Indiacon CivilSubscribe

Textbook › Reinforced Concrete Design › Chapter 2 › Lesson 2.4

2.4 Flanged beams

Reinforced Concrete Design Chapter 2: Limit state of collapse: flexure Under review — not yet three-checked Author: Indiacon

Learning objectives

After this lesson you should be able to:

  • Explain why a beam cast with a slab acts as a T-beam or L-beam in sagging, and find the effective flange width by the rules of IS 456:2000 cl. 23.1.2.
  • Find the moment of resistance of a flanged section with the neutral axis in the flange and in the web, using Annex G, G-2 with the Df/d and Df/xu conditions.
  • Design or check the tension steel of a flanged beam and apply the requirements of cl. 23.1.1 for the slab to act as a flange.

Theory

Most floor beams are cast together with the slab. Under a sagging moment the top of the beam is in compression, and the slab on either side shares that compression, so the beam behaves as a T-section (an internal beam) or an L-section (an edge beam). The large flange gives a big compression area close to the top, so the neutral axis is usually shallow and the lever arm long: a flanged beam needs less steel than a rectangular beam of the web width. Under hogging moment near supports the flange is in tension and gives no help in compression, so those sections are designed as rectangular sections of width bw.

The compressive stress in a wide flange is not uniform across its width: it is highest over the web and falls with distance from it, an effect called shear lag. Design replaces the real flange by an effective width bf carrying uniform stress. IS 456:2000 cl. 23.1.2 gives, in the absence of a more accurate determination, bf = l0/6 + bw + 6 Df for T-beams and bf = l0/12 + bw + 3 Df for L-beams, but not more than the web width plus half the sum of the clear distances to the adjacent beams (or half the clear distance on the one side for an L-beam). Here l0 is the distance between points of zero moment, which may be taken as 0.7 times the effective span for continuous beams and frames. For isolated beams, bf = l0/(l0/b + 4) + bw for a T-beam and 0.5 l0/(l0/b + 4) + bw for an L-beam, where b is the actual flange width, and bf may not exceed b.

Flanged (T) beam: neutral axis in flange or webbfbwDfdNA in flangeNA in web0.45 fckover yfweb blockTstress (web case)Indiacon original, not to scale
Figure 2.4: Flanged beam: the effective flange width bf, flange thickness Df, web width bw and effective depth d, with the neutral axis either within the flange (rectangular analysis with width bf) or in the web, where the flange outstand carries a uniform 0.45 fck over the depth yf and the web carries the usual stress block. Indiacon original, not to scale.

Once bf is known the analysis depends on where the neutral axis falls. If xu ≤ Df the compression zone is a rectangle of width bf, and the section is analysed exactly as a rectangular beam of width bf (Annex G, G-2.1); the concrete below the flange is in tension and is ignored anyway. If xu > Df the compression zone is T-shaped: the web carries a normal stress block 0.36 fck bw xu, and the outstanding flange (bf − bw) carries a compression that the code takes as a uniform 0.45 fck over a depth that depends on how thick the flange is compared with the stress block.

Annex G, G-2.2 gives the limiting moment when Df/d does not exceed 0.2, taking the whole flange depth at 0.45 fck. When Df/d exceeds 0.2 (G-2.2.1) the flange thickness is replaced by yf = 0.15 xu + 0.65 Df, not more than Df, which approximates the part of the flange that lies in the uniform-stress zone of the parabolic-rectangular block. For a section with xu between Df and xu,max, G-2.3 uses the same equations with xu in place of xu,max, choosing the G-2.2 form when Df/xu does not exceed 0.43 and the yf form when it does; 0.43 is 3/7, the fraction of the neutral-axis depth over which the concrete stress is uniform. Clause 23.1.1 adds two practical conditions: the slab must be cast integrally with the web (or effectively bonded to it), and where the main slab steel runs parallel to the beam, transverse steel of at least 60 per cent of the slab's midspan main steel must be provided across the top of the beam.

