mm E250 plate (fu = 410 N/mm²) is lapped on a 12 mm gusset and carries a factored tension of 300 kN. Design shop fillet welds along the two edges of the plate.

  1. Plate: Tdg = 150 × 10 × 250/1.10 = 340.9 kN ≥ 300 kN.
  2. Size: Table 21 with the thicker part 12 mm gives at least 5 mm; on the square edge of the 10 mm plate at most 10 − 1.5 = 8.5 mm. Choose s = 6 mm; tt = 0.7 × 6 = 4.2 mm.
  3. fwd = 410/(√3 × 1.25) = 189.4 N/mm². Strength per mm = 4.2 × 189.4 = 795.4 N/mm.
  4. Required effective length = 300 000/795.4 = 377.2 mm; provide two side welds of 190 mm effective length (380 mm, capacity 380 × 795.4 = 302.2 kN).
  5. Actual length of each weld = 190 + 2 × 6 = 202 mm, made 205 mm, returned round the corners for at least 2 × 6 = 12 mm.
  6. Checks: each side weld 190 mm ≥ the 150 mm distance between them; lap well over 4 × 10 = 40 mm; 190 mm < 150 × 4.2 = 630 mm, so no long-joint reduction.

Answer. 6 mm shop fillets, 2 × 190 mm effective (205 mm made), capacity 302.2 kN ≥ 300 kN

Example 2 (site weld with inclined faces)

Problem. A bracket plate is welded on site to the sloping face of a member, so the fusion faces meet at 100°. Two 8 mm fillet welds carry a factored shear of 180 kN passing through their centroid; fu = 410 N/mm². Find the effective length needed, and compare with the same weld made in the shop.

  1. K for 91° to 100° = 0.65 (Table 22); tt = 0.65 × 8 = 5.2 mm.
  2. Site weld: fwd = 410/(√3 × 1.5) = 157.8 N/mm²; strength per mm = 5.2 × 157.8 = 820.6 N/mm.
  3. Required effective length = 180 000/820.6 = 219.3 mm; provide two welds of 110 mm effective length (220 mm), each made 110 + 2 × 8 = 126 mm, say 130 mm.
  4. Shop weld: fwd = 189.4 N/mm², strength 5.2 × 189.4 = 984.7 N/mm; required length 180 000/984.7 = 182.8 mm.
  5. The site weld needs 1.5/1.25 = 1.2 times the length: one more reason to weld in the shop and bolt on site.

Answer. Site: 219.3 mm needed, 2 × 110 mm provided; shop: 182.8 mm (ratio 1.2)

Example 3 (truss tie to gusset, exam style)

Problem. A truss tie is a 200 mm × 12 mm E250 flat (fu = 410 N/mm²) welded to a 12 mm gusset by two side fillet welds made in the shop. The factored tension is 450 kN. Choose the weld size and length.

  1. Tie: Tdg = 200 × 12 × 250/1.10 = 545.5 kN ≥ 450 kN. The minimum design action at the end of a tension member is 0.3 × 545.5 = 163.6 kN (cl. 10.7), less than 450 kN, so 450 kN governs.
  2. Size: Table 21 with the thicker part 12 mm gives at least 5 mm; on the square edge at most 12 − 1.5 = 10.5 mm. Choose s = 8 mm; tt = 5.6 mm.
  3. Strength per mm = 5.6 × 189.4 = 1 060.5 N/mm. Required total effective length = 450 000/1 060.5 = 424.3 mm, that is 212.2 mm per side.
  4. Provide 215 mm effective on each side (430 mm, capacity 430 × 1 060.5 = 456.0 kN); make each weld 215 + 2 × 8 = 231 mm, say 235 mm.
  5. Checks: 215 mm ≥ the 200 mm distance between the welds; 215 mm < 150 × 5.6 = 840 mm, no long-joint reduction; throat 5.6 mm ≤ 0.7 × 12 = 8.4 mm.

Answer. 8 mm shop fillets, 215 mm effective each side (235 mm made), capacity 456.0 kN ≥ 450 kN

Step-by-step procedure

  1. Find the factored force on the joint, not less than the minimum design action of cl. 10.7.
  2. Decide shop or site welding and the weld type (butt for full-strength in-line joints, fillet for laps and T-joints).
  3. Choose the fillet size between the Table 21 minimum and the maximum set by the plate edge and the throat limit of cl. 10.5.3.1.
  4. Find K from Table 22, the throat tt = K s and fwd = fu/(√3 γmw).
  5. Find the effective length P/(fwd tt), split it between the weld runs, and add 2 s to each run for the length to be made.
  6. Check end returns, lap length, side-weld length against their spacing, and the long-joint limit of 150 tt.
  7. Show weld symbols with size, length and shop or site on the drawings.

