3.2 Lug angles and splices
After this lesson you should be able to:
- State why a lug angle is used on an outstanding leg, and write the excess-strength rules of IS 800:2007 cl. 10.12.2 (angles) and cl. 10.12.3 (channels).
- Design a lug angle and its bolts for the force in the outstanding leg of an equal angle, including the whole-area rule of cl. 10.12.6.
- Design a tension splice (cover plates with bolts, or a butt weld) for the greater of the factored tension and 0.3 times the member design capacity in tension (cl. 10.7).
Theory
A single angle bolted through one leg leaves the outstanding leg almost idle at the connection: shear lag cuts the rupture strength (lesson 3.1, cl. 6.3.3) and the load path is eccentric. A lug angle is a short angle fastened to that outstanding leg and to the same gusset, so both legs of the main angle deliver load into the joint. IS 800:2007 cl. 10.12 covers lug angles. Where they are used on an angle member, cl. 10.12.6 lets the designer take the whole area of the angle as effective, notwithstanding the shear-lag rules of Section 6.
For angle members, cl. 10.12.2 sets two excesses on the force in the outstanding leg. The lug angle and its connection to the gusset (or other support) must develop at least 20 percent more than that force; the attachment of the lug to the main angle must develop at least 40 percent more. The force in the outstanding leg is taken in proportion to its area share of the section (outstanding gross area over gross area), which for an equal angle is about half the tension. Cl. 10.12.4 forbids fewer than two bolts, rivets or equivalent welds from the lug to the gusset. Cl. 10.12.5 asks that the effective connection of the lug terminate at the end of the member, and that fastening of the lug to the main preferably start in advance of the direct connection to the gusset, so the outstanding leg is engaged before the connected-leg bolts take load.
For channel members and the like, cl. 10.12.3 uses smaller excesses on the force not taken by the direct (usually web) connection: 10 percent for the lug and its gusset connection, 20 percent for the attachment of the lug to the member. Cl. 10.12.1 asks that lug angles on the outstanding legs of a channel be disposed symmetrically with respect to the section where possible, so the joint does not twist.
A splice joins two lengths of a tension member end to end: cover plates with bolts or welds on each face, or a full-penetration butt weld. Cl. 10.7 says connections that carry design actions (with listed exceptions such as lacings, sag rods, purlins and girts) must transmit the greater of the design action in the member and a stated minimum. For splices in members subjected to axial tension that minimum is a force of at least 0.3 times the member design capacity in tension. So the splice is designed for max(T, 0.3 Td), where Td is the design tensile strength of the member from lesson 3.1. The fasteners themselves are checked by the bolt and weld rules of Section 10 (lessons 2.1 and 2.2). Beam and column splices are pointed to Annex F-2 and F-3 by cl. 10.6.3; this lesson stays with tension-member plate and angle splices and does not quote those annex numbers.
Cover-plate splices place one or two plates over the joint so that the bolts are in double shear when covers sit on both faces. The covers must themselves be strong enough in yielding and rupture for their share of the design force. A full-penetration butt weld is treated as parent metal for strength, so the joint capacity is that of the plate at the weld, provided the weld is sound and the preparation meets the welding clause. Partial-penetration or fillet-only splices are sized from the weld throat rules of lesson 2.2 and are not a substitute for a full-strength butt when the code minimum demands the full design force.
Derivation
- Outstanding-leg force for an angle: F_out = T × Ago/Ag, where Ago is the outstanding gross area (leg width less half the thickness, times thickness) and Ag is the gross area of the angle. For an equal angle Ago ≈ Ag/2, so F_out ≈ T/2.
- Angle lug design forces (cl. 10.12.2): lug and its gusset connection ≥ 1.20 F_out; lug-to-main attachment ≥ 1.40 F_out. Number of bolts n ≥ design force / bolt value, with the bolt value the lesser of shear (cl. 10.3.3) and bearing (cl. 10.3.4), and n ≥ 2 to the gusset (cl. 10.12.4).
- Channel lug design forces (cl. 10.12.3): with F the force not accounted for by the direct connection, lug and gusset connection ≥ 1.10 F; lug-to-member attachment ≥ 1.20 F; preferably a symmetric pair of lugs sharing F.
- Tension-splice design force (cl. 10.7): T_des = max(T, 0.3 Td). For a double-cover bolted splice each bolt is in double shear; bolt value = min(2 Vdsb, Vdbp on the main thickness). Covers: each face takes T_des/2 when two covers share equally; check Ag and An of the covers for yielding and rupture.
