5.3 Introduction to plate girders
After this lesson you should be able to:
- Explain what a plate girder is, why its web is made deep and thin, and why shear buckling of the web, not yielding, usually controls the web design.
- Check the minimum web thickness of IS 800:2007 cl. 8.6.1.1 (with εw from Amendment No. 1) for a web with and without intermediate transverse stiffeners, and know when cl. 8.4.2.1 asks for a shear buckling check (d/tw > 67εw for an unstiffened web).
- Compute the shear buckling strength of a web panel by the simple post-critical method of cl. 8.4.2.2(a) (Kv, τcr,e, λw, τb, Vcr, Vd) and carry out the basic checks on an intermediate transverse stiffener under cl. 8.7.1.2, 8.7.1.5, 8.7.2.5 and 8.7.2.6.
Theory
When the bending moment on a beam is larger than the biggest rolled section can carry, or the span is long enough that a rolled section would deflect too much, designers build the section from plates. A plate girder is an I-section made by welding (or, in older work, riveting or bolting) two flange plates to a deep web plate. Road and railway bridges, crane girders, transfer girders in buildings and heavy industrial floors use them. IS 800:2007 covers them in cl. 8.6, Design of Beams and Plate Girders with Solid Webs, together with the shear rules of cl. 8.4, the stiffened web panel rules of cl. 8.5 and the stiffener design rules of cl. 8.7. This lesson closes Chapter 5 by introducing those ideas; lessons 5.1 and 5.2 covered bending of laterally supported and unsupported beams.
The shape follows from first principles. Bending is resisted mainly by the flanges: the moment capacity is roughly the flange force times the lever arm, Af fy × hf. Making the girder deeper increases the lever arm, so the same moment needs less flange area. The web mainly carries shear and keeps the flanges apart, and the shear stress in a deep web is low. So the economical girder is deep, with a thin web. The catch is that a thin plate in shear buckles: the diagonal compression in each web panel makes it wrinkle long before the steel yields.
Shear in a web panel produces principal tension along one diagonal and principal compression along the other. A thin plate under that compression buckles in a series of inclined waves, like a sheet of paper pushed along its edges. Plate theory gives the elastic critical shear stress τcr,e = Kv π² E / [12 (1 − μ²) (d / tw)²], where d is the web depth, tw its thickness, μ = 0.3 is Poisson’s ratio (Section 2) and Kv is a buckling coefficient that depends on the panel shape. IS 800:2007 cl. 8.4.2.2(a) gives Kv = 5.35 when transverse stiffeners are provided only at the supports, Kv = 4.0 + 5.35 / (c/d)² for c/d < 1.0 and Kv = 5.35 + 4.0 / (c/d)² for c/d ≥ 1.0, where c is the stiffener spacing. Closer stiffeners make squarer or narrower panels, raise Kv and raise the buckling stress.
When does buckling matter? Cl. 8.4.2.1 asks for the shear buckling check when d/tw exceeds 67ε for a web without stiffeners (Amendment No. 1 substitutes εw and fyw, the web yield stress, in that clause), and gives a separate, higher trigger for a web with stiffeners that rises with Kv. Below that, the web reaches plastic shear Vp = Av fyw / √3 (cl. 8.4.1), with Av = d tw for a welded I-section bent about its major axis (cl. 8.4.1.1). For E250 steel εw = √(250 / fyw) = 1.0, so a web deeper than 67 times its thickness must be checked for buckling. Typical plate girder webs have d/tw between about 100 and 250, so the check is the normal case.
The simple post-critical method of cl. 8.4.2.2(a) can be used for I-section girder webs with or without intermediate transverse stiffeners, provided the web has transverse stiffeners at the supports. The nominal shear strength is Vn = Vcr = Av τb. The shear buckling stress τb comes from a non-dimensional web slenderness λw = √[fyw / (√3 τcr,e)]: τb = fyw / √3 when λw ≤ 0.8 (the web yields in shear first); τb = [1 − 0.8 (λw − 0.8)] (fyw / √3) when 0.8 < λw < 1.2 (a straight transition); and τb = fyw / (√3 λw²) when λw ≥ 1.2, which is simply the elastic critical stress τcr,e. The design shear strength is Vd = Vn / γm0 with γm0 = 1.10 (cl. 8.4, Table 5).