Derivation

  1. Neutral axis in the flange (xu ≤ Df): 0.36 fck bf xu = 0.87 fy Ast, so xu = 0.87 fy Ast/(0.36 fck bf); if this is not more than Df, Mu = 0.87 fy Ast (d − 0.42 xu), as for a rectangular beam of width bf.
  2. Neutral axis in the web, thin flange (Df/xu ≤ 0.43): the flange outstand carries Cf = 0.45 fck (bf − bw) Df at Df/2 from the top, and the web carries Cw = 0.36 fck bw xu at 0.42 xu. Equilibrium Cw + Cf = 0.87 fy Ast gives xu = (0.87 fy Ast − Cf)/(0.36 fck bw).
  3. Neutral axis in the web, thick flange (Df/xu > 0.43): use yf = 0.15 xu + 0.65 Df (not more than Df) in place of Df; then 0.36 fck bw xu + 0.45 fck (bf − bw)(0.15 xu + 0.65 Df) = 0.87 fy Ast is linear in xu and gives xu directly.
  4. Moment about the steel: Mu = 0.36 fck bw xu (d − 0.42 xu) + 0.45 fck (bf − bw) yf (d − yf/2), with yf = Df in the thin-flange case.
  5. Limiting moment (G-2.2, Df/d ≤ 0.2): Mu,lim = 0.36 (xu,max/d)(1 − 0.42 xu,max/d) fck bw d² + 0.45 fck (bf − bw) Df (d − Df/2); for Df/d > 0.2, Df is replaced by yf with xu = xu,max (G-2.2.1).
  6. Effective width: shear lag makes the flange stress fall away from the web; cl. 23.1.2 replaces it by a uniform stress over bf, which grows with the zero-moment length l0 and the flange thickness and is capped by the actual slab available between beams.
Formulas, symbols and SI units
  • Effective width, T-beam (cl. 23.1.2): bf = l0/6 + bw + 6 Df ≤ bw + half the sum of the clear distances to the adjacent beams (mm)
  • Effective width, L-beam: bf = l0/12 + bw + 3 Df ≤ bw + half the clear distance to the adjacent beam (mm); l0 = 0.7 × effective span for continuous beams
  • Isolated beams: bf = l0/(l0/b + 4) + bw (T) and 0.5 l0/(l0/b + 4) + bw (L), not more than the actual width b (mm)
  • Neutral axis in flange (xu ≤ Df): xu = 0.87 fy Ast/(0.36 fck bf); Mu = 0.87 fy Ast (d − 0.42 xu) (mm; N mm)
  • Neutral axis in web: 0.36 fck bw xu + 0.45 fck (bf − bw) yf = 0.87 fy Ast, yf = Df if Df/xu ≤ 0.43, else yf = 0.15 xu + 0.65 Df ≤ Df (mm)
  • Moment of resistance: Mu = 0.36 fck bw xu (d − 0.42 xu) + 0.45 fck (bf − bw) yf (d − yf/2) (N mm)
  • Minimum tension steel uses the web width: As,min = 0.85 bw d/fy (mm²)
Assumptions and limits
  • The slab is cast integrally with the web, or effectively bonded to it, and transverse steel over the beam meets cl. 23.1.1, so the flange and web act together.
  • The compression in the flange outstand is taken as a uniform 0.45 fck over Df or yf; the web follows the usual stress block of cl. 38.1.
  • The effective-width rules of cl. 23.1.2 apply in the absence of a more accurate determination; bf is a design idealisation of shear lag, not a physical width.
  • The flange is on the compression side, which is true for sagging moments in floor beams; at supports under hogging moment the beam is designed as a rectangle of width bw with the slab steel over the beam counted as tension steel only where it is properly anchored.
  • Limits: the equations assume xu ≤ xu,max; flanged sections with the neutral axis deep in the web and heavy steel must be checked for over-reinforcement like any other section. Very wide or very thin flanges, openings in the slab next to the beam, and precast slabs that are not bonded to the beam need separate consideration.

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • IS 456:2000 cl. 23.1.1 (requirements for a slab to act as a flange: integral casting or effective bond, and transverse reinforcement of at least 60 per cent of the slab's midspan main steel where that steel is parallel to the beam) and cl. 23.1.2 (effective flange width of T-beams, L-beams and isolated beams, with l0 = 0.7 × effective span for continuous beams and frames).
  • IS 456:2000 Annex G, G-2.1 (neutral axis within the flange: rectangular-section equations of G-1.1 with width bf), G-2.2 (Mu,lim when Df/d does not exceed 0.2), G-2.2.1 (yf = 0.15 xu + 0.65 Df, not greater than Df, when Df/d exceeds 0.2) and G-2.3 (sections with xu between Df and xu,max, with the Df/xu = 0.43 condition); cl. 26.5.1.1 (minimum steel with b taken as the web width).
  • Indian, European and American practice are listed side by side and not ranked: the European code (EN 1992-1-1) and the American code (ACI 318) also define an effective flange width from the span, the flange thickness and the spacing of the beams, and design the flanged section by the same equilibrium of a T-shaped compression zone; the width formulas and stress-block factors differ and are not reproduced here.

Worked examples

Example 1 (exam style: effective flange width)

Problem. Continuous floor beams of 8.0 m effective span are spaced at 3.5 m centres, with a web 300 mm wide and a slab 120 mm thick. Find the effective flange width of an internal T-beam and of an edge L-beam. Also find bf for an isolated simply supported T-beam of 5.6 m span with an actual flange width of 1 500 mm and the same web and flange thickness.

