8.2 Gantry girders
After this lesson you should be able to:
- Explain what a gantry (crane runway) girder carries: moving wheel loads with impact, lateral surge and longitudinal traction, as listed in IS 800:2007 cl. 3.5.3 and IS 875 (Part 2):1987 cl. 6.0.
- Compute the maximum wheel load from crane data and apply the IS 875 (Part 2) cl. 6.3 allowances for vertical impact, transverse surge and longitudinal traction.
- Find the maximum bending moment and shear in a simply supported gantry girder under two moving wheel loads using the influence-line position rule.
- Check a given section for biaxial bending with the conservative linear form allowed in IS 800:2007 cl. 9.3.1.1, and for deflection against a stated limit from Table 6.
Theory
A gantry girder (crane runway girder) spans between columns of an industrial shed and carries the rail on which an electric overhead travelling (EOT) or hand-operated crane runs. The crane bridge spans across the bay between two such rails; a crab (trolley) travels along the bridge carrying the hook load. The gantry girder therefore sees concentrated wheel loads that move along its span, not a fixed distributed load.
IS 800:2007 treats crane loads as imposed loads (cl. 3.2.1). Clause 3.5.3 lists the crane effects to be included: vertical wheel loads, eccentricity effects of those loads, impact factors, lateral surge across the rail and longitudinal thrust along the rail, with surge and longitudinal thrust not acting simultaneously. Clause 3.5.4 sets combination rules for one or more cranes, and cl. 3.5.6 asks for runway girders that support bumpers to be checked for bumper impact as specified by the crane manufacturer.
The allowances themselves come from IS 875 (Part 2):1987 cl. 6.3. For EOT crane girders the vertical load is increased by 25 percent of the maximum static wheel loads (a smaller allowance applies to hand-operated cranes). The transverse (surge) force is a percentage of the weight of the crab plus the lifted load — 10 percent for EOT cranes with a rigid mast such as stripper cranes, and 5 percent for other EOT cranes and hand-operated cranes — shared equally among the wheels on one rail. Longitudinal traction is 5 percent of the static wheel loads. Clause 6.4 then states that surge and traction are not taken together, except that with only one crane in the bay they may act together with the vertical loads.
Maximum wheel load occurs when the crab, with full hook load, is at its closest approach to one rail. The reaction at that rail is half the bridge self-weight plus the share of (hook load + crab) found by statics on the crane span. Dividing by the number of wheels at that end gives the static wheel load P.
For two equal loads P at spacing c moving across a simply supported span L, the absolute maximum moment occurs under one load when the mid-span point bisects the distance between that load and the resultant of the pair. The load is then at L/2 − c/4 from the near support and Mmax = P (2L − c)² / (8L). If c is large (c > 0.586L), a single wheel at mid-span (PL/4) gives more, so both are compared. Maximum shear occurs with one wheel just at a support.
The section is usually a rolled or built-up I-section, often with a channel or plate on the top flange so that the top flange can resist the lateral surge moment as a horizontal beam. Major-axis bending comes from vertical loads, minor-axis bending of the top flange from surge, and torsion from rail eccentricity. Gantry girders are rarely laterally restrained along the span, so lateral-torsional buckling is checked to cl. 8.2.2.
Serviceability governs often: excessive vertical or lateral deflection makes cranes run badly and damages rails. IS 800:2007 Table 6 gives separate gantry deflection limits that tighten as crane operation and capacity increase; the limit for a project is read from that table for the crane type. Fatigue (Section 13) matters for heavily used cranes and is named here only.
Derivation
- Crane bridge span Lc, minimum hook approach a, bridge weight Wb, crab weight Wc, hook load W. Rmax = Wb/2 + (W + Wc)(Lc − a)/Lc.
- Static wheel load P = Rmax / n, where n is the number of wheels at that end. With vertical impact (EOT): P_i = 1.25 P.
- Two loads P at spacing c, resultant midway between them. Place load 1 at x from support A so that mid-span bisects load 1 and the resultant: x = L/2 − c/4.