A stiffened web does not collapse when it buckles. The buckled panel keeps carrying extra shear by a diagonal tension band anchored by the flanges and the stiffeners, rather like the diagonals of a Pratt truss. Cl. 8.4.2.2(b), the tension field method, allows this reserve for webs that have intermediate transverse stiffeners in addition to the support stiffeners, with c/d ≥ 1.0, provided the adjacent panels or the end posts can anchor the tension field. The resistance is then Vtf, which adds a tension-field term to the buckling part and may not exceed Vp. Cl. 8.5 then sets rules for the end panels and end posts that anchor it. Because the anchorage design is lengthy, this introductory lesson uses only the simple post-critical method in its numbers; the tension field method is named so the reader knows the extra capacity exists.
A web that is very thin can also be a problem in service, even when its strength is adequate: it can breathe (flex in and out) under repeated loads, distort during welding and handling, and look wavy. Cl. 8.6.1.1, the serviceability requirement for minimum web thickness, therefore limits d/tw directly. With no transverse stiffeners and the web connected to flanges along both longitudinal edges, d/tw ≤ 200εw (90εw if connected along one edge only). With only transverse stiffeners: d/tw ≤ 200εw when 3d ≥ c ≥ d; c/tw ≤ 200εw when 0.74d ≤ c < d; and d/tw ≤ 270εw when c < 0.74d (the 0.74d wording is from Amendment No. 1). If c > 3d the web is treated as unstiffened. A second longitudinal stiffener at the neutral axis, with the first one, allows d/tw ≤ 400εw. Here εw = √(250 / fyw).
A second minimum-thickness rule, cl. 8.6.1.2, prevents the compression flange from buckling into the web. When a girder bends, the curved compression flange presses down on the web; a very thin web can fold under it. That limit depends on the flange yield stress through εf (Amendment No. 1 defines εf = √(250 / fyf)) and is relaxed when transverse stiffeners are spaced closer than 1.5d. Both cl. 8.6.1.1 and cl. 8.6.1.2 must be met; the final web thickness is the larger of the two requirements and the shear strength need.
Stiffeners are the plate girder’s tool kit. Cl. 8.7.1.1 lists six kinds: intermediate transverse web stiffeners to raise the shear buckling strength (cl. 8.7.2), load carrying stiffeners to stop local buckling of the web under concentrated loads (cl. 8.7.3), bearing stiffeners to stop local crushing of the web (cl. 8.7.4), torsion stiffeners for torsional restraint at supports (cl. 8.7.9), diagonal stiffeners for local reinforcement under shear and bearing (cl. 8.7.7) and tension stiffeners to carry tension applied through a flange into the web (cl. 8.7.8). One stiffener may do more than one job and must then satisfy every rule. Their outstand from the web face should not exceed 20 tq ε unless the outer edge is stiffened, and when it lies between 14 tq ε and 20 tq ε the design uses a core section with 14 tq ε outstand (cl. 8.7.1.2). The buckling resistance Fqd uses fcd of a strut on curve c (cl. 7.1.2.1) with an effective section of the stiffener plus web up to 20 tw each side of its centreline, and an effective length of 0.7 L for intermediate stiffeners (cl. 8.7.1.5).
The flanges and web must work as one section. Cl. 8.6.3.3 requires the flange-to-web welds (or rivets or bolts) to carry the horizontal shear produced by the bending-moment gradient plus any vertical load applied directly to the flange, and, where the tension field method is used, the tension field stress in the web. From first principles that horizontal shear per unit length is the shear flow q = V Af ȳ / I, where Af ȳ is the first moment of the flange about the neutral axis. The web’s effective area is its full depth times thickness (cl. 8.6.4.1). EN 1993-1-5 (plated structural elements) and AISC 360 (Chapter G, shear) cover the same behaviour with their own notation and calibration; this lesson follows IS 800:2007 and names them only for comparison, without ranking them or quoting their values.