  1. Continuous beams: l0 = 0.7 × 8.0 = 5.6 m = 5 600 mm. Clear distance between webs = 3 500 − 300 = 3 200 mm.
  2. T-beam: bf = 5 600/6 + 300 + 6 × 120 = 933 + 300 + 720 = 1 953 mm; the cap is 300 + (3 200 + 3 200)/2 = 3 500 mm, so bf = 1 953 mm.
  3. L-beam: bf = 5 600/12 + 300 + 3 × 120 = 467 + 300 + 360 = 1 127 mm; the cap is 300 + 3 200/2 = 1 900 mm, so bf = 1 127 mm.
  4. Isolated T-beam: bf = 5 600/(5 600/1 500 + 4) + 300 = 5 600/7.733 + 300 = 724 + 300 = 1 024 mm, less than the actual 1 500 mm. (An isolated L-beam of the same size would have 0.5 × 724 + 300 = 662 mm.)

Answer. Internal T-beam bf = 1 953 mm; edge L-beam bf = 1 127 mm; isolated T-beam bf = 1 024 mm

Example 2 (neutral axis in the flange)

Problem. A T-beam has bf = 1 500 mm, bw = 300 mm, Df = 120 mm and d = 500 mm, with four 20 mm Fe 415 bars in M20 concrete. Find the neutral-axis depth and the moment of resistance.

  1. Ast = 1 256.6 mm²; T = 0.87 × 415 × 1 256.6 = 453.7 kN.
  2. Assume the neutral axis is in the flange: xu = 453 700/(0.36 × 20 × 1 500) = 42.0 mm < Df = 120 mm, so the assumption holds.
  3. Mu = 453.7 × (500 − 0.42 × 42.0)/1 000 = 218.8 kN m.
  4. xu/d = 0.084, far below 0.48: very ductile. A rectangular beam of the web width with the same steel would have xu = 210.1 mm and Mu = 186.8 kN m, so the flange adds about 17 per cent here.

Answer. xu = 42 mm (in the flange); Mu = 218.8 kN m

Example 3 (site style: deep neutral axis in a heavily loaded T-beam)

Problem. A transfer beam in a podium slab has bf = 1 000 mm, bw = 250 mm, Df = 100 mm and d = 550 mm, M25 concrete and six 25 mm Fe 500 bars. Find the neutral-axis depth and the moment of resistance, and compare with the limiting moment of the section.

  1. Ast = 2 945.2 mm²; T = 0.87 × 500 × 2 945.2 = 1 281.2 kN. Trial in flange: xu = 1 281 200/(0.36 × 25 × 1 000) = 142.4 mm > Df, so the neutral axis is in the web.
  2. Thin-flange form: xu = (1 281 200 − 0.45 × 25 × 750 × 100)/(0.36 × 25 × 250) = (1 281 200 − 843 750)/2 250 = 194.4 mm; but Df/xu = 0.51 > 0.43, so the yf form applies.
  3. With yf = 0.15 xu + 0.65 Df: 2 250 xu + 8 437.5 (0.15 xu + 65) = 1 281 200, so 3 515.6 xu = 732 760 and xu = 208.4 mm; yf = 31.3 + 65 = 96.3 mm ≤ Df and Df/xu = 0.48 > 0.43 (consistent).
  4. xu,max = 0.46 × 550 = 253 mm, so xu < xu,max: under-reinforced.
  5. Mu = 0.36 × 25 × 250 × 208.4 × (550 − 0.42 × 208.4) + 0.45 × 25 × 750 × 96.3 × (550 − 96.3/2) = 216.9 + 407.6 = 624.5 kN m.
  6. Limiting moment (Df/d = 0.18 ≤ 0.2, G-2.2): 0.1336 × 25 × 250 × 550² + 0.45 × 25 × 750 × 100 × (550 − 50) = 252.6 + 421.9 = 674.5 kN m; the beam works at about 93 per cent of it.

Answer. Neutral axis in the web, xu = 208 mm (yf = 96 mm); Mu = 624.5 kN m against Mu,lim = 674.5 kN m

Step-by-step procedure

  1. Decide whether the section is in sagging (flange in compression) or hogging (design as a rectangle of width bw).
  2. Find l0 and the effective width bf from cl. 23.1.2, applying the cap from the actual slab available.
  3. Assume the neutral axis is in the flange and compute xu = 0.87 fy Ast/(0.36 fck bf); if xu ≤ Df, use the rectangular equations with width bf.
  4. Otherwise solve the web case: try yf = Df; if Df/xu exceeds 0.43, use yf = 0.15 xu + 0.65 Df and solve again.
  5. Check xu ≤ xu,max and compute Mu; for design, start from Ast ≈ Mu/(0.87 fy (d − Df/2)) and refine.
  6. Check minimum steel with bw, the cl. 23.1.1 transverse steel over the beam, and then shear, which is resisted by the web alone.