Site notes

  • Welders are qualified for the process and position, and the welding procedure (electrode, current, preheat, sequence) is approved before work starts.
  • Joints are clean, dry and free of rust, paint and mill scale where the weld will lie; damp electrodes are dried as the maker specifies.
  • Thick parts are preheated where Table 21 or the procedure requires it; welding in wind or rain on site is screened.
  • Fillet sizes are checked with a weld gauge; visual inspection looks for undercut, porosity, cracks and lack of fusion, and important butt welds are tested ultrasonically or by radiography.
  • A planned welding sequence, balanced about the axis of the member, limits distortion.
Common mistakes
  • Taking the leg size as the throat; the throat is 0.7 s for a right-angled fillet.
  • Using γmw = 1.25 for a site weld; it is 1.5.
  • Forgetting to add 2 s to the effective length for the length to be made.
  • Specifying a fillet on the square edge of a plate equal to its full thickness, which melts the edge away.
  • Using a fillet smaller than the Table 21 minimum on a thick plate, which risks cracking from fast cooling.
  • Using K = 0.70 for fusion faces that are not near a right angle.
Quick check

In E250 steel a shop fillet weld with fusion faces near 90° carries about 0.133 kN per millimetre for each millimetre of leg size (0.7 × 189.4 N/mm² = 132.6 N/mm per mm), so a 6 mm weld carries about 0.8 kN/mm and an 8 mm weld about 1.06 kN/mm. Site welds carry 1/1.2 of these values. The shortcut assumes electrodes at least as strong as the plate (fu = 410 N/mm²).

Summary

  • Fillet welds are designed on the throat tt = K s in shear: fwd = fu/(√3 γmw), γmw = 1.25 shop and 1.5 site.
  • K = 0.70 for fusion faces at 60° to 90°, falling to 0.50 at 114° to 120° (Table 22).
  • Minimum sizes come from Table 21 by the thicker part; the maximum on a square edge is 1.5 mm less than the edge thickness.
  • Actual weld length = effective length + 2 s; effective length ≥ 4 s; end returns ≥ 2 s; lap ≥ 4t or 40 mm.
  • Complete penetration butt welds are treated as parent metal; joints longer than 150 tt get the long-joint reduction.

Practice questions

Tap a question to see the answer.

1Find the throat and the design strength per mm of an 8 mm shop fillet weld with fusion faces at 90° (fu = 410 N/mm²).

tt = 5.6 mm; fwd = 189.4 N/mm²; 5.6 × 189.4 = 1 060.5 N/mm = 1.06 kN/mm.

2What is the minimum fillet size to join an 8 mm plate to a 25 mm plate, and the largest fillet on the square edge of the 8 mm plate?

Table 21, thicker part 25 mm: 6 mm (less than the 8 mm thinner part, so 6 mm applies); largest on the edge 8 − 1.5 = 6.5 mm.

3A 6 mm fillet weld needs an effective length of 150 mm. How long is it made, and what is the shortest effective length allowed?

150 + 2 × 6 = 162 mm; effective length at least 4 × 6 = 24 mm.

4Find the throat of a 10 mm fillet with fusion faces at 110°.

K = 0.55 (107° to 113°); tt = 0.55 × 10 = 5.5 mm.

5A shop fillet weld has a normal stress of 100 N/mm² and a shear stress of 80 N/mm² (fu = 410 N/mm²). Check the equivalent stress.

fe = √(100² + 3 × 80²) = 170.9 N/mm² ≤ 410/(√3 × 1.25) = 189.4 N/mm²: safe.

6Above what joint length does a side weld with a 6 mm fillet (throat 4.2 mm) need the long-joint reduction?

150 × 4.2 = 630 mm.

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • N. Subramanian, Design of Steel Structures, Oxford University Press, New Delhi, 1st edition, 2008.
  • S. K. Duggal, Limit State Design of Steel Structures, McGraw Hill Education (India), 3rd edition, 2019.
Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.

Sent privately to the Indiacon editor; not published.