Indiacon CivilSubscribe

Textbook › Fluid Mechanics › Chapter 2 › Lesson 2.1

2.1 Pressure and its measurement

Fluid Mechanics Chapter 2: Fluid statics Under review — not yet three-checked Author: Indiacon

Learning objectives

After this lesson you should be able to:

  • State Pascal’s law, write the hydrostatic law p = p0 + ρ g h for an incompressible liquid, and compute the pressure at a depth in a liquid using the civil convention ρ = 1000 kg/m³ and g = 9.81 m/s².
  • Distinguish absolute, gauge and vacuum pressure, and convert between them using the official standard atmosphere 101.325 kPa when that reference is chosen.
  • Use a piezometer and a U-tube manometer, including a differential mercury manometer with the labelled working density 13 600 kg/m³, to find a pressure or a pressure difference.
  • Explain why a 760 mm mercury column computed with the working density and g = 9.81 m/s² is not the official 101.325 kPa standard atmosphere, and name the common instruments used when a manometer is not suitable.

Theory

A fluid at rest cannot carry a shear stress that lasts: any such stress would make it flow. The only contact stress that remains, in a static fluid, is a compressive pressure that acts equally in all directions at a point. That is Pascal’s law, and it is why a pressure applied to a confined liquid is felt, undiminished, at every point of the container (allowing for the hydrostatic variation with depth). Civil work meets this every day in a reservoir, a standpipe, a borehole, a jack and a manometer. This lesson is about that pressure, how it varies with depth, and how it is measured. Density was Lesson 1.1; the force that the same pressure exerts on a gate or a wall is Lesson 2.2.

For an incompressible liquid of density ρ in a gravitational field of intensity g, a vertical balance on a thin slice gives the hydrostatic law dp/dz = −ρ g, or, with h measured downward from a free surface at pressure p0, p = p0 + ρ g h. The quantity ρ g is the specific weight γ already used in Lesson 1.1. With the civil convention ρ = 1000 kg/m³ and g = 9.81 m/s², each metre of water depth is 9.81 kPa of pressure. The law is for a connected static liquid of constant density. It does not apply unchanged across a free surface, through a gas whose density itself depends on the pressure, or along a flow in which the fluid is moving (that is Bernoulli’s equation, a later chapter). If two immiscible liquids are stacked, the same law is applied, layer by layer, using each layer’s own density.

Pressure and its measurementfree surfaceA, depth hp = p0 + ρghpiezometerrise h = p_g/ρgU-tubeΔhmercury, working 13600 kg/m3p_abs = p_gauge + p_atm; vacuum = p_atm - p_absIndiacon original, not to scale
Figure 2.1: Hydrostatic pressure in an open tank, a piezometer and a mercury U-tube, with the absolute–gauge–vacuum relation. Indiacon original, not to scale.

Pressure may be reported as absolute, gauge or vacuum. Absolute pressure p_abs is measured from a true zero (a perfect vacuum). Gauge pressure p_g is the amount by which the absolute pressure exceeds the local atmospheric pressure, p_g = p_abs − p_atm. A vacuum reading is the amount by which the atmospheric pressure exceeds the absolute pressure, p_vac = p_atm − p_abs, and is used only when p_abs is below p_atm. Most civil gauges, including Bourdon gauges and ordinary manometers open to the air, read a gauge pressure; atmospheric pressure itself is then the datum, not the number 101.325 kPa. When an absolute pressure is required — for example to compare a pump inlet with a vapour pressure, as in Lesson 1.2 — a value of p_atm must be stated. In the examples, when that conversion is needed, p_atm is taken as the official standard atmosphere 101.325 kPa (exactly 101 325 Pa). That is the reference pressure p0 of ISO 2533 (Standard Atmosphere), and it is the same p0 = 0.101 325 MPa already used with the CIPM and IAPWS water-property statements in Lessons 1.1 and 1.2. It is a defined reference, not a claim that the barometer on a particular site reads 101.325 kPa. Site atmospheric pressure varies with altitude and weather; a precise conversion uses the barometer reading, not the standard atmosphere.