- With lug angles on an angle member, Td may be taken with the whole gross and net areas (cl. 10.12.6), so shear-lag reduction of cl. 6.3.3 is not applied; block shear at the end connection is still checked.
Outstanding-leg force: F_out = T × Ago/Ag (kN)Angle lug (IS 800:2007 cl. 10.12.2): lug + gusset ≥ 1.20 F_out; lug to main ≥ 1.40 F_out; at least two fasteners to the gusset (cl. 10.12.4)Channel lug (cl. 10.12.3): lug + gusset ≥ 1.10 F; lug to member ≥ 1.20 F; F = force not taken by the direct connectionWhole area effective with lug angles on an angle (cl. 10.12.6): use Ag and An without the shear-lag cut of cl. 6.3.3Tension splice design force (cl. 10.7): T_des = max(T, 0.3 Td) (kN), Td = design tensile strength of the memberBolt values (lesson 2.1): M20 class 4.6, threads in the shear plane, Vdsb = 45.26 kN single shear; double shear 90.53 kN; bearing Vdbp = 2.5 kb d t fu/γmb with γmb = 1.25
- Static loading. Fatigue connections need the detailing of IS 800 Section 13 and are not covered here.
- Bolt values use standard holes, threads in the shear plane, and the partial factors of Table 5 (γmb = 1.25), consistent with lessons 2.1 and 2.2.
- The outstanding-leg force is taken as T times the outstanding gross-area share; the connected-leg bolts are designed for the remainder of T (and any eccentricity of the joint is checked separately where required by cl. 10.8).
- Steel is E250 (fy = 250, fu = 410 N/mm²) in the examples unless stated; other grades change fy and fu only.
- Section areas given in the examples are taken as given design data (handbook values); the half-thickness convention is used when an outstanding area is computed from leg sizes.
- Cover plates are assumed to share the splice force equally when two identical covers are used.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- IS 800:2007 cl. 10.12.1 (symmetric disposition of lug angles on channel outstanding legs where possible), cl. 10.12.2 (angle members: 20 percent and 40 percent excesses on the outstanding-leg force), cl. 10.12.3 (channel members: 10 percent and 20 percent excesses on the force not taken by the direct connection), cl. 10.12.4 (minimum two fasteners from lug to gusset), cl. 10.12.5 (lug connection terminates at the member end; fastening to the main preferably starts in advance of the direct connection), cl. 10.12.6 (whole area of an angle member effective when lug angles are used).
- IS 800:2007 cl. 10.7 (minimum design action on connections; splices in axial tension designed for at least 0.3 times the member design capacity in tension), cl. 10.6.3 (beam and column splices per Annex F-2 and F-3 — named only), cl. 10.3 (bolt values), cl. 10.5 (welds; butt welds treated as parent metal), Table 5 (γmb = 1.25, γm0 = 1.10, γm1 = 1.25).
- Background: N. Subramanian, Design of Steel Structures, Oxford University Press, 2008; S. K. Duggal, Limit State Design of Steel Structures, McGraw Hill Education (India), 3rd edition, 2019.
- EN 1993-1-8 covers bolts, welds and splices in steel structures, and AISC 360 Chapter J covers similar connection and splice rules. They are named here for comparison, not ranked, and their factor values are not quoted.
Worked examples
Problem. An equal-angle tie ISA 100 × 100 × 10 (Ag = 1 903 mm²), E250 (fy = 250, fu = 410 N/mm²), carries a factored tension T = 280 kN. It is connected through one leg to a 12 mm gusset. Design a lug angle and M20 class 4.6 bolts (threads in the shear plane, Vdsb = 45.26 kN) for the outstanding leg. Take the outstanding gross area as Ago = (100 − 5) × 10 = 950 mm², end distance 40 mm (kb = 40/(3 × 22) = 0.606).
- Outstanding-leg force: F_out = 280 × 950/1 903 = 139.8 kN.
- Lug + gusset (cl. 10.12.2): 1.20 × 139.8 = 167.7 kN. Lug to main: 1.40 × 139.8 = 195.7 kN.
- Bearing on an 8 mm lug: 2.5 × 0.606 × 20 × 8 × 410/1.25 = 79.52 kN > 45.26 kN, so shear governs. Bolts to gusset: 167.7/45.26 = 3.71 → provide 4 (capacity 181.0 kN). Bolts lug to main: 195.7/45.26 = 4.32 → provide 5 (capacity 226.3 kN). Both satisfy the minimum of two fasteners to the gusset (cl. 10.12.4).
