Indiacon CivilSubscribe

Textbook › Steel Design › Chapter 5 › Lesson 5.1

5.1 Laterally supported beams

Steel Design Chapter 5: Beams Under review — not yet three-checked Author: Indiacon

Learning objectives

After this lesson you should be able to:

  • State when a beam may be treated as laterally supported under IS 800:2007 cl. 8.2.1, and why that route uses the section moduli rather than an LTB reduction.
  • Compute design bending strength Md = βb Zp fy / γm0 with the 1.2 Ze fy / γm0 (simply supported) or 1.5 Ze fy / γm0 (cantilever) service cap of cl. 8.2.1.2 when V ≤ 0.6 Vd.
  • Find plastic shear resistance Vp = Av fyw / √3 and Vd = Vp / γm0 for a hot-rolled I-section (Av = h tw, cl. 8.4.1.1), decide low shear versus high shear (V ≷ 0.6 Vd), and show how βb drops Md for a semi-compact section.

Theory

A floor beam with a concrete slab on its top flange, or a beam with closely spaced lateral braces to the compression flange, does not buckle sideways between supports in the same way as a slender unbraced girder. IS 800:2007 cl. 8.2 separates the two cases. When the member is adequately restrained against lateral torsional buckling it is a laterally supported beam (cl. 8.2.1) and the design bending strength is governed by the yield of the cross-section. When it is not so restrained, cl. 8.2.2 brings in lateral torsional buckling and a reduced Md. This lesson stays with the restrained case; the next lesson treats the unrestrained one.

Cl. 8.2.1 says a beam may be assumed adequately supported at the supports when the compression flange has full lateral restraint and the supports also give nominal torsional restraint — for example from web cleats, partial-depth end plates, fin plates or continuity into the next span. Full lateral restraint to the compression flange along the span may come from a connected floor slab or from discrete braces. Cl. 8.1 reminds the designer that members in predominant bending must resist bending, shear and concentrated forces, meet the deflection limits of Section 5, and, when axial force or biaxial bending is also present, follow Section 9. Cl. 8.1.1 takes the effective span as the centre-to-centre distance of the supports, unless the reaction is assumed eccentric, in which case the span is measured between the assumed lines of reaction.

Laterally supported beamfloor slab (lateral restraint)wuSimply supported + restrainedPlastic vs elastic modulusZpZeMdVIndiacon original, not to scale
Figure 5.1: Simply supported I-beam with a floor slab restraining the compression flange, beside plastic (Zp) and elastic (Ze) stress blocks with Md and V check arrows. Indiacon original, not to scale.

For a laterally supported beam the basic check is M ≤ Md (cl. 8.2). When the factored shear V does not exceed 0.6 Vd, cl. 8.2.1.2 gives Md = βb Zp fy / γm0. Here Zp and Ze are the plastic and elastic section moduli of the cross-section, fy is the design yield stress, and γm0 = 1.10 from Table 5 for resistance governed by yielding. The factor βb is 1.0 for plastic and compact sections (Table 2 classification) and Ze/Zp for semi-compact sections. Semi-compact flanges or webs cannot form a plastic stress block before local buckling, so the code replaces Zp with Ze through βb.

The same clause caps Md to avoid irreversible deformation under service loads: Md shall be less than 1.2 Ze fy / γm0 for simply supported beams and 1.5 Ze fy / γm0 for cantilevers. In practice the designer computes βb Zp fy / γm0 and then takes the smaller of that value and the service cap. Plastic and compact I-beams often have Zp / Ze around 1.12 to 1.15, so the 1.2 Ze cap rarely bites for simply supported spans; it matters more when Zp / Ze is larger or when a cantilever uses the 1.5 factor.

Shear is checked through Section 8.4. Cl. 8.4.1 gives the nominal plastic shear resistance under pure shear as Vn = Vp, with Av the shear area and fyw the yield stress of the web. With the von Mises plastic shear stress fy / √3, Vp = Av fyw / √3, and the design shear strength is Vd = Vn / γm0. For hot-rolled I and channel sections bent about the major axis, cl. 8.4.1.1 takes Av = h tw (overall depth times web thickness); for welded I-sections the corresponding product is d tw. If V ≤ Vd the web is strong enough in plastic shear; if also V ≤ 0.6 Vd the bending formula of cl. 8.2.1.2 may be used without a high-shear reduction.