The simplest measuring instrument is a piezometer: an open vertical tube in which the liquid rises until ρ g h equals the gauge pressure in the pipe. It is direct and has no moving parts, but it is bulky for high pressures (a 50 m rise of water is 490.5 kPa), it cannot read a vacuum or a gas pressure without flooding, and a thin tube is affected by capillarity (Lesson 1.1). A U-tube manometer avoids some of those limits by using a denser indicating liquid, most often mercury, so that a modest column height balances a larger pressure. For a differential mercury manometer between two water pipes at the same level, with a difference h in the mercury surfaces, the pressure difference is Δp = (ρ_Hg − ρ_w) g h. The working density of mercury used in the examples is 13 600 kg/m³, a rounded textbook figure consistent with White and with Munson, Young, Okiishi and Huebsch, and it is labelled as such. It is not the conventional 13 595.1 kg/m³ which, together with the standard gravity 9.80665 m/s², makes a 760 mm mercury column equal to the official 101 325 Pa. With the working values of this lesson, 760 mm of mercury is 13 600 × 9.81 × 0.760 = 101.396 kPa, which must not be reported as 101.325 kPa. An inclined manometer stretches a small pressure into a longer travel along the tube: if the tube is inclined at an angle θ to the horizontal and the liquid travels a distance L along the tube, the vertical rise is L sin θ and p_g = ρ g L sin θ. For pressures that are too high, too low, or varying too quickly for a liquid column, a Bourdon gauge, a diaphragm or an electronic transducer is used; those instruments are named here so that they can be recognised, and they are calibrated against a known pressure, not derived in this lesson.

Derivation

  1. A vertical prism of liquid, height δh, area A, has weight ρ g A δh. In a static fluid the shear is zero, so vertical equilibrium requires the pressure on the lower face to exceed the pressure on the upper face by that weight divided by A, which is ρ g δh. Integrating downward from a surface at pressure p0 gives p = p0 + ρ g h for constant ρ. This is the hydrostatic law used in every example.
  2. By definition, p_abs = p_g + p_atm and p_vac = p_atm − p_abs. When the official standard atmosphere is chosen as the reference, p_atm = 101.325 kPa exactly. A site conversion should use the local barometer instead.
  3. Piezometer: the liquid column is open to the atmosphere, so p_g = ρ g h, or h = p_g / (ρ g).
  4. Differential mercury U-tube between two water pipes at the same elevation, mercury-level difference h: starting at one pipe, drop through a water leg, then through the mercury difference, then up a water leg to the other pipe. The water legs of equal height cancel, and Δp = (ρ_Hg − ρ_w) g h. If the indicating liquid is the same as the pipe liquid, this difference vanishes and the device does not read a pressure difference between two points at the same level.
  5. Inclined manometer: the vertical rise is L sin θ, so p_g = ρ g L sin θ.
  6. A 760 mm mercury column with the working values is p = 13 600 kg/m³ × 9.81 m/s² × 0.760 m = 101.396 kPa, which is not the official standard atmosphere 101.325 kPa.
Formulas, symbols and SI units
  • Hydrostatic law, constant density: p = p0 + ρ g h (Pa), with h downward from the surface at p0
  • Civil working values in the examples: ρ_w = 1000 kg/m³, g = 9.81 m/s², so γ_w = 9.81 kN/m³ and 1 m of water = 9.81 kPa
  • p_abs = p_g + p_atm; p_vac = p_atm − p_abs
  • Official standard atmosphere used for conversion in the examples: p_atm = 101.325 kPa exactly (ISO 2533 p0; same p0 as in Lessons 1.1–1.2)
  • Piezometer: p_g = ρ g h
  • Differential mercury manometer, same-level water pipes: Δp = (ρ_Hg − ρ_w) g h
  • Working mercury density in the examples: ρ_Hg = 13 600 kg/m³ (labelled textbook figure). With these working values, 760 mm of mercury = 101.396 kPa, not 101.325 kPa
  • Inclined manometer: p_g = ρ g L sin θ
Assumptions and limits
  • The hydrostatic law as written is for a static, incompressible liquid of constant density, connected as a single body. It is applied layer by layer if the densities differ.
  • The examples use ρ_w = 1000 kg/m³ and g = 9.81 m/s² unless a problem states another value. These are the Lesson 1.1 civil conventions, not the CIPM maximum-density value.
  • The mercury density 13 600 kg/m³ is a labelled textbook working value. It is not to be mixed, in the same arithmetic, with the official 101.325 kPa standard atmosphere as if 760 mm of that working mercury column were exactly one standard atmosphere.
  • When a gauge pressure is converted to an absolute pressure in the examples, p_atm is taken as 101.325 kPa. A site conversion should use the local barometer.
  • Capillarity, temperature change of density, and the weight of the air column in a long limb are ignored unless a problem states them.
  • This lesson does not calibrate a Bourdon gauge, does not compute a site barometer correction for altitude, and does not rank instrument standards.

