Indiacon CivilSubscribe

Textbook › Reinforced Concrete Design › Chapter 3 › Lesson 3.4

3.4 Detailing rules for beams

Reinforced Concrete Design Chapter 3: Shear, bond and torsion Under review — not yet three-checked Author: Indiacon

Learning objectives

After this lesson you should be able to:

  • Curtail tension bars correctly: find the theoretical cut-off point, extend bars by the greater of d and 12 φ (cl. 26.2.3.1) and satisfy one of the conditions of cl. 26.2.3.2 for stopping bars in a tension zone.
  • Detail positive steel into supports and negative steel beyond points of inflection by cl. 26.2.3.3 and 26.2.3.4, including hogging regions of continuous T-beams.
  • Apply the bar-spacing, side-face, cover, stirrup and steel-limit rules of IS 456 to arrange bars in a beam that can be built and compacted properly.

Theory

Design gives the steel areas; detailing makes them work. A beam with the right amount of steel can still fail if bars stop too early, are not anchored, are too close together for concrete to flow between them, or lack cover. Most of the rules in this lesson follow from the ideas of lessons 3.1 and 3.2: every bar must develop its force on each side of a critical section, and shear cracks change where bar forces act.

Bars are not needed at full area along the whole span, because the bending moment falls towards supports and points of inflection. The theoretical cut-off point of a bar is where the moment of resistance of the continuing bars equals the design moment (Note to cl. 26.2.3.1). A diagonal crack, however, shifts the tension force in a bar towards the support (the tension at a section depends on the moment at the top of the crack, not at its foot), so cl. 26.2.3.1 asks for bars to extend beyond the theoretical point by the greater of d and 12 φ. Stopping bars in a tension zone also creates a stress concentration that can start a diagonal crack, so cl. 26.2.3.2 permits it only if the shear there is low enough, extra stirrups are provided, or the continuing bars have double the required area.

Detailing a continuous beamPIPIbeyond PIinto support: one third of bottom steel, Ld/3cut-off + d or 12φIndiacon original, not to scale
Figure 3.4: Detailing a two-span continuous beam: part of the bottom steel is curtailed beyond its theoretical cut-off by d or 12 φ while at least one-third runs into the supports, top bars over the middle support extend beyond the points of inflection (PI), and stirrups are closer near the supports. Indiacon original, not to scale.

Supports and points of inflection need their own rules. At least one-third of the positive moment steel in simple members, and one-quarter in continuous members, must run into the support for at least Ld/3 (cl. 26.2.3.3 (a)), and the bar size must pass the M1/V + L0 check of lesson 3.2. Over interior supports, at least one-third of the negative moment steel must extend beyond the point of inflection by the greatest of d, 12 φ and one-sixteenth of the clear span (cl. 26.2.3.4), because the point of inflection moves when the loading pattern changes. In continuous T-beams the support section is a hogging section with the flange in tension: part of the main tension steel is spread over the effective flange width or one-tenth of the span, whichever is smaller (cl. 26.5.1.8), and the slab bars there help to carry the tension.

Spacing and cover rules let the concrete do its job. The clear horizontal distance between bars must usually be at least the bar diameter (the larger diameter if unequal) and 5 mm more than the nominal maximum size of coarse aggregate (cl. 26.3.2), so that concrete can flow and be vibrated around them. Nominal cover is fixed by exposure (cl. 26.4.2 with Table 16: 20, 30, 45, 50 and 75 mm for mild, moderate, severe, very severe and extreme). Webs deeper than 750 mm need side-face bars of at least 0.1 per cent of the web area on the two faces at not more than 300 mm or the web thickness (cl. 26.5.1.3) to control cracking. Stirrups enclose the outermost bars (cl. 26.5.1.4), and the steel limits of cl. 26.5.1.1 and 26.5.1.2 (minimum 0.85 b d/fy, maximum 0.04 b D) still apply.

