5.4 Staircases
After this lesson you should be able to:
- Recognise the common stair types (straight, dog-legged, open-well, cantilevered steps) and how each one carries its load: along the flight or across it.
- Find the effective span, loads per plan area and design moment of a stair flight with IS 456:2000 cl. 33.1 to cl. 33.3, and design the waist slab as a one-way slab.
- Apply the open-well and wall-embedment provisions of cl. 33.2 and detail the main, distribution and landing bars correctly.
Theory
A staircase is a series of steps that lets people move between floors, and in a reinforced concrete building it is usually an inclined slab, called the waist, with the steps formed on top. The rise R is the vertical height of one step and the going (tread) T is its horizontal depth. Comfortable stairs keep R and T in proportion; a common rule of thumb keeps 2R + T close to 600 mm, so a 160 mm rise goes with a tread of about 250 to 280 mm. The structural question is how the flight carries its load to the supports.
Most building stairs span longitudinally, along the slope, between landings or beams at the top and bottom. The flight is then designed exactly like a one-way slab (lesson 5.1) whose span is measured horizontally. Other stairs span transversely: each step can be cantilevered from a wall or a central beam, or the flight can span between two inclined stringer beams. Dog-legged stairs (two flights in opposite directions with a half landing) and open-well stairs (flights around an open well) are the usual layouts in Indian buildings.
IS 456:2000 cl. 33.1 gives the effective span of stairs without stringer beams as a horizontal distance: centre to centre of beams at the top and bottom risers; or, where the flight spans onto landings that span parallel with the risers, the going plus at each end half the landing width or one metre, whichever is smaller; or, where the landing spans in the same direction as the flight, the whole length of flight and landings between supporting beams or walls. Cl. 33.3 takes the depth of section as the minimum thickness perpendicular to the soffit, which is the waist.
Loads on a stair act on its plan area. The waist is inclined, so its self-weight per square metre of plan is larger than γ times its thickness, by the factor √(R² + T²)/T; the triangular steps add γ R/2 on average; finishes and the imposed load are added per plan area. Cl. 33.2 lets the load on areas common to two crossing spans in open-well stairs be shared half to each, and allows a 150 mm strip to be deducted from the loaded width, with a 75 mm wider effective breadth, where a flight is built into a wall for at least 110 mm.
Derivation
- Waist self-weight per plan area: a strip of plan length T contains an inclined waist of length √(R² + T²) and thickness t, so the weight per plan area is γ t √(R² + T²)/T.
- Steps: each step is a triangle of area R T/2 over plan length T, so its average weight per plan area is γ R/2.
- Total load per plan area: w = γ t √(R² + T²)/T + γ R/2 + finish + imposed load; wu = 1.5 w.
- Effective span (cl. 33.1 (b)) for a flight spanning onto landings that span parallel to the risers: l = G + min(B1/2, 1 m) + min(B2/2, 1 m), with G the going of the flight and B1, B2 the landing widths.
- Design moment and shear for a simply supported flight: Mu = wu l²/8 and Vu = wu l/2 per metre width; the horizontal projection is used because the loads are vertical and per plan area, so an inclined member of span l under vertical load w per horizontal metre has the same moment as a horizontal beam.
- Section: cl. 33.3 takes the depth as the minimum thickness perpendicular to the soffit, so d = waist − cover − φ/2, and Ast follows from the Chapter 2 formula with b = 1 000 mm; minimum steel, spacing and deflection are checked as for one-way slabs (lesson 5.1).
Waist load per plan area: γ t √(R² + T²)/T (kN/m²; γ in kN/m³, t in m)Steps: γ R/2 per plan area (kN/m²)Effective span (cl. 33.1 (b)): l = G + min(B1/2, 1 m) + min(B2/2, 1 m) (m)Moment and shear per metre width: Mu = wu l²/8, Vu = wu l/2 (kN m, kN)Depth: d = waist − cover − φ/2, measured perpendicular to the soffit (mm)Wall-embedded flight (cl. 33.2): loaded width b − 150 mm, effective breadth b + 75 mm (mm)
- The flight spans longitudinally as a one-way slab without stringer beams; loads are uniform per plan area.
- Supports are simple (beams or landings) unless the landing and flight act as one continuous slab (cl. 33.1 (c)).
- Partial safety factor 1.5 on loads; the waist is under-reinforced and the minimum steel and spacing rules of slabs apply.
- The flight is designed for vertical loads; the small axial thrust along the incline is ignored, as is usual for building stairs.
