7.1 Isolated footings
After this lesson you should be able to:
- Size an isolated column footing from the service load and the safe bearing capacity, including the effect of a moment on the base pressure.
- Locate the critical sections of IS 456:2000 cl. 34 for bending, one-way shear and two-way (punching) shear, and check each with factored loads.
- Design and detail the bottom mesh, including the central band of a rectangular footing, check development length, and check load transfer by bearing from the column into the footing.
Theory
A column carries its load to the ground through a footing: a slab of reinforced concrete that spreads a large force over enough soil to keep the pressure within what the ground can safely carry. Seen upside down, a footing is a short, thick cantilever slab loaded by the soil pushing up and held by the column at its centre. The soil pressure bends it so that the bottom face is in tension, which is why the main steel is a mesh near the bottom.
Two quite separate questions are answered in turn. The first is geotechnical: how big must the footing be? It is answered with service (unfactored) loads plus an allowance for the footing and soil above it, compared with the safe bearing capacity of the soil, because bearing capacity values are themselves working values with their own margin. The second is structural: how thick must the slab be and how much steel does it need? This is answered at the limit state of collapse with factored loads, but only the net upward pressure from the column load is used, because the weight of the footing and the soil above it is carried straight down to the soil without bending the slab.
IS 456:2000 cl. 34.2.3.1 takes the bending moment at a section as the moment of all the soil pressure on one side of a vertical plane cut right across the footing, and cl. 34.2.3.2 (a) puts the critical plane at the face of a concrete column. Shear is checked in two ways under cl. 34.2.4.1: as a wide beam, with the critical section at one effective depth d from the face for footings on soil (the distance set by Amendment No. 1; it is d/2 for footings on piles), and as two-way action, where a truncated pyramid tries to punch through, checked by the flat-slab rules of cl. 31.6 on a perimeter at d/2 from the column face. In most footings the punching check decides the depth, and the depth is normally chosen so that no shear reinforcement is needed.
The steel is spread as cl. 34.3.1 directs: uniformly across the full width in each direction for square footings and for the long bars of a rectangular one. For the short bars of a rectangular footing, a fraction 2/(β + 1) of the total, where β is the ratio of the long side to the short side, is placed in a central band as wide as the footing, and the rest in the two outer strips, because the zone near the column is stiffer and attracts more of the moment. The bars must be anchored: cl. 34.2.4.3 makes the bending sections also the sections for development length.
Finally the column load has to get into the footing. Cl. 34.4 allows the concrete under the column to carry a bearing stress of 0.45 fck multiplied by the square root of A1/A2, but not by more than 2, where A2 is the loaded area and A1 the largest area of the footing that is geometrically similar to it within a frustum spreading at one vertical to two horizontal. Any excess is carried by column bars or dowels (cl. 34.4.1 to 34.4.3), and in every case at least 0.5 per cent of the column area, with a minimum of four bars, crosses the joint.
Derivation
- Area: the soil must carry the column load P plus the footing and backfill, often taken as about 10 per cent of P for a first estimate. Required area A = 1.1 P / q_safe, and for a square footing the side is the square root of A, rounded up to a practical size.
- Net upward pressure for design: qu = Pu / A, with Pu = 1.5 P for dead plus imposed load (cl. 36.4.1, Table 18). The self-weight is left out because it produces no bending in the slab.
- Moment at the column face for a footing of width B with projection a beyond the face: the pressure on the strip outside the face is qu B a, acting at a/2, so Mu = qu B a²/2.
- One-way shear at a distance d from the face: the soil pressure beyond that section is Vu = qu B (a − d), and τv = Vu / (B d) is compared with τc from Table 19 at the steel ratio provided (lesson 3.1).
- Two-way shear: for a square column of side c the critical perimeter is the square of side c + d, so b0 = 4 (c + d) and the shear is the pressure outside it, Vu = qu (A − (c + d)²). τv = Vu / (b0 d) must not exceed ks τc with τc = 0.25 √fck and ks = 0.5 + βc ≤ 1 (cl. 31.6.3.1; lesson 5.3).