- Reaction RB = P[x + (x + c)]/L; moment under load 1, M = RA·x = P(2L − 2x − c)x/L. Substituting x = (2L − c)/4 gives Mmax = P(2L − c)²/(8L).
- Maximum shear: load 1 at support A, load 2 at c: V = P + P(L − c)/L.
- Lateral surge per wheel H = s (W + Wc)/n_rail with s = 0.05 or 0.10 per IS 875 (P2) cl. 6.3; lateral moment uses the same position rule: My = H(2L − c)²/(8L).
Rmax = Wb/2 + (W + Wc)(Lc − a)/Lc; P = Rmax/nEOT vertical impact (IS 875 P2 cl. 6.3): P_i = 1.25 PSurge (other EOT, hand): H_total = 0.05(W + Wc) per rail; rigid-mast EOT 0.10(W + Wc)Longitudinal traction: 0.05 × static wheel loads on the railTwo moving loads: Mmax = P(2L − c)²/(8L) (if c ≤ 0.586L); else PL/4Vmax = P(2 − c/L)Conservative section check (cl. 9.3.1.1, N = 0): Mz/Mdz + My/Mdy ≤ 1.0; Md = Zp fy/γm0, γm0 = 1.10Two symmetric loads P at a from each end: δ = P a (3L² − 4a²)/(24 E I)
- Crane data (bridge weight, crab weight, hook approach, wheel base) are given design data that would come from the crane supplier; IS 800 cl. 3.2.1.1 directs equipment loads to manufacturers’ data.
- Gantry girder simply supported between brackets; self-weight of girder and rail taken as a given UDL.
- Partial safety factor 1.5 used for crane (imposed) and dead loads in the strength examples, as one combination from IS 800 Table 4; a real design checks all combinations.
- Section moduli and second moment of area are given design data for a built-up section (I-section with top channel), not a handbook section.
- Lateral-torsional buckling moment Md,LT is given design data assumed to have been computed per cl. 8.2.2.
- Deflection limit used in Example 2 is stated as design data; the governing limit is read from IS 800:2007 Table 6 for the crane type.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- IS 800:2007 cl. 3.2.1 (crane load is an imposed load), 3.2.1.1 (equipment loads from manufacturers’ data), 3.5.3 (crane effects to include), 3.5.4 (crane load combinations), 3.5.6 (bumper impact), 3.9.3.3 (bracing for high-speed cranes), 4.3.6.3 (notional sway in gantry load case), 8.2.2 (laterally unsupported beams), 9.3.1.1 (section strength under combined actions), Table 4 (partial safety factors), Table 5 (γm0 = 1.10), Table 6 (deflection limits including gantry rows).
- IS 875 (Part 2):1987 cl. 6.0 (crane loads under imposed loads), 6.3 (impact allowances for crane girders: vertical, transverse and longitudinal), 6.4 (crane load combinations; surge and traction not simultaneous).
- IS 807 named for crane classification only. EN 1993-6 (crane supporting structures) and AISC Design Guide 7 (industrial buildings) are named for comparison; each code is applied within its own system.
Worked examples
Problem. An EOT crane (not rigid-mast) has hook capacity W = 200 kN, crab weight Wc = 50 kN, bridge weight Wb = 200 kN, crane span Lc = 16 m between rails and minimum hook approach a = 1.2 m. Two wheels at each end, wheel base c = 3.2 m. The gantry girder spans L = 6.0 m (simply supported); girder plus rail self-weight 2.0 kN/m (given). Find the maximum wheel load with impact, the factored maximum moment and shear (γf = 1.5 for both crane and dead load in this combination), and the factored lateral surge moment.
- Rmax = 200/2 + (200 + 50)(16 − 1.2)/16 = 100 + 250 × 0.925 = 100 + 231.25 = 331.25 kN.
- Static wheel load P = 331.25 / 2 = 165.625 kN ≈ 165.6 kN.
- With 25 percent vertical impact (IS 875 P2 cl. 6.3): P_i = 1.25 × 165.625 = 207.03 kN; factored Pu = 1.5 × 207.03 = 310.55 kN.