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • ISO 2533, Standard Atmosphere — official reference pressure p0 = 101 325 Pa. The same numerical value is the p0 already used with CIPM/IAPWS water properties in Lessons 1.1 and 1.2.
  • BIPM SI Brochure (9th edition, 2019) — SI units of pressure (the pascal, 1 Pa = 1 N/m²). The bar (1 bar = 10⁵ Pa exactly) is a unit used alongside SI; it is not an SI unit.
  • No Indian Standard clause is used for the hydrostatic law or for the manometer formulae; those are continuum mechanics. Instrument specifications (for example for a particular Bourdon gauge) are not cited, because official texts of those specifications were not on the box at writing.
  • Background textbooks, not ranked: F. M. White, Fluid Mechanics; B. R. Munson, D. F. Young, T. H. Okiishi, W. W. Huebsch, Fundamentals of Fluid Mechanics.

Worked examples

Example 1 (illustrative): gauge and absolute pressure at a depth

Problem. A tank of water has a free surface open to the atmosphere. Point A is 4.50 m below the free surface. Taking ρ = 1000 kg/m³ and g = 9.81 m/s², find the gauge pressure at A. Then, taking p_atm as the official standard atmosphere 101.325 kPa, find the absolute pressure at A. If the tank is now closed and the free-surface gauge pressure is 50.00 kPa, what are the gauge and absolute pressures at A, with the same p_atm?

  1. In the open tank the free-surface gauge pressure is zero, so p_g,A = ρ g h = 1000 × 9.81 × 4.50 = 44 145 Pa = 44.145 kPa.
  2. Absolute pressure p_abs,A = p_g,A + p_atm = 44.145 + 101.325 = 145.470 kPa.
  3. When the tank is closed and the free-surface gauge pressure is 50.00 kPa, the hydrostatic law adds the same 44.145 kPa of liquid head: p_g,A = 50.00 + 44.145 = 94.145 kPa.
  4. Absolute pressure p_abs,A = 94.145 + 101.325 = 195.470 kPa. The 101.325 kPa figure is the official standard atmosphere used as a reference, not a measured barometer reading on the site.

Answer. Open tank: p_g = 44.145 kPa, p_abs = 145.470 kPa. Closed tank with 50.00 kPa surface gauge: p_g = 94.145 kPa, p_abs = 195.470 kPa.

Example 2 (illustrative): differential mercury manometer between two water pipes

Problem. Two water pipes, at the same elevation, are connected by a mercury U-tube. The mercury surface on the right stands 200 mm above the mercury surface on the left. Taking the textbook working density ρ_Hg = 13 600 kg/m³, with ρ_w = 1000 kg/m³ and g = 9.81 m/s², find the pressure difference p_left − p_right in kPa. Then say, in one sentence, why a 760 mm column of this working mercury is not to be reported as 101.325 kPa.