- For a moment M with axial load W on a footing of length L along the moment and width B, the pressure varies linearly: q = W/(B L) ± 6M/(B L²). The minimum stays positive (no lift-off) as long as e = M/W ≤ L/6.
Required area: A = 1.1 P / q_safe (m²; P in kN, q_safe in kN/m²)Net factored pressure: qu = Pu / A (kN/m²)Moment at the column face: Mu = qu B a²/2 (kN m; a = projection beyond the face in m)One-way shear at d from the face: Vu = qu B (a − d); τv = Vu/(B d) (N/mm²)Punching: b0 = 4 (c + d) for a square column; Vu = qu [A − (c + d)²]; τv = Vu/(b0 d) ≤ ks 0.25 √fck (N/mm²)Central band (rectangular footing, short bars): fraction in the band = 2/(β + 1), β = long side / short sideBearing at the column base: allowed stress = 0.45 fck √(A1/A2), with √(A1/A2) ≤ 2 (N/mm²)Development length: Ld = φ (0.87 fy)/(4 τbd) (mm), as in lesson 3.2Pressure with moment: q = W/(B L) ± 6 M/(B L²) (kN/m²), valid while e = M/W ≤ L/6
- The footing is rigid compared with the soil, so the soil pressure is uniform under a concentric load and linear under a moment. On sand the real pressure is higher at the centre and on clay higher at the edges; the rigid assumption is the accepted design model.
- The safe bearing capacity is given by the geotechnical engineer and already allows for settlement; this lesson does not derive it.
- The footing and backfill weight is taken as 10 per cent of the column load in the examples; a deep footing with heavy backfill needs a direct calculation.
- The two layers of the bottom mesh have slightly different effective depths; the examples use the mean depth for both directions, which is the usual first design.
- Limits: footings on piles (where IS 456 treats each pile reaction as a point load at the pile centre), footings with tension under part of the base, sloped footings (cl. 34.1.1) and footings under masonry walls are not worked here.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- IS 456:2000 cl. 34.1 (footings designed for the loads and induced reactions, with settlement as uniform as possible and the safe bearing capacity not exceeded; it points to IS 1904), cl. 34.1.1 (sloped or stepped footings act as a unit), cl. 34.1.2 (edge thickness at least 150 mm for footings on soils and at least 300 mm above the tops of piles).
- IS 456:2000 cl. 34.2.3.1 and 34.2.3.2 (bending moment across the whole footing at the face of the column, pedestal or wall), cl. 34.2.4.1 (one-way shear at d from the face for footings on soils, as amended by Amendment No. 1, and two-way shear by cl. 31.6), cl. 34.2.4.3 (development length checked at the bending sections and at abrupt changes of section).
- IS 456:2000 cl. 34.3 and 34.3.1 (distribution of tensile steel, including the central band 2/(β + 1) for rectangular footings), cl. 34.4, 34.4.1, 34.4.2 and 34.4.3 (load transfer by bearing at 0.45 fck times √(A1/A2) not more than 2; dowels or extended bars of at least 0.5 per cent of the column area and at least four bars, dowel diameter not more than 3 mm above the column bar), cl. 34.4.4 (bars above 36 mm in compression dowelled with smaller bars), cl. 34.5.1 (minimum steel and spacing as for solid slabs, 0.12 per cent of the gross section for high-strength deformed bars, lesson 5.1) and cl. 34.5.2 (360 mm² per metre each way on each face for sections thicker than 1 m).
- IS 456:2000 cl. 26.4.2.2 (minimum cover 50 mm for footings), cl. 26.2.1 (development length), cl. 31.6.1, 31.6.2.1 and 31.6.3.1 (punching perimeter at d/2, nominal stress V/(b0 d), and ks τc with τc = 0.25 √fck), cl. 36.4.1 (partial safety factors for loads, Table 18), Table 19 (cl. 40.2.1) for one-way shear; IS 1904 for foundations in soils; IS 1786 for deformed bars.
- Indian, European and American practice are listed side by side and not ranked: the European concrete code (EN 1992-1-1) checks pad footings for bending and for punching on a control perimeter set at a multiple of the effective depth, with the soil side handled by the geotechnical code EN 1997-1; the American code (ACI 318) has a foundations chapter that checks one-way shear at d from the face and two-way shear at d/2, with the footing area chosen from service loads. Their factors and perimeters differ and are not reproduced here.