- c = 3.2 m ≤ 0.586L = 3.516 m, so the two-wheel position governs: Mmax = Pu(2L − c)²/(8L) = 310.55 × (12 − 3.2)²/48 = 310.55 × 1.6133 = 501.0 kN·m (single wheel at mid-span would give 310.55 × 6/4 = 465.8 kN·m).
- Self-weight factored: 1.5 × 2.0 × 6²/8 = 13.5 kN·m. Design Mz ≈ 501.0 + 13.5 = 514.5 kN·m (adding the two maxima is slightly conservative).
- Shear: Vu = Pu(2 − c/L) = 310.55 × (2 − 0.5333) = 455.5 kN; plus self-weight 1.5 × 2.0 × 6/2 = 9.0 kN, so Vu ≈ 464.5 kN.
- Surge (5 percent, cl. 6.3): total on one rail 0.05 × (200 + 50) = 12.5 kN; per wheel 6.25 kN; factored 9.375 kN. My = 9.375 × 1.6133 = 15.13 kN·m on the top flange.
Answer. P = 165.6 kN static, 207.0 kN with impact; Mz ≈ 514.5 kN·m, Vu ≈ 464.5 kN, My ≈ 15.1 kN·m
Problem. Use the actions of Example 1. A built-up section (I-section with a channel on the top flange, fy = 250 MPa, plastic and compact) has given design data: Zpz = 3.20 × 10⁶ mm³; top-flange-plus-channel plastic modulus about the vertical axis Zpy,f = 0.75 × 10⁶ mm³; Iz = 6.50 × 10⁸ mm⁴; lateral-torsional buckling resistance Md,LT = 620 kN·m (from cl. 8.2.2, given). Check section strength with the conservative linear form of cl. 9.3.1.1, check Mz against Md,LT, and check service deflection under the static wheel loads (no impact) placed symmetrically about mid-span, against an illustrative limit L/750 stated as design data. E = 2 × 10⁵ N/mm².
- Mdz = Zpz fy/γm0 = 3.20 × 10⁶ × 250 / 1.10 = 727.3 kN·m.
- Mdy (top flange) = 0.75 × 10⁶ × 250 / 1.10 = 170.5 kN·m.
- Section check (N = 0): 514.5/727.3 + 15.13/170.5 = 0.707 + 0.089 = 0.796 ≤ 1.0, OK.
- Buckling: Mz = 514.5 kN·m ≤ Md,LT = 620 kN·m (ratio 0.830), OK; with the surge term added in the same linear way, 0.830 + 0.089 = 0.919 ≤ 1.0.
- Deflection: wheels P = 165.625 kN at a = (6.0 − 3.2)/2 = 1.4 m from each support. δ = P a (3L² − 4a²)/(24 E I) = 165 625 × 1 400 × (3 × 6 000² − 4 × 1 400²)/(24 × 2 × 10⁵ × 6.5 × 10⁸) = 7.44 mm.
- Illustrative limit L/750 = 6 000/750 = 8.0 mm; 7.44 mm ≤ 8.0 mm, OK (confirm the actual limit in IS 800 Table 6 for the crane type).
Answer. Interaction 0.796 (section), 0.919 (with buckling); δ = 7.44 mm ≤ 8.0 mm
Step-by-step procedure
- Get crane data from the supplier: capacity, crab and bridge weights, crane span, hook approach, wheel base, number of wheels, class (IS 807) and whether rigid-mast.
- Compute maximum static wheel load; apply vertical impact, surge and traction allowances from IS 875 (Part 2) cl. 6.3, and the combinations of IS 800 cl. 3.5.4 and IS 875 (P2) cl. 6.4.
- Find maximum moment and shear with moving-load positions; add self-weight of girder and rail.
- Choose a trial section (I-section, often with a top channel or plate); check section strength (cl. 9.3.1.1), lateral-torsional buckling (cl. 8.2.2), shear, web bearing and buckling under wheel loads.
- Check vertical and lateral deflection against Table 6 for the crane type; check fatigue for heavily used cranes (Section 13, named).