- Try lug ISA 100 × 100 × 8 with Ag = 1 536 mm² (leg-area convention (100 + 100 − 8) × 8). Yielding: Tdg = 1 536 × 250/1.10 = 349.1 kN ≥ 167.7 kN. Net connected leg with one 22 mm hole: Anc = (100 − 22 − 4) × 8 = 592 mm²; Tdn = 0.9 × 592 × 410/1.25 = 174.8 kN ≥ 167.7 kN.
- With the lug, the whole main-angle area is effective (cl. 10.12.6). Main yielding: Tdg = 1 903 × 250/1.10 = 432.5 kN ≥ 280 kN. Detail the lug bolts so that fastening to the main starts in advance of the direct connection (cl. 10.12.5).
Answer. Lug ISA 100 × 100 × 8; 4 M20 class 4.6 bolts to the gusset and 5 to the main angle
Problem. A flat plate 200 mm × 12 mm, E250, Ag = 2 400 mm², has design tensile strength Td = Ag fy/γm0 = 545.5 kN (yielding of the gross section; holes are only at the splice). It carries a factored tension T = 420 kN. Design a double-cover bolted splice with M20 class 4.6 bolts (threads in the shear plane) and end distance 40 mm (kb = 0.606).
- Design force (cl. 10.7): T_des = max(420, 0.3 × 545.5) = max(420, 163.6) = 420 kN.
- Double shear: 2 × 45.26 = 90.53 kN. Bearing on the 12 mm main plate: 2.5 × 0.606 × 20 × 12 × 410/1.25 = 119.3 kN. Bolt value = 90.53 kN.
- Bolts each side of the joint: 420/90.53 = 4.64 → provide 5 (capacity 452.6 kN).
- Two cover plates 200 × 8 mm: Ag,covers = 3 200 mm²; Tdg = 3 200 × 250/1.10 = 727.3 kN ≥ 420 kN. With two 22 mm holes across the width on one chain, An,covers = 2 × (200 − 2 × 22) × 8 = 2 496 mm²; Tdn = 0.9 × 2 496 × 410/1.25 = 736.8 kN ≥ 420 kN.
- Check the main plate net section at the first bolt line in the same way, and stagger or add a gauge line if rupture governs over the member Td used above.
Answer. T_des = 420 kN; 5 M20 class 4.6 bolts each side; two 200 × 8 cover plates
Problem. A channel tie connected through its web to a gusset carries a factored tension T = 360 kN. The web bolt group is designed for 240 kN. The remaining F = 120 kN is the force not accounted for by the direct connection (outstanding flanges). Design a symmetric pair of lug angles with M20 class 4.6 bolts (Vdsb = 45.26 kN) by cl. 10.12.3 and cl. 10.12.1.
- Lug + gusset (cl. 10.12.3): 1.10 × 120 = 132 kN. Lug to channel: 1.20 × 120 = 144 kN.
- Two lug angles, one on each outstanding flange, share the force (cl. 10.12.1): each lug + gusset 66 kN; each lug to channel 72 kN.
- Bolts each lug to gusset: 66/45.26 = 1.46 → provide 2 (capacity 90.53 kN), which also meets cl. 10.12.4. Bolts each lug to the channel: 72/45.26 = 1.59 → provide 2 (capacity 90.53 kN).
- Choose lug angles whose own Tdg and Tdn each exceed 66 kN (for example a small equal angle such as ISA 50 × 50 × 6 with Ag about 568 mm² gives Tdg ≈ 129 kN). Start the lug-to-channel fastening in advance of the web connection (cl. 10.12.5).
Answer. Two lug angles, each with 2 M20 class 4.6 bolts to the gusset and 2 to the channel
Step-by-step procedure
- Find the factored tension T and the member design strength Td (lesson 3.1). For a splice, set T_des = max(T, 0.3 Td).
- For a lug on an angle: compute F_out = T × Ago/Ag; design the lug and its gusset connection for 1.20 F_out and the lug-to-main attachment for 1.40 F_out; use at least two fasteners to the gusset.
- For a lug on a channel: find the force F not taken by the direct connection; design for 1.10 F and 1.20 F; prefer a symmetric pair of lugs.
- Select bolt class and diameter; take the bolt value as the lesser of shear and bearing; fix the number of bolts; detail end and pitch distances.