- Limits: transversely spanning steps, cantilever and spiral stairs, stairs with stringer beams, folded-plate (sawtooth) stairs and the seismic interaction of stairs with the building frame need separate treatment.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- IS 456:2000 cl. 33.1 (a) (effective span centre to centre of beams at the top and bottom risers), cl. 33.1 (b) (going plus at each end half the landing width or one metre, whichever is smaller, for landings spanning parallel with the risers), cl. 33.1 (c) (landing spanning in the same direction as the stairs: flight and landing act as one slab, span centre to centre of the supporting beams or walls), cl. 33.2 (open wells: load on common areas taken one-half in each direction; flights embedded at least 110 mm into walls: 150 mm strip deducted from the loaded area and effective breadth increased by 75 mm), cl. 33.3 (depth = minimum thickness perpendicular to the soffit).
- IS 456:2000 cl. 26.5.2.1 and cl. 26.5.2.2 (minimum steel and bar diameter, as in lesson 5.1), cl. 26.3.3 (b) (bar spacing, as in lesson 5.1), cl. 23.2.1 (deflection, as in lesson 4.1), cl. 26.2.1 (development length, as in lesson 3.2); IS 1786 deformed bars; the imposed load is taken from the loading code for the building use.
- Indian, European and American practice are listed side by side and not ranked: the European concrete code (EN 1992-1-1) designs stair flights as slabs with its own span definitions, minimum reinforcement and deflection rules; the American code (ACI 318) designs them as one-way slabs with its own thickness and reinforcement provisions. Neither sets values that are reproduced here.
Worked examples
Problem. A dog-legged stair has flights of 10 treads, rise 160 mm and tread 250 mm, so the going is 2.5 m. Each flight spans onto landings 1.2 m wide that span parallel with the risers. M20 concrete, Fe 415 bars, 20 mm clear cover, finish 1.0 kN/m², imposed load 3.0 kN/m² (unit weight 25 kN/m³). Design the waist slab.
- Effective span (cl. 33.1 (b)): 2.5 + min(0.6, 1) + min(0.6, 1) = 3.7 m. √(160² + 250²) = 296.8 mm, factor 296.8/250 = 1.187.
- Try a 150 mm waist: w = 0.15 × 25 × 1.187 + 25 × 0.16/2 + 1.0 + 3.0 = 4.45 + 2.0 + 4.0 = 10.45 kN/m², wu = 15.68 kN/m², Mu = 26.8 kN m/m; d = 124 mm, Ast = 676 mm²/m, 12 mm at 160 mm. Deflection: fs = 230 N/mm², pt = 0.57 per cent, factor about 1.23, allowable 24.6 < 3 700/124 = 29.8: fails.
- Use a 170 mm waist: w = 0.17 × 25 × 1.187 + 2.0 + 4.0 = 5.05 + 6.0 = 11.05 kN/m², wu = 16.57 kN/m²; Mu = 16.57 × 3.7²/8 = 28.35 kN m/m; d = 170 − 20 − 6 = 144 mm (cl. 33.3, perpendicular to the soffit).
- Ast = 597 mm²/m → 12 mm at 180 mm (628 mm²/m). Deflection: fs = 0.58 × 415 × 597/628 = 228.7 N/mm², pt = 0.44 per cent, factor about 1.36, allowable 27.2 ≥ 3 700/144 = 25.7: passes.
- Distribution: 0.12 per cent × 1 000 × 170 = 204 mm²/m → 8 mm at 240 mm (209 mm²/m). Shear: Vu = 16.57 × 3.7/2 = 30.7 kN/m, τv = 0.21 N/mm², far below τc: no shear steel. Main bars continue into the landings with at least the development length (47 × 12 = 564 mm).
Answer. 170 mm waist with 12 mm bars at 180 mm and 8 mm distribution bars at 240 mm
Problem. Find the effective span of a flight with going 3.0 m in three cases: (a) beams at the top and bottom risers 3.2 m apart centre to centre; (b) landings 1.5 m and 2.5 m wide spanning parallel with the risers; (c) landings 1.2 m wide at each end spanning in the same direction as the flight, carried by walls whose centre-lines are 5.4 m apart.
- (a) cl. 33.1 (a): centre to centre of beams, 3.2 m.
- (b) cl. 33.1 (b): 3.0 + min(1.5/2, 1) + min(2.5/2, 1) = 3.0 + 0.75 + 1.0 = 4.75 m.
- (c) cl. 33.1 (c): flight and landings act as one slab between the walls: 5.4 m, measured horizontally.
- Moments grow with the square of the span, so case (c) gives (5.4/3.2)² = 2.85 times the moment of case (a) for the same load.
Answer. 3.2 m, 4.75 m and 5.4 m
Problem. The flight of Example 1 (170 mm waist, wu = 16.57 kN/m², span 3.7 m) is 1.1 m wide and is built into a brick wall along one side for 115 mm. How does cl. 33.2 change the design moment per metre? What happens to the load where two flights of an open-well stair cross at a landing?
- Embedment 115 mm ≥ 110 mm, so a 150 mm strip may be deducted from the loaded area: loaded width 1.1 − 0.15 = 0.95 m.