Site notes

  • The T-beam action only exists if the slab and beam are cast together or properly bonded; a construction joint between beam and slab must be prepared as the drawings show, or the flange is lost.
  • Transverse bars across the top of the beam (cl. 23.1.1) are easily forgotten when the slab main steel runs parallel to the beam; check them at the pour inspection.
  • Openings or ducts cut in the slab next to a beam reduce its effective flange; any new opening near a beam needs a design check.
  • At supports the hogging steel in the slab over the beam is tension steel for the beam too; it must be anchored as detailed.
  • Shear is carried by the web; a wide flange does not reduce the stirrups required.
Common mistakes
  • Using the full beam spacing as bf instead of the cl. 23.1.2 effective width.
  • Treating the beam as a T-section at a support where the flange is in tension.
  • Using bf instead of bw in the minimum-steel check or in the web part of the stress block.
  • Taking the flange stress over the full Df when Df/xu exceeds 0.43 without using yf.
  • Forgetting that l0 is the distance between points of zero moment (0.7 × span for continuous beams), not the full span.
Quick check

Under sagging moment most floor T-beams have the neutral axis within the flange, because bf is several times bw. A good first estimate of the steel is Ast ≈ Mu/(0.87 fy (d − Df/2)), which was within about 10 per cent of the exact value in both section examples of this lesson; if xu from the flange check comes out larger than Df, switch to the web equations. In Example 1 the internal T-beam flange is about 6.5 times the web width.

Summary

  • A beam cast with a slab acts as a T-beam (internal) or L-beam (edge) under sagging moment; under hogging it is a rectangle of width bw.
  • IS 456:2000 cl. 23.1.2 gives bf = l0/6 + bw + 6 Df (T) and l0/12 + bw + 3 Df (L), capped by the slab available, with l0 = 0.7 × span for continuous beams, and separate formulas for isolated beams.
  • If xu ≤ Df the section is a rectangle of width bf (Annex G, G-2.1).
  • If xu > Df the web carries 0.36 fck bw xu and the flange outstand 0.45 fck (bf − bw) yf, with yf = Df when Df/xu ≤ 0.43 and yf = 0.15 xu + 0.65 Df otherwise (G-2.2, G-2.2.1, G-2.3).
  • Cl. 23.1.1 requires the slab to be integral with the web and, where its main steel is parallel to the beam, transverse steel of at least 60 per cent of that steel over the beam.

Practice questions

Tap a question to see the answer.

1Find bf for a simply supported internal T-beam of 4.2 m span (l0 = 4.2 m), bw = 230 mm, Df = 110 mm, beams at 3.0 m centres.

bf = 4 200/6 + 230 + 6 × 110 = 700 + 230 + 660 = 1 590 mm, below the cap 230 + 2 770 = 3 000 mm.

2Find bf for the matching edge L-beam.

bf = 4 200/12 + 230 + 3 × 110 = 350 + 230 + 330 = 910 mm, below the cap 230 + 1 385 = 1 615 mm.

3A T-beam has bf = 1 200 mm, Df = 100 mm, M20 and Fe 415 with Ast = 1 500 mm². Is the neutral axis in the flange?

xu = 0.87 × 415 × 1 500/(0.36 × 20 × 1 200) = 62.7 mm < 100 mm: yes.

4Where does the 0.43 in the Df/xu condition come from?

It is 3/7: the concrete stress is uniform over the top 3/7 of the neutral-axis depth, so a flange thinner than that lies wholly in the uniform-stress zone.

5Find Mu,lim for bf = 1 500 mm, bw = 300 mm, Df = 120 mm, d = 500 mm, M20 and Fe 415.

Df/d = 0.24 > 0.2, so yf = 0.15 × 240 + 0.65 × 120 = 114 mm; Mu,lim = 0.138 × 20 × 300 × 500² + 0.45 × 20 × 1 200 × 114 × (500 − 57) = 206.9 + 545.4 = 752.3 kN m.

6Which width is used for the minimum tension steel of a T-beam, and why?

The web width bw: cl. 26.5.1.1 defines b as the breadth of the web for T-beams, because the tension zone that cracks is in the web.

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • S. U. Pillai, D. Menon, Reinforced Concrete Design, Tata McGraw Hill (now McGraw Hill Education (India)), 3rd edition, 2009.
  • P. C. Varghese, Limit State Design of Reinforced Concrete, Prentice Hall of India (PHI Learning), 2nd edition, 2008.
  • J. K. Wight, J. G. MacGregor, Reinforced Concrete: Mechanics and Design, Pearson, 6th edition, 2012.
  • R. Park, T. Paulay, Reinforced Concrete Structures, John Wiley and Sons, 1975.
Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.

Sent privately to the Indiacon editor; not published.