Derivation
- Plate buckling in shear (thin-plate theory): τcr,e = Kv π² E / [12 (1 − μ²) (d / tw)²], with Kv from the panel aspect ratio c/d (cl. 8.4.2.2(a)).
- Define web slenderness by the ratio of shear yield to elastic buckling stress: λw = √[(fyw / √3) / τcr,e] = √[fyw / (√3 τcr,e)].
- Design curve: τb = fyw / √3 (λw ≤ 0.8); τb = [1 − 0.8 (λw − 0.8)] (fyw / √3) (0.8 < λw < 1.2); τb = fyw / (√3 λw²) = τcr,e (λw ≥ 1.2).
- Simple post-critical strength: Vn = Vcr = Av τb with Av = d tw (welded I); Vd = Vn / γm0.
- Bending of the girder: Md ≈ Af fy hf / γm0 shows why depth is economical; shear flow at the flange–web junction q = V Af ȳ / I gives the weld demand (cl. 8.6.3.3).
- Intermediate stiffener force (cl. 8.7.2.5): Fq = V − Vcr / γm0 ≤ Fqd; when the web alone carries V by the simple post-critical method, Fq is zero or negative.
Shear buckling check needed (cl. 8.4.2.1): d/tw > 67εw for a web without stiffeners; εw = √(250 / fyw)Vp = Av fyw / √3; Av = d tw (welded I, major axis); Vd = Vn / γm0, γm0 = 1.10 — Nτcr,e = Kv π² E / [12 (1 − μ²) (d / tw)²] (N/mm²); Kv = 5.35 (supports only); 4.0 + 5.35/(c/d)² (c/d < 1.0); 5.35 + 4.0/(c/d)² (c/d ≥ 1.0)λw = √[fyw / (√3 τcr,e)]; τb = fyw/√3 (λw ≤ 0.8); [1 − 0.8(λw − 0.8)] fyw/√3 (0.8 < λw < 1.2); fyw/(√3 λw²) (λw ≥ 1.2)Vcr = Av τb (simple post-critical method, cl. 8.4.2.2(a))Minimum web thickness, serviceability (cl. 8.6.1.1): unstiffened d/tw ≤ 200εw (both edges), 90εw (one edge); transverse stiffeners only: d/tw ≤ 200εw (3d ≥ c ≥ d), c/tw ≤ 200εw (0.74d ≤ c < d), d/tw ≤ 270εw (c < 0.74d); c > 3d treated as unstiffenedStiffener outstand (cl. 8.7.1.2): ≤ 20 tq ε; core section 14 tq ε when outstand is between 14 tq ε and 20 tq εIntermediate stiffener: Fq = V − Vcr/γm0 ≤ Fqd (cl. 8.7.2.5); Fqd from fcd, curve c, web 20 tw each side, KL = 0.7 L (cl. 8.7.1.5); web connection shear ≥ tw² / (5 bs) kN/mm with tw, bs in mm (cl. 8.7.2.6)E = 2 × 10⁵ N/mm²; μ = 0.3 (Section 2)
- Welded doubly symmetric I-girder bent about its major axis; web connected to both flanges along both longitudinal edges.
- E250 steel for web and stiffeners, fyw = fy = 250 N/mm², so ε = εw = 1.0; γm0 = 1.10.
- Transverse stiffeners at both supports (required for the simple post-critical method); intermediate stiffeners, where used, are equally spaced and on both sides of the web.
- Shear checked without tension field action; flange contribution to shear ignored. Bending, lateral-torsional buckling and combined high shear with bending follow lessons 5.1, 5.2 and Section 9.
