1.2 Compressibility and vapour pressure
After this lesson you should be able to:
- Define the bulk modulus of elasticity and the coefficient of compressibility, state their SI units, and use them to compute a volume change under a pressure change.
- Relate the isentropic bulk modulus of a fluid to the speed of sound, and distinguish a precise IAPWS verification point at 300 K from the civil working value K = 2.2 GPa.
- Define vapour pressure and explain cavitation as the formation of vapour where the local liquid pressure reaches the vapour pressure at that temperature.
- Apply a stated working vapour pressure at 20 °C to a cavitation check, and say why a higher temperature makes cavitation more likely.
Theory
Liquids are often called incompressible in everyday civil work, and that is a useful first approximation for many steady pipeline and open-channel calculations. It is not exactly true. A large pressure change produces a small volume change in a liquid, and that small change is what matters in water hammer, in the stiffness of a closed water main, and in the speed of a pressure wave. Gases, by contrast, change volume readily. This lesson is about that difference, and about the other liquid property that appears when the pressure gets very low: vapour pressure. Density and viscosity were Lesson 1.1; water hammer as a pipeline problem is a later hydraulics lesson.
The bulk modulus of elasticity K (sometimes written Ev) is the ratio of a pressure increase to the fractional decrease in volume, K = − dp / (dV / V). The SI unit is the pascal, and values for liquids are usually written in GPa or N/mm². The minus sign makes K positive, because an increase in pressure decreases the volume. The coefficient of compressibility is the reciprocal, β = 1 / K = − (1/V) dV/dp, in Pa⁻¹. For a finite but still modest change, ΔV = − V Δp / K, provided K can be treated as constant over that range. A gas at ordinary pressure has a K of the same order as the pressure itself (for an ideal gas in an isothermal change, K = p); a liquid has a K of the order of gigapascals, so its volume change is thousands of times smaller.
For liquid water, civil calculations commonly use a textbook working value K = 2.2 GPa at ordinary temperature, together with the conventional density 1000 kg/m³ of Lesson 1.1. That 2.2 GPa figure is not a code limit and is not an IAPWS table entry; it is a rounded working value used in White and in Munson, Young and Okiishi, and it is labelled as such in the examples. A precise, official check point is given in IAPWS R6-95(2018), Table 7: at T = 300 K and ρ = 996.5560 kg/m³, the pressure is 0.0992418352 MPa and the speed of sound is w = 1501.51914 m/s. The isentropic bulk modulus at that state is Ks = ρ w² = 2.247 GPa. The civil working value 2.2 GPa is a rounded figure near that order, not a substitute for the official point when a precise property is required. K also changes with temperature, pressure and air content: entrained air in a pipeline can lower the effective bulk modulus by a large factor, which is why a “water” hammer calculation on a gassy main is not the same as one on de-aerated water.
The speed of a small pressure wave (the speed of sound) in a fluid of density ρ, when the pipe or container is treated as rigid, is c = √(Ks / ρ), where Ks is the isentropic bulk modulus. With the working values K = 2.2 GPa and ρ = 1000 kg/m³ this is c = 1 483 m/s. The official IAPWS point above gives 1 501.5 m/s at 300 K for that particular density. In a real pipe the wall expands a little and the effective wave speed is lower; that correction belongs with water hammer, not with this lesson. The same formula is the reason a liquid wave travels about four to five times as fast as a sound wave in air.
Vapour pressure pv is the pressure at which a liquid is in equilibrium with its own vapour at a given temperature. If the pressure in a liquid is reduced, at constant temperature, to pv, the liquid starts to form vapour. For water, pv rises strongly with temperature: it is a small fraction of an atmosphere at ordinary room temperature, and it reaches one standard atmosphere at the ordinary boiling point. In the examples, a stated working value pv = 2.34 kPa at 20 °C is used. That is a rounded textbook figure, consistent with the fluid-mechanics tables in White and in Munson et al., not a copied official table entry. The official saturation formulation for water is IAPWS R6-95(2018); a set of simpler equations is given in IAPWS SR1-86(1992) and agrees with R6-95 within the uncertainties stated for those simpler equations. The conventional teaching picture that water boils at 100 °C when the pressure is 101.325 kPa is the everyday civil picture; the precise IAPWS saturation temperature at 101.325 kPa is very slightly below 100 °C. The two must not be mixed in a calculation that claims official precision.
Cavitation occurs when the local pressure in a flowing liquid falls to the vapour pressure. Vapour bubbles form and then collapse when they are carried into a region of higher pressure. The collapse can pit metal, throw a pump off its duty, and make a sharp noise. A constriction in a pipe, the suction side of a pump, and the tip of a fast propeller are the usual civil and mechanical places to look. A simple check is to compare the lowest expected absolute pressure with pv at the liquid temperature. If p_min is close to or below pv, cavitation is expected. Because pv rises with temperature, the same suction pressure may be safe on a cold morning and unsafe in a warm afternoon. A related quantity, net positive suction head, is how pump manufacturers turn this check into a rated margin; it is named only so that it can be found later, and is not computed in this lesson.
Derivation
- Start from the definition K = − dp / (dV / V). For a finite change with K treated as constant, rearrange to ΔV = − V Δp / K. The coefficient of compressibility is the reciprocal, β = 1/K, so ΔV = − V β Δp.