- Check the lug section itself (yielding and rupture) for its design force, and check the main member with the whole area effective when cl. 10.12.6 applies.
- For a cover-plate splice, size the bolts for T_des in the correct shear condition, size the covers for yielding and rupture, and check the main net section at the bolt lines. For a full-penetration butt weld, treat the weld as parent metal and confirm the plate capacity.
Site notes
- Lug angles are common on long truss ties and bracing where a single-leg connection would waste the section; they add fabrication but recover the outstanding-leg capacity.
- Shop drawings must show the lug starting ahead of the main-leg bolts; a lug that stops short of the member end, or that starts level with the first main bolt, misses the intent of cl. 10.12.5.
- A tension splice designed only for the analysis force T can be unsafe when T is small compared with Td: the code floor of 0.3 Td catches under-designed joints in lightly loaded runs of a strong member.
- Double-cover splices need matching holes in both covers and the main plate; drift pins, not erected bolts, are used to align holes so that bolts are not bent on installation.
- Full-penetration butt welds need NDT as specified in the welding procedure; a partial-penetration weld must not be passed off as a full-strength splice.
- Designing the lug for F_out with no 20 percent or 40 percent excess (cl. 10.12.2), or using the channel excesses on an angle.
- Using only one bolt from the lug to the gusset (forbidden by cl. 10.12.4).
- Still applying the shear-lag reduction of cl. 6.3.3 after lug angles have been provided (cl. 10.12.6 makes the whole angle area effective).
- Designing a tension splice for T alone when 0.3 Td is larger (cl. 10.7).
- Taking double-shear bolt values when only one cover plate is used, or ignoring bearing on the thinner ply.
- Placing both channel lug angles on the same flange, so the joint is not symmetric (cl. 10.12.1).
For an equal-angle lug, F_out ≈ T/2; design the gusset connection for about 0.6 T and the lug-to-main attachment for about 0.7 T (the 1.20 and 1.40 factors on half the load). In Example 1, 0.6 × 280 = 168 kN and 0.7 × 280 = 196 kN, matching 167.7 kN and 195.7 kN. For any tension splice, always compare T with 0.3 Td before sizing fasteners.
Summary
- Lug angles engage the outstanding leg; on an angle, design for 1.20 F_out to the gusset and 1.40 F_out to the main (cl. 10.12.2), with at least two fasteners to the gusset (cl. 10.12.4).
- On a channel, design for 1.10 F and 1.20 F on the force not taken by the direct connection, preferably with symmetric lugs (cl. 10.12.1, 10.12.3).
- With lug angles on an angle member, the whole area is effective (cl. 10.12.6).
- Tension splices are designed for max(T, 0.3 Td) (cl. 10.7); cover-plate bolts use the shear and bearing values of Section 10.
- Detail the lug so its fastening to the main starts in advance of the direct connection (cl. 10.12.5).
Practice questions
Tap a question to see the answer.
1An equal angle carries T = 200 kN and has Ago/Ag = 0.50. Find the lug-to-gusset and lug-to-main design forces by cl. 10.12.2.
F_out = 100 kN; lug + gusset ≥ 120 kN; lug to main ≥ 140 kN.
2How many M20 class 4.6 bolts (45.26 kN) are needed for a lug-to-gusset force of 120 kN, and does that meet cl. 10.12.4?
120/45.26 = 2.65 → 3 bolts; yes, at least two.
3A tension member has Td = 500 kN and T = 100 kN. What force is the splice designed for?
max(100, 0.3 × 500) = max(100, 150) = 150 kN.
4A double-cover splice uses M20 class 4.6 bolts (double shear 90.53 kN) for T_des = 300 kN. Bearing does not govern. Find the number of bolts each side.
300/90.53 = 3.31 → 4 bolts each side.
5A channel has F = 80 kN not taken by the web connection. Two symmetric lug angles share F. Find the design force for each lug-to-gusset connection.
1.10 × 80 = 88 kN total; each lug 44 kN.
6Why may the whole area of an angle be used once lug angles are provided?
Cl. 10.12.6: with lug angles connecting an angle member, the whole area is taken as effective, notwithstanding Section 6.
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- N. Subramanian, Design of Steel Structures, Oxford University Press, New Delhi, 1st edition, 2008.
- S. K. Duggal, Limit State Design of Steel Structures, McGraw Hill Education (India), 3rd edition, 2019.