Derivation

  1. Theoretical cut-off for a simply supported beam under uniform load w: the moment at x from the support is M(x) = w x (L − x)/2. Setting M(x) = Mr, the resistance of the continuing bars, gives x = [L − √(L² − 8 Mr/w)]/2.
  2. Actual cut-off: move the bar end towards the support by max(d, 12 φ) (cl. 26.2.3.1), because a diagonal crack starting there carries the bar force associated with a section about d closer to midspan.
  3. Condition (a) of cl. 26.2.3.2: at the actual cut-off, the shear must not exceed two-thirds of the shear capacity (concrete with the continuing bars plus the stirrups provided). Condition (b): extra stirrups of area at least 0.4 b s/fy over 0.75 d from the cut-off, at a spacing not more than d/(8 βb), where βb is the ratio of bars cut off to bars at the section. Condition (c), for bars up to 36 mm: the continuing bars provide double the area required for flexure there and the shear is at most three-quarters of that permitted.
  4. Point of inflection of a fixed-ended span under uniform load: M(x) = w (6 l x − 6 x² − l²)/12 is zero at x = l (1/2 − √3/6) = 0.211 l from each support face.
  5. Negative steel extension beyond the point of inflection: at least one-third of the support steel continues for the greatest of d, 12 φ and ln/16 (cl. 26.2.3.4).
  6. Clear spacing of n bars of diameter φ across a web b with cover c and stirrup diameter φs: s = (b − 2c − 2 φs − n φ)/(n − 1), compared with the greater of φ and (aggregate size + 5 mm) (cl. 26.3.2).
Formulas, symbols and SI units
  • Theoretical cut-off (UDL, simple span): x = [L − √(L² − 8 Mr/w)]/2 (m; L in m, Mr in kN m, w in kN/m)
  • Extension beyond theoretical cut-off: greater of d and 12 φ (mm), cl. 26.2.3.1
  • Negative steel beyond point of inflection: at least one-third of the bars for the greatest of d, 12 φ and ln/16 (mm), cl. 26.2.3.4
  • Positive steel into supports: at least one-third (simple) or one-quarter (continuous) of the bars for Ld/3 (mm), cl. 26.2.3.3 (a)
  • Clear spacing: s = (b − 2c − 2 φs − n φ)/(n − 1) ≥ greater of φ and (aggregate size + 5 mm) (mm), cl. 26.3.2
  • Side-face steel when web depth > 750 mm: As ≥ 0.001 × web area, split equally on two faces, spacing ≤ 300 mm and ≤ web thickness (mm²), cl. 26.5.1.3
Assumptions and limits
  • The design moment and shear envelopes used for curtailment cover all load patterns, including alternate-span loading in continuous beams.
  • Bars are deformed bars to IS 1786 with development lengths from lesson 3.2; bundled bars terminate at points at least 40 φ apart except at supports (cl. 26.2.3.5).
  • Cover values are the nominal covers of cl. 26.4.2 for durability; fire resistance may require more.
  • The aggregate size used in the spacing check is the nominal maximum size actually specified for the member; the code allows smaller aggregate locally around congested bars (Note to cl. 26.3.2).
  • Limits: members where steel stress is not proportional to moment, such as sloped or stepped footings, brackets and deep beams, need special anchorage (cl. 26.2.4); earthquake-resistant beams follow additional ductile detailing rules (RCC Chapter 8).

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • IS 456:2000 cl. 26.2.3.1 (extend bars beyond the theoretical cut-off by the greater of d and 12 φ, except at simple supports and cantilever ends), cl. 26.2.3.2 (a) to (c) (conditions for stopping bars in a tension zone: shear at most two-thirds of capacity; excess stirrups 0.4 b s/fy over 0.75 d at spacing not more than d/(8 βb); for bars up to 36 mm, double area and shear at most three-quarters), cl. 26.2.3.3 (positive steel into supports: one-third or one-quarter for Ld/3; Ld ≤ M1/V + L0), cl. 26.2.3.4 (one-third of negative steel beyond the point of inflection for the greatest of d, 12 φ and one-sixteenth of the clear span), cl. 26.2.3.5 (bundled bars stopped at least 40 φ apart).
  • IS 456:2000 cl. 26.3.2 (minimum clear distance: bar diameter, larger diameter if unequal, and 5 mm more than the nominal maximum aggregate size), cl. 26.4.2 with Table 16 (nominal cover 20, 30, 45, 50 and 75 mm for mild, moderate, severe, very severe and extreme exposure), cl. 26.5.1.1 and 26.5.1.2 (0.85 b d/fy minimum, 0.04 b D maximum), cl. 26.5.1.3 (side-face steel 0.1 per cent of web area for webs deeper than 750 mm, spacing not more than 300 mm or the web thickness), cl. 26.5.1.4 to 26.5.1.6 (stirrups round the outermost bars, spacing and minimum, lesson 3.1), cl. 26.5.1.8 (tension flanges: part of the main steel over the effective flange width or one-tenth of the span, whichever is smaller).
  • Indian, European and American practice are listed side by side and not ranked: the European concrete code (EN 1992-1-1) uses a shift rule for the tension force envelope and its own anchorage, lap, spacing and cover rules; the American code (ACI 318) specifies bar extensions beyond cut-off points and points of inflection, minimum embedment into supports and its own spacing and cover limits. The numbers differ and are not reproduced here.

Worked examples

Example 1 (design style: curtailing bottom bars)

Problem. A simply supported beam of 6.0 m effective span on 300 mm wide supports carries a factored load of 40 kN/m. It is 300 mm wide with d = 500 mm, M20 concrete and Fe 415 steel, with four 20 mm bottom bars and two-legged 8 mm stirrups. Two bars are to be stopped short of the supports. Find where, and check cl. 26.2.3.2 (a) and the anchorage of the two continuing bars.