- Plate sizes and forces are idealised design data; welds, root gaps and corrosion allowance are ignored.
- Compression flange buckling into the web (cl. 8.6.1.2), minimum stiffener second moment of area (cl. 8.7.2.4) and end-panel design (cl. 8.5) are named but not computed in this introduction.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- IS 800:2007 cl. 8.4, 8.4.1 and 8.4.1.1 (Vd = Vn / γm0, plastic shear Vp, shear area Av = d tw for welded I-sections).
- IS 800:2007 cl. 8.4.2.1 (when shear buckling must be checked; Amendment No. 1 substitutes εw and fyw) and cl. 8.4.2.2(a) simple post-critical method (Kv, τcr,e, λw, τb, Vcr); cl. 8.4.2.2(b) tension field method (named).
- IS 800:2007 cl. 8.5 and 8.5.1 (stiffened web panels and end panels, named).
- IS 800:2007 cl. 8.6, 8.6.1.1 (serviceability minimum web thickness, Amendment No. 1: εw and c < 0.74d), 8.6.1.2 (compression flange buckling requirement, named), 8.6.3.3 (flange-to-web connection), 8.6.4.1 (effective web area).
- IS 800:2007 cl. 8.7.1.1 (stiffener types), 8.7.1.2 (outstand; Amendment No. 1 wording), 8.7.1.5 (buckling resistance of stiffeners), 8.7.2.5 (stiffener force) and 8.7.2.6 (connection to web); cl. 7.1.2.1 (fcd, curve c).
- IS 800:2007 Section 2 (E = 2 × 10⁵ N/mm², μ = 0.3) and Table 5 (γm0 = 1.10).
- For comparison only: EN 1993-1-5 and AISC 360 Chapter G. Not ranked; no values quoted.
Worked examples
Problem. A welded plate girder has a web depth d = 1 500 mm connected to flanges along both edges, E250 (fyw = 250 N/mm², εw = 1.0). (a) Check a 8 mm web. (b) The designer wants to save steel with a 6 mm web: check it without intermediate stiffeners, and find a stiffener spacing c that satisfies cl. 8.6.1.1.
- (a) tw = 8 mm: d/tw = 1 500 / 8 = 187.5.
- Cl. 8.4.2.1: 187.5 > 67εw = 67, so the web must be checked for shear buckling (Example 2).
- Cl. 8.6.1.1(a), no transverse stiffeners: limit 200εw = 200; 187.5 ≤ 200 — serviceability satisfied without intermediate stiffeners.
- (b) tw = 6 mm: d/tw = 1 500 / 6 = 250 > 200 — not allowed as an unstiffened web.
- Stiffeners at 3d ≥ c ≥ d (1 500 to 4 500 mm): the limit is still d/tw ≤ 200, so 250 fails.
- Stiffeners at 0.74d ≤ c < d, i.e. 1 110 ≤ c < 1 500 mm: c/tw ≤ 200 → c ≤ 200 × 6 = 1 200 mm. So c from 1 110 to 1 200 mm works; for example c = 1 150 mm gives c/tw = 191.7 ≤ 200.
- Stiffeners at c < 0.74d = 1 110 mm: d/tw ≤ 270εw = 270; 250 ≤ 270 — satisfied, for example with c = 1 000 mm.
- Web area falls from 1 500 × 8 = 12 000 mm² to 1 500 × 6 = 9 000 mm², a 25 percent saving in web steel, paid for by stiffeners and their welding. The 6 mm web must still pass the shear strength check and cl. 8.6.1.2.
Answer. tw = 8: d/tw = 187.5 ≤ 200, no intermediate stiffeners needed for serviceability; tw = 6: d/tw = 250, needs stiffeners at c ≤ 1 200 mm (c/tw ≤ 200) or c < 1 110 mm (d/tw ≤ 270)
Problem. The 1 500 × 8 mm web of Example 1(a) carries a factored shear V = 1 150 kN near the support. E = 2 × 10⁵ N/mm², μ = 0.3, fyw = 250 N/mm², γm0 = 1.10. Find Vd by cl. 8.4.2.2(a) for (i) stiffeners at the supports only, (ii) intermediate stiffeners at c = 1 500 mm and (iii) at c = 750 mm.