When V exceeds 0.6 Vd, cl. 8.2.1.3 requires a reduced design bending strength. Cl. 9.2.1 states the same 60 percent threshold in Section 9 language: below it, Md from cl. 8.2 needs no reduction; above it, cl. 9.2.2 asks for the moment capacity under high shear. The algebraic reduction mixes plastic moduli and the shear ratio; the OCR of those coefficients on the box is not reliable enough to quote, so this lesson only names the path — apply the high-shear rules of cl. 8.2.1.3 and cl. 9.2.2, or choose a stockier web so that V falls back below 0.6 Vd.

Two further detailing checks sit beside Md. Cl. 8.2.1.4 deals with holes in the tension flange: their effect on design bending strength may be ignored when the clause’s net-to-gross flange check is satisfied; otherwise the reduced flange area enters the modulus. Cl. 8.2.1.5 allows shear lag in wide flanges to be disregarded when the outstand width b0 is not more than L0/20 and the internal flange width bi is not more than L0/10, with L0 the distance between points of zero moment. Amendment No. 1 (January 2012) also clarifies cl. 8.2.1.1: substitute d/tw > 67ε for the earlier d/tw ≤ 67ε wording, so a web with d/tw greater than 67ε is the case treated as susceptible to shear buckling before yielding and is designed with the matching rules rather than the simple plastic Vp path alone.

EN 1993-1-1 (Class 1–3 cross-sections and the M–V interaction) and AISC 360 (compact and noncompact flexural members with Cb lateral-torsional modifiers when unbraced) cover the same physics with different notation. This lesson follows IS 800:2007 and names those documents only for comparison; it does not rank them or quote their values.

Derivation

  1. Low shear (cl. 8.2.1.2): Md0 = βb Zp fy / γm0. βb = 1.0 (plastic or compact); βb = Ze / Zp (semi-compact).
  2. Service cap: Md ≤ 1.2 Ze fy / γm0 (simply supported) or 1.5 Ze fy / γm0 (cantilever). Adopt Md = min(Md0, cap).
  3. Shear area, hot-rolled I major axis (cl. 8.4.1.1): Av = h tw.
  4. Plastic shear (cl. 8.4.1): Vp = Av fyw / √3; Vd = Vp / γm0. Low-shear bending applies while V ≤ 0.6 Vd.
  5. High shear (cl. 8.2.1.3, cl. 9.2.1–9.2.2): when V > 0.6 Vd, reduce Md by the code high-shear rules (coefficients not reproduced here).
  6. Factored actions on a simply supported span with uniform load wu: Mu = wu L² / 8, Vu = wu L / 2, with L the effective span (cl. 8.1.1).
Formulas, symbols and SI units
  • Low shear: Md = βb Zp fy / γm0 ≤ 1.2 Ze fy / γm0 (simply supported) or 1.5 Ze fy / γm0 (cantilever) (cl. 8.2.1.2)
  • βb = 1.0 (plastic, compact); βb = Ze / Zp (semi-compact)
  • Vp = Av fyw / √3; Vd = Vp / γm0; low shear when V ≤ 0.6 Vd (cl. 8.4.1, cl. 8.2.1.2)
  • Hot-rolled I, major-axis Av = h tw (cl. 8.4.1.1)
  • γm0 = 1.10 (Table 5); E250: fy = fyw = 250 N/mm²
  • Simply supported UDL: Mu = wu L² / 8; Vu = wu L / 2
Assumptions and limits
  • Beam is laterally supported per cl. 8.2.1 (compression flange restrained; supports give nominal torsion); LTB is outside this lesson.
  • Examples use E250 steel with thickness in the range where fy = 250 N/mm²; γm0 = 1.10.
  • Section class (plastic, compact or semi-compact) is given design data — Table 2 limits are not re-derived here.
  • Web is not susceptible to shear buckling before yielding for the plastic Vp path (d/tw not greater than 67ε in the Amend No.1 sense); high shear still checked via V / Vd.
  • Section dimensions and moduli are idealised given design data (root fillets ignored).
  • No axial force; combined axial and bending follows Section 9 beyond the high-shear note.