- Detail rail fixing, end stops and bumpers (cl. 3.5.6), bracket connections and bracing (cl. 3.9.3.3).
Site notes
- Check rail alignment and level against the drawings before the crane is commissioned; misaligned rails cause crabbing and extra surge.
- Tighten rail clips and holding-down bolts to the specified sequence; recheck after the first weeks of crane use.
- Do not let the crane run on an incomplete runway; end stops must be fixed before travel trials.
- Inspect welds at top-flange-to-web junctions and stiffener ends regularly for fatigue cracks.
- Lifting and erection of gantry girders and cranes is high-risk work: follow the approved lifting plan and the instructions of a competent supervisor. This lesson is educational and is not a site method statement.
- Using the hook capacity alone as the wheel load and forgetting bridge and crab self-weight.
- Applying impact to the surge force or to foundations where IS 875 (P2) cl. 6.3 does not ask for it.
- Taking surge and longitudinal traction together when there is more than one crane in the bay (cl. 6.4 note).
- Using PL/4 for two wheels when the two-wheel position (P(2L − c)²/8L) governs, or vice versa when c is large.
- Ignoring lateral-torsional buckling because the girder “looks stocky”; gantry girders are seldom restrained along the span.
- Checking deflection with factored loads instead of service wheel loads, or using a building beam limit instead of the gantry row in Table 6.
Wheel load from crane statics; +25% vertical impact for EOT girders, surge 5% (10% rigid-mast) of crab + hook, traction 5% of wheel loads (IS 875 P2 cl. 6.3). Two moving loads: Mmax = P(2L − c)²/8L. Check biaxial strength (IS 800 cl. 9.3.1.1), LTB (cl. 8.2.2) and Table 6 deflection.
Summary
- Gantry girders carry moving crane wheel loads with impact, lateral surge and longitudinal traction (IS 800 cl. 3.5.3; IS 875 Part 2 cl. 6.0 and 6.3).
- The maximum wheel load comes from the crab at its closest hook approach; impact on EOT crane girders is 25 percent of the maximum static loads.
- For two equal wheels at spacing c, Mmax = P(2L − c)²/(8L) when c ≤ 0.586L.
- The top flange (often strengthened with a channel) resists surge as a horizontal beam; check combined bending with cl. 9.3.1.1 and buckling with cl. 8.2.2.
- Deflection limits for gantries are in IS 800 Table 6 and depend on crane operation and capacity. With this lesson, the Steel Design textbook is complete.
Practice questions
Tap a question to see the answer.
1An EOT crane has W = 150 kN, crab 40 kN, bridge 160 kN, crane span 14 m, hook approach 1.0 m, two wheels each end. Find the static maximum wheel load.
Rmax = 80 + 190 × 13/14 = 80 + 176.43 = 256.43 kN; P = 128.2 kN.
2What vertical impact allowance does IS 875 (Part 2) cl. 6.3 give for EOT crane girders?
25 percent of the maximum static wheel loads.
3Two wheels of 100 kN at 3.0 m spacing cross a 7 m simply supported girder. Find Mmax.
c = 3.0 ≤ 0.586 × 7 = 4.10 m; Mmax = 100 × (14 − 3)²/56 = 216.1 kN·m.
4For a non-rigid-mast EOT crane with crab 40 kN and hook load 150 kN, what is the total surge on one rail?
0.05 × 190 = 9.5 kN, shared equally among the wheels on that rail.
5May lateral surge and longitudinal traction be combined when two cranes run in the same bay?
No; IS 875 (P2) cl. 6.4 note — they are taken separately; only with a single crane in the bay may they act together.
6Why is a channel often welded on the top flange of a gantry girder?
To give the top flange enough lateral bending strength and stiffness for surge, and to improve lateral-torsional buckling resistance.
7Which IS 800:2007 table gives deflection limits for gantry girders?
Table 6 (gantry rows depend on crane operation and capacity).
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- N. Subramanian, Design of Steel Structures, Oxford University Press, New Delhi, 1st edition, 2008.
- S. K. Duggal, Limit State Design of Steel Structures, McGraw Hill Education (India), 3rd edition, 2019.