- Av = d tw = 1 500 × 8 = 12 000 mm². Upper bound Vp = 12 000 × 250 / √3 = 1 732.1 kN; Vp / γm0 = 1 574.6 kN.
- Common factor: π² E / [12 (1 − 0.3²) (187.5)²] = 1.974 × 10⁶ / (10.92 × 35 156) = 5.142 N/mm².
- (i) Kv = 5.35: τcr,e = 5.35 × 5.142 = 27.51 N/mm²; λw = √[250 / (√3 × 27.51)] = 2.291 ≥ 1.2, so τb = 250 / (√3 × 2.291²) = 27.51 N/mm² (equal to τcr,e). Vcr = 12 000 × 27.51 = 330.1 kN; Vd = 330.1 / 1.10 = 300.1 kN < 1 150 kN — fails.
- (ii) c/d = 1.0: Kv = 5.35 + 4.0 / 1.0² = 9.35; τcr,e = 48.07 N/mm²; λw = 1.733 ≥ 1.2; τb = 48.07 N/mm²; Vcr = 576.9 kN; Vd = 524.5 kN < 1 150 kN — fails.
- (iii) c/d = 0.5: Kv = 4.0 + 5.35 / 0.5² = 25.40; τcr,e = 25.40 × 5.142 = 130.6 N/mm²; λw = √[250 / (√3 × 130.6)] = 1.051, between 0.8 and 1.2.
- τb = [1 − 0.8 (1.051 − 0.8)] × 250 / √3 = 0.799 × 144.34 = 115.3 N/mm²; Vcr = 12 000 × 115.3 = 1 383.9 kN; Vd = 1 383.9 / 1.10 = 1 258.1 kN ≥ 1 150 kN — OK (utilisation 0.91).
- Stiffeners at half the web depth raise the shear strength more than four times over the unstiffened web. A tension field design (cl. 8.4.2.2(b)) could allow wider spacing, but needs the anchorage checks of cl. 8.5.
Answer. Vd = 300.1 kN (supports only), 524.5 kN (c = d), 1 258.1 kN (c = 0.5d, λw = 1.051, τb = 115.3 N/mm²) ≥ 1 150 kN
Problem. For case (iii) of Example 2, intermediate stiffeners are a pair of 100 × 10 mm flats (E250), one on each side of the 8 mm web, length L = d = 1 500 mm, no external load. Check the outstand (cl. 8.7.1.2), the stiffener force (cl. 8.7.2.5), the buckling resistance Fqd (cl. 8.7.1.5, curve c α = 0.49) and the web connection shear (cl. 8.7.2.6).
- Outstand bs = 100 mm; 20 tq ε = 20 × 10 × 1.0 = 200 mm ≥ 100 — OK. 14 tq ε = 140 mm ≥ 100, so the full stiffener section is effective (no core section needed).
- Stiffener force Fq = V − Vcr / γm0 = 1 150 − 1 258.1 = −108.1 kN: the web carries the shear on its own, so there is no axial demand from shear; the stiffener’s job is to hold the panel boundaries straight.
- Effective section (cl. 8.7.1.5): stiffeners 2 × 100 × 10 = 2 000 mm² plus web 20 tw each side = 40 × 8 × 8 = 2 560 mm²; A = 4 560 mm².
- I about the web centreline: 10 × 208³ / 12 − 10 × 8³ / 12 + 320 × 8³ / 12 = 7.512 × 10⁶ mm⁴; r = √(7.512 × 10⁶ / 4 560) = 40.59 mm.
- KL = 0.7 × 1 500 = 1 050 mm; KL / r = 25.87; λ = 25.87 / [π √(2 × 10⁵ / 250)] = 0.291.