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • IS 800:2007 cl. 8.1 (general) and cl. 8.1.1 (effective span of beams).
  • IS 800:2007 cl. 8.2 (design strength in bending) and cl. 8.2.1 (laterally supported beam).
  • IS 800:2007 cl. 8.2.1.2 (Md for V ≤ 0.6 Vd; βb; 1.2 Ze / 1.5 Ze service caps), cl. 8.2.1.3 (high shear), cl. 8.2.1.4 (holes in tension flange), cl. 8.2.1.5 (shear lag limits).
  • IS 800:2007 Amendment No. 1 (January 2012) to cl. 8.2.1.1: d/tw > 67ε marks webs susceptible to shear buckling before yielding.
  • IS 800:2007 cl. 8.4, cl. 8.4.1 (plastic shear Vn = Vp), cl. 8.4.1.1 (Av for I and channel sections); cl. 9.2.1 and 9.2.2 (moment capacity with low / high shear); Table 5 (γm0 = 1.10); Table 2 (section classification, named only).
  • For comparison only: EN 1993-1-1 and AISC 360. Not ranked; no values quoted.

Worked examples

Example 1 (plastic/compact, low shear)

Problem. A simply supported floor beam of effective span L = 5 m carries a factored UDL wu = 40 kN/m. A slab fully restrains the compression flange (laterally supported, cl. 8.2.1). The chosen I-section is plastic/compact in E250 with given design data Zp = 884 × 10³ mm³, Ze = 761 × 10³ mm³, h = 350 mm and tw = 8.1 mm. Take γm0 = 1.10. Check bending and shear under cl. 8.2.1.2 and cl. 8.4.1.

  1. Mu = wu L² / 8 = 40 × 5² / 8 = 125 kNm; Vu = wu L / 2 = 40 × 5 / 2 = 100 kN.
  2. βb = 1.0 (plastic/compact). Md0 = βb Zp fy / γm0 = 884 × 10³ × 250 / 1.10 / 10⁶ = 200.9 kNm.
  3. Simply-supported service cap (cl. 8.2.1.2): 1.2 Ze fy / γm0 = 1.2 × 761 × 10³ × 250 / 1.10 / 10⁶ = 207.5 kNm.
  4. Adopt Md = min(200.9, 207.5) = 200.9 kNm ≥ 125 kNm — bending OK.
  5. Av = h tw = 350 × 8.1 = 2 835 mm² (cl. 8.4.1.1, hot-rolled major axis).
  6. Vp = Av fyw / √3 = 2 835 × 250 / √3 = 409.2 kN; Vd = Vp / γm0 = 409.2 / 1.10 = 372.0 kN.
  7. 0.6 Vd = 0.6 × 372.0 = 223.2 kN. Vu = 100 kN ≤ 223.2 kN — low shear, so the Md of cl. 8.2.1.2 applies. Also Vu ≤ Vd — shear OK.
  8. Conclusion: the section is adequate for this laterally supported span.

Answer. Md = 200.9 kNm ≥ 125 kNm; V = 100 kN ≤ 0.6 Vd = 223.2 kN; OK

Example 2 (same section, high shear)

Problem. Keep the same plastic/compact E250 section (Zp = 884 × 10³ mm³, Ze = 761 × 10³ mm³, h = 350 mm, tw = 8.1 mm, Vd = 372.0 kN). The beam is still laterally supported but now spans L = 2.8 m under a factored UDL wu = 180 kN/m. Check whether cl. 8.2.1.2 still applies.