- The effective breadth for design is increased by 75 mm: 1.1 + 0.075 = 1.175 m.
- Moment for the flight: 16.57 × 0.95 × 3.7²/8 = 26.9 kN m, or 26.9/1.175 = 22.9 kN m per metre of effective breadth, compared with 28.35 kN m/m without the concession, about 19 per cent less.
- In an open-well stair the load on a landing area common to two crossing spans may be taken one-half in each direction (cl. 33.2), so each span carries half of that square, not all of it.
Answer. About 22.9 kN m/m instead of 28.35 kN m/m; shared landing areas carry half their load in each direction
Step-by-step procedure
- Fix the stair layout: floor height, number of risers, rise and tread (2R + T near 600 mm), flight widths and landing sizes.
- Decide how each flight spans (longitudinally between landings or beams, transversely, or with landings in the same direction) and find the effective span by cl. 33.1.
- Choose a trial waist from deflection (span/effective depth about 20 to 25 for simply supported flights with Fe 415), and compute loads per plan area including the √(R² + T²)/T factor and steps.
- Find Mu and Vu per metre (apply cl. 33.2 for open wells and wall embedment), compute Ast with d measured perpendicular to the soffit (cl. 33.3) and check spacing, minimum steel, deflection and shear.
- Provide distribution steel, continue main bars into landings with full development length, and detail the bars at the kinks so that they do not straighten under tension.
- Design landings and landing beams for the reactions of the flights.
Site notes
- At the re-entrant kink between flight and landing, tension bars must not be bent round the inside corner, because they straighten and spall the cover; cross the bars and anchor each one past the kink.
- Check that the waist thickness is measured perpendicular to the soffit on the shuttering, not vertically.
- Form steps to the same rise throughout; a different first or last riser is a common cause of trips and falls.
- Provide nosing and non-slip finishes as specified; cast the steps with the waist where possible to avoid weak cold joints.
- Keep props under flights until the landings and landing beams have gained strength.
- Calculating self-weight from the waist thickness alone, forgetting the √(R² + T²)/T factor and the steps.
- Measuring the span along the slope instead of horizontally.
- Taking the full landing width in the effective span when cl. 33.1 (b) allows only half of it, and not more than 1 m, at each end.
- Bending the main bars round the inside of the kink between flight and landing.
- Using the vertical thickness instead of the waist perpendicular to the soffit as the depth.
For residential and office stairs with Fe 415 bars, a waist of about span/20 to span/22 (overall) usually satisfies deflection, and the inclined self-weight factor √(R² + T²)/T is about 1.15 to 1.2 for comfortable stairs. Stair steel commonly lands at 10 or 12 mm bars at 150 to 200 mm.
Summary
- Building stairs usually span longitudinally as inclined one-way slabs; some span transversely as cantilevered or supported steps.
- Cl. 33.1 gives the effective span horizontally: between beams, going plus half landing (up to 1 m) at each end, or flight plus landings as one slab.
- Loads are per plan area: the waist weight is multiplied by √(R² + T²)/T, steps add γ R/2, plus finishes and imposed load.
- Cl. 33.2 shares common open-well areas half each way and allows a 150 mm strip deduction with 75 mm extra breadth for flights built at least 110 mm into walls; cl. 33.3 measures depth perpendicular to the soffit.
- Design, deflection and detailing follow one-way slabs; anchor bars past the kinks.
Practice questions
Tap a question to see the answer.
1Find the inclined self-weight factor for R = 150 mm and T = 300 mm.
√(150² + 300²)/300 = 1.118.
2A flight has going 2.7 m and landings 2.4 m wide at both ends spanning parallel with the risers. Find its effective span.
2.7 + 1.0 + 1.0 = 4.7 m (half the landing, 1.2 m, exceeds 1 m).
3Find the average weight of the steps per plan area for R = 150 mm (γ = 25 kN/m³).
25 × 0.15/2 = 1.875 kN/m².
4How is the depth of a stair section measured?
As the minimum thickness perpendicular to the soffit (cl. 33.3).
5Check 2R + T for R = 175 mm and T = 250 mm.
2 × 175 + 250 = 600 mm, close to the comfortable value.
6A landing area is common to two crossing spans in an open-well stair. What load does each span take from it?
One-half of the load on that area (cl. 33.2).
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- S. U. Pillai, D. Menon, Reinforced Concrete Design, Tata McGraw Hill (now McGraw Hill Education (India)), 3rd edition, 2009.
- P. C. Varghese, Limit State Design of Reinforced Concrete, Prentice Hall of India (PHI Learning), 2nd edition, 2008.
- J. K. Wight, J. G. MacGregor, Reinforced Concrete: Mechanics and Design, Pearson, 6th edition, 2012.
- R. Park, T. Paulay, Reinforced Concrete Structures, John Wiley and Sons, 1975.