Worked examples
Problem. A 400 mm × 400 mm column carries a service load of 1 200 kN (dead plus imposed). The safe bearing capacity is 200 kN/m². Use M25 concrete for the footing and column, Fe 415 bars, and a 600 mm thick flat footing. Design the footing.
- Area: A = 1.1 × 1 200/200 = 6.60 m², side = √6.60 = 2.57 m. Adopt 2.6 m × 2.6 m (6.76 m²).
- Net factored pressure: Pu = 1.5 × 1 200 = 1 800 kN; qu = 1 800/6.76 = 266.3 kN/m².
- Effective depth with 50 mm cover and 16 mm bars in two layers: d = 600 − 50 − 16 = 534 mm (mean of the two layers).
- Punching: the perimeter at d/2 is a square of side 400 + 534 = 934 mm, so b0 = 3 736 mm. Vu = 266.3 × (6.76 − 0.934²) = 266.3 × 5.888 = 1 567.7 kN. τv = 1 567 700/(3 736 × 534) = 0.79 N/mm². With βc = 1, ks = 1.0 and τc = 0.25 × √25 = 1.25 N/mm²: safe.
- Bending at the face: projection a = (2 600 − 400)/2 = 1 100 mm. Mu = 266.3 × 2.6 × 1.1²/2 = 418.8 kN m. Steel: Ast = 0.5 × 25/415 × [1 − √(1 − 4.6 × 418.8 × 10⁶/(25 × 2 600 × 534²))] × 2 600 × 534 = 2 233 mm², more than the minimum 0.0012 × 2 600 × 600 = 1 872 mm². Provide 12 bars of 16 mm each way (2 413 mm²) at about 225 mm centres.
- One-way shear at d from the face: the section is 1 100 − 534 = 566 mm from the edge. Vu = 266.3 × 2.6 × 0.566 = 391.8 kN; τv = 391 800/(2 600 × 534) = 0.28 N/mm². pt = 100 × 2 413/(2 600 × 534) = 0.174 per cent, so τc from Table 19 for M25 is 0.31 N/mm²: safe.
- Development length of 16 mm bars (M25, deformed): Ld = 16 × 0.87 × 415/(4 × 1.4 × 1.6) = 645 mm. Available from the face: 1 100 − 50 = 1 050 mm: enough.
- Bearing: stress under the column = 1 800 000/(400 × 400) = 11.25 N/mm². A frustum at 1 vertical to 2 horizontal from the column would reach 400 + 4 × 600 = 2 800 mm, larger than the footing, so A1 is the whole base and √(A1/A2) = √(6.76/0.16) = 6.5, limited to 2. Allowed = 0.45 × 25 × 2 = 22.5 N/mm²: no dowels needed for bearing, but at least 0.5 per cent of the column area (800 mm², four bars minimum) must still cross the joint, normally the column bars themselves.
Answer. 2.6 m × 2.6 m × 600 mm, 12 bars of 16 mm each way; punching τv 0.79 ≤ 1.25 and one-way τv 0.28 ≤ 0.31 N/mm²; bearing 11.25 ≤ 22.5 N/mm²
Problem. A 300 mm × 500 mm column carries a service load of 800 kN. Safe bearing capacity 150 kN/m², footing M20, column M25, Fe 415. Space limits the footing to 2.0 m wide; use 3.0 m long so that the projections are 0.85 m and 1.25 m, and a depth of 550 mm. Design the steel.
- Area needed = 1.1 × 800/150 = 5.87 m²; 2.0 × 3.0 = 6.0 m² is enough. Pu = 1 200 kN; qu = 1 200/6.0 = 200 kN/m². d = 550 − 50 − 16 = 484 mm.
- Long direction: Mu = 200 × 2.0 × 1.25²/2 = 312.5 kN m, Ast = 1 864 mm² (minimum 0.0012 × 2 000 × 550 = 1 320 mm²). Provide 10 bars of 16 mm (2 011 mm²) spread uniformly across the 2.0 m width.