  1. Mu = 180 × 2.8² / 8 = 176.4 kNm; Vu = 180 × 2.8 / 2 = 252 kN.
  2. From Example 1, low-shear Md = 200.9 kNm ≥ 176.4 kNm, and Vd = 372.0 kN ≥ 252 kN, so a casual reading looks fine.
  3. But 0.6 Vd = 223.2 kN and Vu = 252 kN > 223.2 kN — the section is in high shear (cl. 8.2.1.3).
  4. Cl. 8.2.1.2 therefore does not apply. Md must be taken from the high-shear rules of cl. 8.2.1.3 and cl. 9.2.2 (reduced moment capacity under high shear). The reduced Md is lower than 200.9 kNm; the OCR of the exact coefficients on the box is not quoted here.
  5. Practical options: (1) apply the high-shear reduction and re-check Mu ≤ Md,reduced; (2) choose a thicker web or deeper section so that Vu ≤ 0.6 Vd and return to Example 1’s formula; (3) shorten the loaded length or redistribute load.
  6. Shear strength itself is still OK (252 < 372), but bending cannot use the full plastic Md until shear is brought down or the reduction is applied.

Answer. V = 252 kN > 0.6 Vd = 223.2 kN → high-shear path (cl. 8.2.1.3 / 9.2.2); do not use unreduced Md = 200.9 kNm

Example 3 (semi-compact βb effect)

Problem. Compare two laterally supported, simply supported designs in E250 with the same elastic modulus Ze = 761 × 10³ mm³ and γm0 = 1.10. Section A is plastic/compact with Zp = 884 × 10³ mm³ (Example 1). Section B is semi-compact with Zp = 920 × 10³ mm³ (given class). Find Md for each under low shear.

  1. Section A: βb = 1.0; Md0 = 884 × 10³ × 250 / 1.10 / 10⁶ = 200.9 kNm; cap 1.2 Ze fy / γm0 = 207.5 kNm; Md,A = 200.9 kNm.
  2. Section B: βb = Ze / Zp = 761 / 920 = 0.827; Md0 = 0.827 × 920 × 10³ × 250 / 1.10 / 10⁶ = 173.0 kNm.
  3. Check: βb Zp = Ze, so Md,B = Ze fy / γm0 = 761 × 10³ × 250 / 1.10 / 10⁶ = 173.0 kNm (same). The 1.2 Ze cap is larger (207.5 kNm) and does not govern.
  4. Same Ze, but the semi-compact section gives Md = 173.0 kNm against 200.9 kNm for the plastic section — a drop of about 28 kNm, because βb < 1 replaces Zp with Ze.
  5. Lesson: classification (Table 2) must be known before Md is computed; using Zp on a semi-compact section overstates strength.

Answer. Plastic Md = 200.9 kNm; semi-compact Md = 173.0 kNm (βb = 0.827) for the same Ze

Step-by-step procedure

  1. Confirm lateral support of the compression flange and nominal torsional restraint at supports (cl. 8.2.1); otherwise go to laterally unsupported design (cl. 8.2.2).
  2. Take effective span L from cl. 8.1.1; compute factored Mu and Vu for every load case.
  3. Classify the section (Table 2): plastic/compact → βb = 1.0; semi-compact → βb = Ze/Zp. Read Zp, Ze, h, tw (or d, tw) as design data.
  4. Shear: Av = h tw (hot-rolled I, major axis); Vp = Av fyw / √3; Vd = Vp / γm0; compare Vu with Vd and with 0.6 Vd (cl. 8.4.1, cl. 8.4.1.1).
  5. If Vu ≤ 0.6 Vd: Md = min(βb Zp fy / γm0, service cap with 1.2 Ze or 1.5 Ze) (cl. 8.2.1.2). If Vu > 0.6 Vd: use high-shear Md from cl. 8.2.1.3 / 9.2.2 or resize.
  6. Check holes (cl. 8.2.1.4) and shear-lag width limits (cl. 8.2.1.5) when flanges are wide or perforated.
  7. Check deflection under service loads (Section 5) and any concentrated-force / stiffener rules that apply.