  1. Mu = 40 × 6.0²/8 = 180 kN m. Four bars (1 257 mm²): xu = 210.1 mm < 240 mm, Mr = 186.8 kN m ≥ 180. Two bars (628 mm²): xu = 105.0 mm, Mr = 103.4 kN m.
  2. Theoretical cut-off: x = [6.0 − √(36 − 8 × 103.4/40)]/2 = 1.043 m from the support centre.
  3. Extend by the greater of d = 500 mm and 12 φ = 240 mm: actual cut-off 1.043 − 0.500 = 0.543 m from the support centre. Shear there: Vu = 40 × (3.0 − 0.543) = 98.3 kN.
  4. Capacity at the cut-off with the two continuing bars (pt = 0.42 per cent, τc = 0.441 N/mm², Vc = 66.2 kN): with minimum stirrups at 300 mm, Vus = 60.5 kN and two-thirds of 126.7 kN is 84.5 kN < 98.3 kN, so condition (a) fails. With stirrups at 200 mm, Vus = 90.7 kN and two-thirds of 156.9 kN is 104.6 kN ≥ 98.3 kN, so provide 2L-8 at 200 mm over the first 1.2 m.
  5. Continuing bars into each support for Ld/3 = 940/3 = 313 mm; with 260 mm of straight length available beyond the face, turn the bars up with a 90-degree bend (8 φ = 160 mm). Check cl. 26.2.3.3 (c): 1.3 × 103.4 × 10⁶/120 000 + (110 + 160) = 1 390 mm ≥ Ld = 940 mm.

Answer. Stop two bars 0.54 m from each support centre (theoretical 1.04 m), with 2L-8 at 200 mm over 1.2 m; continuing bars bent up at the supports

Example 2 (exam style: top bars beyond the point of inflection)

Problem. An interior span of a continuous beam behaves as fixed-ended under its governing uniform load. Its clear span is 6.6 m, d = 550 mm and the top bars over the supports are 20 mm. Find the point of inflection and how far at least one-third of the top bars must run from the support face.

  1. Point of inflection: 0.211 × 6.6 = 1.395 m from each support face (x = l (1/2 − √3/6)).
  2. Extension beyond the point of inflection: greatest of d = 550 mm, 12 φ = 240 mm and ln/16 = 6 600/16 = 412.5 mm, so 550 mm.
  3. At least one-third of the top bars run to 1.395 + 0.550 = 1.945 m from the support face; the remaining top bars may stop where they are no longer needed plus d or 12 φ, checking cl. 26.2.3.2.
  4. Over the support the top bars must also develop their stress on both sides of the face: Ld = 47 × 20 = 940 mm into the support or the adjoining span.

Answer. Point of inflection 1.40 m from the face; one-third of the top bars to at least 1.95 m from the face

Example 3 (site style: arranging bars in a deep T-beam)

Problem. A T-beam has a 300 mm web, overall depth 900 mm and a 120 mm slab, in severe exposure, with four 25 mm bottom bars in one layer, 8 mm stirrups and 20 mm aggregate. Check the clear spacing of the bottom bars with the Table 16 cover and decide the side-face steel.

  1. Nominal cover for severe exposure: 45 mm to all reinforcement including stirrups (cl. 26.4.2, Table 16).
  2. Clear spacing: (300 − 2 × 45 − 2 × 8 − 4 × 25)/3 = 31.3 mm; required: the greater of 25 mm (bar size) and 20 + 5 = 25 mm. 31.3 mm ≥ 25 mm: one layer works.
  3. Web depth = 900 − 120 = 780 mm > 750 mm, so side-face steel is required: 0.1 per cent × 300 × 780 = 234 mm², 117 mm² per face.
  4. Spacing not more than 300 mm and not more than the web thickness (300 mm): provide two 10 mm bars on each face (157 mm² per face) at about 260 mm vertical spacing.
  5. Over interior supports, spread part of the hogging steel into the flange within the effective width or one-tenth of the span, whichever is smaller (cl. 26.5.1.8).

Answer. Clear spacing 31.3 mm ≥ 25 mm (one layer); side-face steel 2-10 on each face at about 260 mm

Step-by-step procedure

  1. Draw the moment and shear envelopes for all load patterns; mark points of inflection and maximum moments.
  2. Choose bar sizes and numbers for each critical section and check clear spacing and cover (cl. 26.3.2, 26.4.2).
  3. Find theoretical cut-off points from the resistance of the continuing bars; extend by the greater of d and 12 φ and check one condition of cl. 26.2.3.2.
  4. Run at least one-third (simple) or one-quarter (continuous) of the bottom bars into supports for Ld/3 and check M1/V + L0; extend at least one-third of the top bars beyond the point of inflection by the greatest of d, 12 φ and ln/16.
  5. Add side-face bars for webs deeper than 750 mm, corner bars for every stirrup, and compression-bar ties; check minimum and maximum steel.
  6. Draw the bar bending schedule with lengths, bends, laps and stirrup zones, and check it against the rules before issue.