  1. The pipes are at the same level, so the water legs of equal height cancel and Δp = (ρ_Hg − ρ_w) g h.
  2. h = 200 mm = 0.200 m. ρ_Hg − ρ_w = 13 600 − 1 000 = 12 600 kg/m³.
  3. Δp = 12 600 × 9.81 × 0.200 = 24 721.2 Pa = 24.721 kPa. The left-hand pipe is at the higher pressure: it pushes the mercury down in its own limb, so the mercury stands higher in the right-hand limb.
  4. With the same working values, a 760 mm mercury column would be 13 600 × 9.81 × 0.760 = 101.396 kPa, which is not the official standard atmosphere 101.325 kPa. The official 101.325 kPa corresponds to 760 mm of mercury only when the conventional density 13 595.1 kg/m³ and the standard gravity 9.80665 m/s² are used together. Those conventional constants are not the working values of this example.

Answer. p_left − p_right = 24.721 kPa. A 760 mm column of the working mercury is 101.396 kPa, not the official 101.325 kPa standard atmosphere.

Step-by-step procedure

  1. State whether the required pressure is gauge, absolute or vacuum, and write down the datum (local atmosphere, or the official standard atmosphere, or a stated barometer).
  2. For a depth in a single liquid, apply p = p0 + ρ g h, with h measured downward from the surface whose pressure is p0. Use the civil conventions ρ = 1000 kg/m³ and g = 9.81 m/s² unless the problem states other values.
  3. If there are two liquids, write the hydrostatic law through each limb, layer by layer, until the two paths meet, and collect the pressure difference.
  4. For a piezometer, convert the rise directly: p_g = ρ g h. For an inclined tube, use the vertical component L sin θ.
  5. For a mercury U-tube between water pipes at the same level, use Δp = (ρ_Hg − ρ_w) g h, and state that ρ_Hg is the working 13 600 kg/m³ if that is the value used. Do not convert that column to “atmospheres” by dividing by 101.325 kPa as if the working mercury were the conventional 760 mm atmosphere.
  6. When an absolute pressure is needed (for example a cavitation check), add the stated p_atm. If no site barometer is given, say that the official standard atmosphere 101.325 kPa is being used as a reference.
  7. If the pressure is outside the convenient range of a liquid column, use a calibrated Bourdon gauge or transducer; do not invent a manometer height that will not fit on the site.

Site notes

  • A piezometer on a pump discharge can be several metres tall. Put it where it can be read, and trap air out of the tube before trusting the rise.
  • Mercury is a hazard. Many site manometers now use a dense indicating oil of stated specific gravity; use that stated density, not 13 600 kg/m³.
  • If one limb of a U-tube is not at the same pipe elevation as the other, include the water-leg difference; forgetting it is a common error on a crowded pipe rack.
  • A Bourdon gauge reads gauge pressure. Writing its reading as an absolute pressure, or comparing it directly with a vapour pressure without adding p_atm, will mislead a cavitation check.
  • Atmospheric pressure falls with altitude. A conversion that always uses 101.325 kPa will be wrong on a high-altitude site if an absolute pressure is really required; use the local barometer.
  • Temperature changes the density of the indicating liquid a little. For ordinary civil readings the working densities of this lesson are enough; for a calibration bench, use the density at the measured temperature.
Common mistakes
  • Adding ρ g h to a gauge pressure and calling the result absolute, or forgetting to add p_atm when an absolute pressure is required.
  • Using p_abs = p_g + 100 kPa, or p_g + 1 bar, and calling it the official standard atmosphere. The official value used in this lesson is 101.325 kPa, and 1 bar is 100 kPa exactly, which is a different unit.
  • Writing Δp = ρ_Hg g h for a mercury U-tube between two water pipes, and forgetting to subtract ρ_w g h.
  • Reporting a 760 mm column of the working mercury (13 600 kg/m³, g = 9.81 m/s²) as 101.325 kPa. That arithmetic gives 101.396 kPa.
  • Taking a piezometer rise as an absolute pressure, or using a piezometer to “measure a vacuum”.
  • Mixing the CIPM density of water, the 1000 kg/m³ convention, and a stated 998 kg/m³ in the same sum without a reason.
  • Treating a Bourdon-gauge reading as if it already included atmospheric pressure.
Quick check