Site notes

  • A cast-in-situ slab on shear connectors, or a composite metal deck welded to the top flange, is the usual way to claim continuous lateral restraint for floor beams; temporary bracing is still needed before the slab hardens.
  • At supports, web cleats or end plates that prevent the section from rotating about the beam axis provide the nominal torsional restraint assumed in cl. 8.2.1.
  • Do not call a beam laterally supported if only the tension flange is held — it is the compression flange that needs the restraint against LTB.
  • On site, holes for bolts near mid-span tension flanges should be reviewed against cl. 8.2.1.4 before the section modulus is taken as gross.
  • Paint and fire protection build-up do not change Av or Zp; use the bare steel dimensions from the mill certificate or design data sheet.
Common mistakes
  • Using the plastic Md formula on a beam that is not laterally supported — that needs the LTB check of cl. 8.2.2.
  • Taking βb = 1.0 for a semi-compact section; βb must be Ze/Zp.
  • Ignoring the 1.2 Ze fy / γm0 (or 1.5 Ze) service cap on simply supported (or cantilever) beams.
  • Comparing Vu with Vd only, and skipping the 0.6 Vd low-shear gate before using cl. 8.2.1.2.
  • Computing Av as the full section area instead of h tw (hot-rolled I, major-axis bending) per cl. 8.4.1.1.
  • Forgetting γm0 = 1.10 on both Md and Vd, or mixing fy of the flange with a different web grade without using fyw for shear.
  • Claiming continuous restraint from a slab that is not yet cast or not connected to the beam.
Quick check

Quick laterally supported check (E250, γm0 = 1.10): Md ≈ Zp / 4 400 kNm (Zp in mm³), then cap at 1.2 Ze / 4 400 for simply supported. Vd ≈ 0.1312 h tw kN (h, tw in mm; from Av fyw /(√3 γm0)). If V > 0.6 Vd, do not use the full plastic Md.

Summary

  • Laterally supported beams (cl. 8.2.1) develop Md from section yield, not from LTB.
  • For V ≤ 0.6 Vd: Md = βb Zp fy / γm0, capped by 1.2 Ze fy / γm0 (simply supported) or 1.5 Ze fy / γm0 (cantilever) (cl. 8.2.1.2).
  • βb = 1.0 plastic/compact; βb = Ze/Zp semi-compact.
  • Vp = Av fyw / √3 with Av = h tw for hot-rolled I major-axis bending; Vd = Vp / γm0 (cl. 8.4.1, cl. 8.4.1.1).
  • V > 0.6 Vd → high-shear reduction (cl. 8.2.1.3, cl. 9.2.2) or a stockier web.
  • γm0 = 1.10 (Table 5); Amend No.1: webs with d/tw > 67ε are the shear-buckling-susceptible case in cl. 8.2.1.1.

Practice questions

Tap a question to see the answer.

1What is βb for a plastic or compact section under cl. 8.2.1.2?

βb = 1.0.

2For Zp = 600 × 10³ mm³, Ze = 520 × 10³ mm³, fy = 250 N/mm², γm0 = 1.10, plastic, simply supported, find Md (low shear).

Md0 = 600 × 10³ × 250 / 1.10 / 10⁶ = 136.4 kNm; cap = 1.2 × 520 × 10³ × 250 / 1.10 / 10⁶ = 141.8 kNm; Md = 136.4 kNm.

3A hot-rolled I-section has h = 400 mm, tw = 8.9 mm, fyw = 250 N/mm², γm0 = 1.10. Find Av, Vp, Vd and 0.6 Vd.

Av = 400 × 8.9 = 3 560 mm²; Vp = 3 560 × 250 / √3 = 513.8 kN; Vd = 513.8 / 1.10 = 467.1 kN; 0.6 Vd = 280.3 kN.

4When must a laterally supported beam leave the simple Md formula of cl. 8.2.1.2?

When the factored shear V exceeds 0.6 Vd (high shear, cl. 8.2.1.3 / 9.2.1–9.2.2), or when the beam is not adequately laterally supported (then use cl. 8.2.2).

5A semi-compact section has Ze = 450 × 10³ mm³ and Zp = 600 × 10³ mm³, fy = 250, γm0 = 1.10. Find βb and Md (low shear).

βb = 450/600 = 0.75; Md = 0.75 × 600 × 10³ × 250 / 1.10 / 10⁶ = 102.3 kNm (= Ze fy / γm0).

6What effective span does cl. 8.1.1 use for ordinary centre-bearing supports?

The distance between the centres of the supports (or between assumed reaction lines if the reaction is taken as eccentric).

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • N. Subramanian, Design of Steel Structures, Oxford University Press, New Delhi, 1st edition, 2008.