Site notes

  • Cut-off points and laps are the details most often changed on site; any shortening of bars needs the designer's approval.
  • Check the clear spacing of bars at congested joints before concreting; where bars from beams and columns cross, prepare the joint detail in advance.
  • Use cover blocks of the specified size under bottom bars and chairs under top bars; top bars pressed down by foot traffic lose effective depth over supports.
  • Side-face bars in deep beams are often omitted because they are not 'main steel'; without them wide cracks appear on the faces.
  • Keep the extension of top bars beyond the point of inflection even when the slab is cast later; the point of inflection moves with the loading pattern.
Common mistakes
  • Stopping bars at the theoretical cut-off point without the extension of d or 12 φ.
  • Stopping bars in a tension zone without checking any condition of cl. 26.2.3.2.
  • Running fewer than one-third of the bottom bars into a simple support, or not anchoring them for Ld/3.
  • Using the effective span instead of the clear span for ln/16, or forgetting that the point of inflection moves with alternate-span loading.
  • Fixing bars closer than the bar diameter or aggregate size plus 5 mm, which leaves honeycombing under the bars.
Quick check

In a simply supported beam under uniform load, half the bars can theoretically stop where M falls to about half of Mu, roughly 0.15 L from each support; after the d or 12 φ extension the saving is often small, so many designers run all bottom bars to the supports in short spans. Points of inflection of fixed-ended spans under uniform load lie at 0.21 of the clear span from each face. One layer of four 25 mm bars at the minimum 25 mm clear spacing needs a web of about 250 mm with 30 mm cover and 8 mm stirrups, and about 280 mm with 45 mm cover.

Summary

  • Bars must extend the greater of d and 12 φ beyond their theoretical cut-off points, and stopping bars in a tension zone needs one of the conditions of cl. 26.2.3.2.
  • At least one-third (simple) or one-quarter (continuous) of the positive steel runs into the support for Ld/3, and bar size is limited by Ld ≤ M1/V + L0 (1.3 M1/V + L0 when confined).
  • At least one-third of the negative steel continues beyond the point of inflection for the greatest of d, 12 φ and ln/16; in T-beams part of the hogging steel is spread into the flange.
  • Clear spacing is at least the bar diameter and aggregate size plus 5 mm; nominal cover follows exposure (20 to 75 mm by Table 16); webs deeper than 750 mm get side-face steel of 0.1 per cent of the web area.
  • Stirrups enclose the outermost bars, and the steel limits 0.85 b d/fy and 0.04 b D still apply.

Practice questions

Tap a question to see the answer.

1How far beyond its theoretical cut-off point must a 16 mm bar extend in a beam with d = 450 mm?

The greater of d = 450 mm and 12 × 16 = 192 mm: 450 mm.

2Top bars of 20 mm over a support in a beam with d = 500 mm and clear span 7.2 m: how far must one-third of them extend beyond the point of inflection?

Greatest of 500 mm, 240 mm and 7 200/16 = 450 mm: 500 mm.

3Find the side-face steel for a web 300 mm wide and 800 mm deep.

0.1 per cent × 300 × 800 = 240 mm², 120 mm² on each face at not more than 300 mm spacing.

4What is the minimum clear distance between 20 mm bars with 20 mm nominal maximum aggregate?

The greater of 20 mm and 20 + 5 = 25 mm: 25 mm.

5Bars cut off at a section are half of the bars there (βb = 0.5) in a beam with d = 480 mm. If condition (b) of cl. 26.2.3.2 is used, what is the largest spacing of the extra stirrups?

d/(8 βb) = 480/(8 × 0.5) = 120 mm, over a length 0.75 d = 360 mm from the cut-off.

6Why must bars extend beyond the theoretical cut-off point at all?

A diagonal crack shifts the tension force in the bars towards the support, and a bar needs embedment to develop its stress; the extension of d or 12 φ covers both effects.

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • S. U. Pillai, D. Menon, Reinforced Concrete Design, Tata McGraw Hill (now McGraw Hill Education (India)), 3rd edition, 2009.
  • P. C. Varghese, Limit State Design of Reinforced Concrete, Prentice Hall of India (PHI Learning), 2nd edition, 2008.
  • J. K. Wight, J. G. MacGregor, Reinforced Concrete: Mechanics and Design, Pearson, 6th edition, 2012.
  • R. Park, T. Paulay, Reinforced Concrete Structures, John Wiley and Sons, 1975.
Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.

Sent privately to the Indiacon editor; not published.