- Curve c: φ = 0.5 [1 + 0.49 (0.291 − 0.2) + 0.291²] = 0.565; χ = 1 / [0.565 + √(0.565² − 0.291²)] = 0.954; fcd = 0.954 × 250 / 1.10 = 216.7 N/mm².
- Fqd = 4 560 × 216.7 = 988.3 kN, far above Fq — OK.
- Connection to web: shear per stiffener component ≥ tw² / (5 bs) = 8² / (5 × 100) = 0.128 kN/mm; a pair of small continuous fillet welds easily provides this.
Answer. Outstand 100 ≤ 200 mm (full section); Fq = −108.1 kN (no shear demand); A = 4 560 mm², r = 40.59 mm, λ = 0.291, fcd = 216.7 N/mm², Fqd = 988.3 kN; connection ≥ 0.128 kN/mm
Step-by-step procedure
- Choose girder depth from bending and deflection (a deeper girder needs less flange area), then flange area from Md ≈ Af fy hf / γm0 (lessons 5.1 and 5.2).
- Pick a trial web thickness and check cl. 8.6.1.1 (d/tw ≤ 200εw unstiffened) and cl. 8.6.1.2; decide whether intermediate transverse stiffeners are worth providing.
- Check d/tw against 67εw (cl. 8.4.2.1); if exceeded, compute Kv, τcr,e, λw, τb and Vcr = Av τb (cl. 8.4.2.2(a)); check V ≤ Vd = Vcr / γm0.
- If Vd is short, close up the stiffeners, thicken the web, or use the tension field method of cl. 8.4.2.2(b) with the end-panel checks of cl. 8.5.
- Size intermediate stiffeners: outstand (cl. 8.7.1.2), stiffener force and buckling (cl. 8.7.2.5, 8.7.1.5), minimum stiffness (cl. 8.7.2.4) and web connection (cl. 8.7.2.6).
- Provide bearing and load carrying stiffeners at supports and under concentrated loads (cl. 8.7.3, 8.7.4); design flange-to-web welds for the shear flow (cl. 8.6.3.3).
Site notes
- Thin webs distort with welding heat; specify a welding sequence and check web flatness tolerances before the stiffeners are fitted.
- Cl. 8.6.3.5 limits the gap between web and flange plates before fillet welding to 1 mm; check fit-up on site, because a gap reduces the effective throat.
- Bearing stiffeners over supports must be fitted (or welded) tight to the loaded flange; a stiffener that does not touch the flange does not carry the reaction.
- Web splices and service cut-outs should not sit at the points of maximum shear or under heavy concentrated loads (cl. 8.6.4.2).
- Handle long plate girders with lifting beams and temporary bracing; an unstiffened web panel can be dented by slings or by stacking.
- Assuming the plastic shear Vp = Av fyw / √3 for a deep web without checking d/tw against 67εw; for slender webs the buckling strength can be a fraction of Vp.
- Using Kv = 5.35 + 4.0/(c/d)² for panels with c/d below 1.0 (that range uses 4.0 + 5.35/(c/d)²), or forgetting that Kv = 5.35 applies when stiffeners are only at the supports.
- Applying the simple post-critical method to a web with no stiffeners at the supports; cl. 8.4.2.2(a) requires support stiffeners.
- Checking only cl. 8.6.1.1 and forgetting the compression flange buckling requirement of cl. 8.6.1.2, or using ε of the flange where εw of the web is required (Amendment No. 1).
- Making a stiffener outstand larger than 20 tq ε, or using the full section when the outstand exceeds 14 tq ε (a core section is needed).
- Using the tension field method without anchorage: the end panel and end post must be designed for it (cl. 8.5).
- Mixing kN and N in Vcr = Av τb (N/mm² × mm² gives N).