p = p0 + ρgh (static, constant ρ). Civil water: ρ = 1000 kg/m³, g = 9.81 m/s², so 1 m of water = 9.81 kPa. p_abs = p_g + p_atm, with p_atm = 101.325 kPa when the official standard atmosphere is the reference. Mercury U-tube, same-level water pipes: Δp = (ρ_Hg − ρ_w)gh, with working ρ_Hg = 13 600 kg/m³. Do not treat 760 mm of that working mercury as 101.325 kPa.

Summary

  • In a static liquid of constant density, pressure increases with depth as p = p0 + ρ g h. This follows from vertical equilibrium and Pascal’s law.
  • Gauge, absolute and vacuum pressures differ only in their datum. The official standard atmosphere used for conversions in this lesson is 101.325 kPa; a site conversion should use the local barometer.
  • A piezometer reads p_g = ρ g h. A differential mercury manometer between same-level water pipes reads Δp = (ρ_Hg − ρ_w) g h. The working mercury density 13 600 kg/m³ is a labelled textbook figure.
  • A 760 mm column of that working mercury is 101.396 kPa, not the official 101.325 kPa standard atmosphere.
  • High, low or rapidly changing pressures are read with a calibrated Bourdon gauge or transducer, not with an inconveniently tall liquid column.

Practice questions

Tap a question to see the answer.

1What is the gauge pressure 3.00 m below the free surface of an open water tank, with ρ = 1000 kg/m³ and g = 9.81 m/s²?

p_g = 1000 × 9.81 × 3.00 = 29.43 kPa.

2A gauge reads 40.00 kPa absolute. Taking p_atm = 101.325 kPa, what is the vacuum reading?

p_vac = 101.325 − 40.00 = 61.325 kPa.

3A water piezometer rises 2.50 m. What gauge pressure does it read, with ρ = 1000 kg/m³ and g = 9.81 m/s²?

p_g = 1000 × 9.81 × 2.50 = 24.525 kPa.

4An inclined water manometer has L = 0.40 m along the tube at θ = 30° to the horizontal. What gauge pressure does it read, with ρ = 1000 kg/m³ and g = 9.81 m/s²?

p_g = 1000 × 9.81 × 0.40 × sin 30° = 1 962 Pa = 1.962 kPa.

5Why must a 760 mm mercury column computed with ρ_Hg = 13 600 kg/m³ and g = 9.81 m/s² not be reported as 101.325 kPa?

Because that arithmetic gives 101.396 kPa. The official 101.325 kPa standard atmosphere corresponds to 760 mm of mercury only with the conventional density 13 595.1 kg/m³ and standard gravity 9.80665 m/s².

6Two water pipes at the same level are connected by a mercury U-tube with a 100 mm mercury difference. Using the working ρ_Hg = 13 600 kg/m³, ρ_w = 1000 kg/m³ and g = 9.81 m/s², what is Δp?

Δp = (13 600 − 1 000) × 9.81 × 0.100 = 12 360.6 Pa = 12.361 kPa.

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • F. M. White, Fluid Mechanics, McGraw Hill, 8th edition, 2016.
  • B. R. Munson, D. F. Young, T. H. Okiishi, W. W. Huebsch, Fundamentals of Fluid Mechanics, Wiley, 8th edition, 2016.
  • ISO 2533, Standard Atmosphere, official reference pressure p0 = 101 325 Pa. BIPM, The International System of Units (SI Brochure), 9th edition, 2019.
Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.