- One-way shear in the long direction: Vu = 200 × 2.0 × (1.25 − 0.484) = 306.4 kN, τv = 306 400/(2 000 × 484) = 0.32 N/mm². pt = 100 × 2 011/(2 000 × 484) = 0.208 per cent, τc (M20) = 0.33 N/mm²: just safe. With 9 bars it would fail, so the shear check, not bending, fixes the bar count.
- Short direction: Mu = 200 × 3.0 × 0.85²/2 = 216.8 kN m, Ast = 1 264 mm², less than the minimum 0.0012 × 3 000 × 550 = 1 980 mm², so 1 980 mm² is used. β = 3.0/2.0 = 1.5, and the central band of 2.0 m takes 2/(1.5 + 1) = 0.8 of it: 1 584 mm², provided as 15 bars of 12 mm (1 696 mm²). The remaining 396 mm² goes in the two 0.5 m outer strips: 2 bars of 12 mm in each (452 mm² in all). Total 19 bars of 12 mm (2 149 mm²).
- Punching: perimeter (300 + 484) by (500 + 484) = 784 mm by 984 mm, b0 = 3 536 mm. Vu = 200 × (6.0 − 0.784 × 0.984) = 1 045.7 kN; τv = 0.61 N/mm². βc = 300/500 = 0.6 gives ks = 1.1, taken as 1.0; τc = 0.25 × √20 = 1.12 N/mm²: safe.
- Anchorage: Ld for 16 mm bars in M20 = 752 mm, available 1 250 − 50 = 1 200 mm; for 12 mm bars Ld = 564 mm, available 850 − 50 = 800 mm. Bearing: 1 200 000/(300 × 500) = 8.0 N/mm² against 0.45 × 20 × 2 = 18.0 N/mm² on the M20 footing: safe.
Answer. 2.0 m × 3.0 m × 550 mm; long bars 10 of 16 mm across the width; short bars 15 of 12 mm in the central 2.0 m band and 2 of 12 mm in each outer strip
Problem. A 400 mm square column carries a service load of 800 kN and a service moment of 120 kN m about one axis. Safe bearing capacity 200 kN/m². Check a 2.4 m square footing and a 2.4 m × 2.8 m footing (2.8 m along the moment), and find the design moment at the column face for the one that works (factored loads 1 200 kN and 180 kN m, M25, d = 534 mm).
- Total service load with 10 per cent for the footing and soil: W = 880 kN; e = 120/880 = 0.136 m.
- 2.4 m square: q max = 880/5.76 + 6 × 120/2.4³ = 152.8 + 52.1 = 204.9 kN/m², more than 200: not acceptable.
- 2.4 m × 2.8 m: q = 880/6.72 ± 6 × 120/(2.4 × 2.8²) = 130.95 ± 38.27, so 169.2 and 92.7 kN/m². Both are within 0 and 200 kN/m², and e = 0.136 m is less than L/6 = 0.467 m.
- Factored net pressures: 1 200/6.72 ± 6 × 180/(2.4 × 2.8²) = 178.6 ± 57.4, so 236.0 kN/m² at the heavy edge and 121.2 kN/m² at the light edge.
- At the column face, 1.2 m from the heavy edge, the pressure is 236.0 − (236.0 − 121.2) × 1.2/2.8 = 186.8 kN/m². The moment of the trapezium of pressure about the face, over the 2.4 m width: Mu = 2.4 × [186.8 × 1.2²/2 + (236.0 − 186.8) × 1.2²/3] = 379.4 kN m.
- Ast = 2 022 mm² (minimum 0.0012 × 2 400 × 600 = 1 728 mm²): provide 11 bars of 16 mm (2 212 mm²) along the 2.8 m direction, spread across the 2.4 m width.
Answer. 2.4 m square fails (204.9 kN/m²); 2.4 m × 2.8 m gives 169.2 and 92.7 kN/m² at service; design moment 379.4 kN m at the face, 11 bars of 16 mm
Step-by-step procedure
- Get the service load and moment at the column base and the safe bearing capacity from the soil report.
- Add about 10 per cent for the footing and backfill and find the area; with a moment, choose the length along the moment so that the maximum pressure is within the safe value and e ≤ L/6.