Quick plate girder web check (E250): d/tw up to 67 → no shear buckling; up to 200 → serviceability is fine without intermediate stiffeners; above 200 → stiffeners required (d/tw up to 270 if c < 0.74d). For shear strength, a stiffener spacing near half the web depth typically lifts the web from elastic buckling into the transition range.
Summary
- A plate girder is a built-up I-section: deep for bending economy, with a thin web that is governed by shear buckling.
- Shear buckling check when d/tw > 67εw (unstiffened). Simple post-critical method: τcr,e = Kv π² E / [12(1 − μ²)(d/tw)²]; λw = √[fyw / (√3 τcr,e)]; τb in three ranges; Vcr = Av τb; Vd = Vcr / γm0.
- Kv = 5.35 (supports only); 4.0 + 5.35/(c/d)² (c/d < 1); 5.35 + 4.0/(c/d)² (c/d ≥ 1). Closer stiffeners raise Kv and Vcr.
- Minimum web thickness (cl. 8.6.1.1): 200εw unstiffened; with transverse stiffeners 200εw (d ≤ c ≤ 3d), c/tw ≤ 200εw (0.74d ≤ c < d), 270εw (c < 0.74d); plus the flange-buckling rule of cl. 8.6.1.2.
- Stiffeners (cl. 8.7): intermediate, load carrying, bearing, torsion, diagonal, tension; outstand ≤ 20 tq ε; buckling on curve c with 20 tw of web each side; Fq = V − Vcr/γm0.
- Tension field action (cl. 8.4.2.2(b), cl. 8.5) adds post-buckling capacity when the panels are anchored; flange-to-web welds carry the shear flow (cl. 8.6.3.3).
Practice questions
Tap a question to see the answer.
1A welded girder web is 1 200 × 10 mm, E250. Is a shear buckling check needed, and does it satisfy cl. 8.6.1.1 without intermediate stiffeners?
d/tw = 120 > 67, so the shear buckling check is needed; 120 ≤ 200, so serviceability is satisfied without intermediate stiffeners.
2Find Kv for stiffeners only at the supports, and for c/d = 0.8 and c/d = 1.5.
Supports only: 5.35. c/d = 0.8: 4.0 + 5.35 / 0.64 = 12.36. c/d = 1.5: 5.35 + 4.0 / 2.25 = 7.13.
3For a web with d/tw = 120 and Kv = 5.35 (E250, μ = 0.3), find τcr,e, λw and τb.
τcr,e = 5.35 × π² × 2 × 10⁵ / (10.92 × 120²) = 67.15 N/mm²; λw = √[250 / (√3 × 67.15)] = 1.466 ≥ 1.2; τb = 250 / (√3 × 1.466²) = 67.15 N/mm².
4A 1 800 mm deep web of E250 steel is to be 7 mm thick. What range of stiffener spacing satisfies cl. 8.6.1.1?
d/tw = 257.1 > 200, so stiffeners are needed. 0.74d = 1 332 mm. c/tw ≤ 200 gives c ≤ 1 400 mm, so 1 332 ≤ c ≤ 1 400 mm works; any c < 1 332 mm works because 257.1 ≤ 270.
5What is the maximum outstand of a 12 mm thick E250 stiffener, and above what outstand must a core section be used?
20 tq ε = 240 mm maximum; above 14 tq ε = 168 mm the design uses a core section with 168 mm outstand.
6Find the minimum web-connection shear for an intermediate stiffener of outstand 120 mm on a 10 mm web.
tw² / (5 bs) = 100 / 600 = 0.167 kN/mm per stiffener component.
7Why does the simple post-critical method need stiffeners at the supports?
The method relies on the web panel edges at the supports being held straight so the panel can develop its buckling strength; without support stiffeners the end of the web is free to distort and the reaction would also crush or buckle it.
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- N. Subramanian, Design of Steel Structures, Oxford University Press, New Delhi, 1st edition, 2008.
- S. K. Duggal, Limit State Design of Steel Structures, McGraw Hill Education (India), 3rd edition, 2019.