- Find the net factored pressure (or the trapezium of pressure with a moment).
- Choose the depth for punching shear at d/2 (cl. 31.6), keeping the edge at least 150 mm (cl. 34.1.2).
- Compute the moment at the column face in each direction and the steel, not less than 0.12 per cent of the gross section; place the short bars of a rectangular footing with the central band.
- Check one-way shear at d from the face with τc at the steel provided; add bars or depth if needed.
- Check development length from the face, and bearing at the column base; provide dowels or extended column bars (at least 0.5 per cent and four bars).
- Detail with 50 mm cover, a lean concrete blinding layer, and starter bars tied in position before the pour.
Site notes
- Excavate to the level in the drawings and inspect the bearing stratum before blinding; soft pockets are dug out and filled with lean concrete, not with loose soil.
- Bottom steel sits on proper cover blocks of at least 50 mm; bars resting on the soil or blinding rust and lose bond.
- Column starter bars must be held exactly in position with templates and ties; a starter shifted by 50 mm changes the column cover and its capacity.
- Footings are poured in one go; a horizontal joint through a footing cuts the punching cone.
- Backfill in layers and compact, and keep the footing from drying out for the full curing period.
- Sizing the footing with factored loads, or designing the steel with service loads.
- Including the footing self-weight in the net pressure used for bending and shear.
- Checking one-way shear at d/2, or punching at d; the two sections are the other way round for footings on soil.
- Spreading the short bars of a rectangular footing uniformly instead of using the central band.
- Forgetting that a moment can push the edge pressure above the safe value even when the average is fine.
A rough first depth for a square column footing on medium soil is about one fifth of the footing width, then confirmed by the punching check. In Example 1 that gives 2 600/5 = 520 mm, close to the 600 mm used.
Summary
- The footing area comes from service loads and the safe bearing capacity; the thickness and steel come from factored net pressure.
- Bending is taken at the column face (cl. 34.2.3.2), one-way shear at d from the face and punching at d/2 (cl. 34.2.4.1, cl. 31.6).
- Short bars of a rectangular footing put 2/(β + 1) of the steel in the central band (cl. 34.3.1).
- Bars are anchored from the face, and the column load is transferred by bearing at up to 0.45 fck × 2 with at least 0.5 per cent dowels (cl. 34.4).
- With a moment, keep e ≤ L/6 and the edge pressure within the safe value.
Practice questions
Tap a question to see the answer.
1A column carries 1 500 kN at service on soil with a safe bearing capacity of 250 kN/m². Find the side of a square footing, allowing 10 per cent for self-weight.
A = 1.1 × 1 500/250 = 6.6 m²; side = 2.57 m, adopt 2.6 m.
2For a 3.0 m × 2.0 m footing, what fraction of the short-direction steel goes in the central band?
β = 1.5; 2/(1.5 + 1) = 0.8, so 80 per cent.
3Where is the critical section for one-way shear in a footing on soil, and where for punching?
One-way shear at d from the face (cl. 34.2.4.1 (a), as amended); punching on a perimeter at d/2 from the face (cl. 31.6.1).
4Find the factored moment at the face of a 300 mm column on a 2.1 m square footing with qu = 250 kN/m².
a = 0.9 m; Mu = 250 × 2.1 × 0.9²/2 = 212.6 kN m.
5What is the largest bearing stress allowed on an M30 footing under a column when A1/A2 is large?
0.45 × 30 × 2 = 27 N/mm².
6A footing carries W = 1 000 kN and M = 200 kN m with L = 3.0 m along the moment. Is there tension under the base?
e = 0.2 m < L/6 = 0.5 m, so the whole base stays in compression.
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- S. U. Pillai, D. Menon, Reinforced Concrete Design, Tata McGraw Hill (now McGraw Hill Education (India)), 3rd edition, 2009.
- P. C. Varghese, Limit State Design of Reinforced Concrete, Prentice Hall of India (PHI Learning), 2nd edition, 2008.
- J. K. Wight, J. G. MacGregor, Reinforced Concrete: Mechanics and Design, Pearson, 6th edition, 2012.
- R. Park, T. Paulay, Reinforced Concrete Structures, John Wiley and Sons, 1975.