- A small isentropic pressure wave travels at c = √(Ks / ρ). This follows from the one-dimensional momentum and continuity equations for a small disturbance in a compressible fluid (or, equivalently, from c² = dp/dρ at constant entropy, together with Ks = ρ dp/dρ). If the container is not rigid, an effective K lower than the fluid’s own Ks is used; that step is left to water hammer.
- At the official IAPWS R6-95(2018) Table 7 point T = 300 K, ρ = 996.5560 kg/m³, w = 1501.51914 m/s, the isentropic bulk modulus is Ks = ρ w². Substituting the official figures gives Ks = 2.247 GPa, which is used only as a check on the order of the working value, not in the numerical examples.
- With the civil working values K = 2.2 × 10⁹ Pa and ρ = 1000 kg/m³, c = √(K / ρ) = √(2.2 × 10⁶) = 1 483 m/s.
- Cavitation is expected where the local absolute pressure p is at or below the vapour pressure pv(T) at the local temperature. A margin may be written as p − pv. The margin has the units of pressure; it is not a code factor in this lesson.
K = − dp / (dV / V) (Pa or GPa); β = 1/K (Pa⁻¹)ΔV = − V Δp / K (for constant K over the change)c = √(Ks / ρ) (m/s) in a rigid containerWorking values in the examples: K = 2.2 GPa, ρ = 1000 kg/m³, so c = 1 483 m/s. These are labelled textbook working values, not IAPWS table entries.Official check (IAPWS R6-95(2018) Table 7): T = 300 K, ρ = 996.5560 kg/m³, w = 1501.51914 m/s, hence Ks = ρ w² = 2.247 GPa.Working vapour pressure in the examples: pv = 2.34 kPa at 20 °C (rounded textbook figure). Cavitation where p ≤ pv(T).
- The finite-change formula ΔV = − V Δp / K treats K as constant and the mass as fixed. It is for a modest pressure change in a single-phase liquid, not for a gas being compressed through a large ratio, and not for a liquid that has already started to vaporise.
- The civil working value K = 2.2 GPa, and the working vapour pressure 2.34 kPa at 20 °C, are rounded textbook figures. They are not official IAPWS table entries and are not to be mixed with the official 300 K verification point in the same arithmetic without a reason.
- c = √(Ks / ρ) is for a rigid container or an unbounded fluid. A real pipe wall lowers the wave speed.
- Entrained air, dissolved gas coming out of solution, and a change of temperature all change the effective K and the vapour pressure. The examples ignore dissolved gas unless a problem states it.
- The cavitation check compares a stated local absolute pressure with pv. It is not a complete pump-inlet or orifice analysis, and it does not compute net positive suction head.
- g and the 1000 kg/m³ convention are those of Lesson 1.1, unless a problem states another density.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- IAPWS R6-95(2018), Revised Release on the IAPWS Formulation 1995 for the Thermodynamic Properties of Ordinary Water Substance for General and Scientific Use — official verification point in Table 7 as used above; official saturation formulation. IAPWS SR1-86(1992) is the simpler saturation-property release, noted as agreeing with R6-95 within its stated uncertainties.
- IAPWS G5-01 (2026 revision) and the CIPM maximum-density value used in Lesson 1.1 are not re-used as a bulk modulus.
- No Indian Standard is required for these definitions. IS 1172 and pump or pipeline codes that mention cavitation or water hammer are not used in this lesson.
- ISO 80000 (quantities and units) is named for comparison of units only, not ranked.
Worked examples
Problem. A rigid, closed tank holds 2.00 m³ of water. The pressure is raised by 5.00 MPa. Taking the textbook working value K = 2.2 GPa, find the change in volume, in cubic metres and in litres. Say, in one sentence, how this K differs from the IAPWS R6-95 Table 7 check point at 300 K.
- K = 2.2 GPa = 2.2 × 10⁹ Pa. The pressure rise is Δp = 5.00 × 10⁶ Pa.
- ΔV = − V Δp / K = − 2.00 × (5.00 × 10⁶) / (2.2 × 10⁹) = − 10.00 × 10⁶ / 2.2 × 10⁹ = − 4.545 × 10⁻³ m³.
- In litres, ΔV = − 4.545 L. The volume decreases, as it must under a pressure rise.
- The 2.2 GPa figure is a rounded textbook working value. At the official IAPWS R6-95(2018) Table 7 point T = 300 K, ρ = 996.5560 kg/m³, the speed of sound is 1501.51914 m/s and Ks = ρ w² = 2.247 GPa, which is of the same order but is not the number used in this arithmetic.
Answer. ΔV = −4.545 × 10⁻³ m³, or −4.545 L. The 2.2 GPa value is a textbook working value, not the official 2.247 GPa IAPWS check point at 300 K.
Problem. (a) Using the same working values K = 2.2 GPa and ρ = 1000 kg/m³, compute the speed of sound in the water, treating the container as rigid. (b) At a pump inlet the absolute pressure is 8.00 kPa and the water temperature is 20 °C. Taking the stated working value pv = 2.34 kPa at 20 °C, does the inlet cavitate, and what is the pressure margin? (c) If the water warms so that pv becomes 8.00 kPa, what happens to that margin?
- c = √(K / ρ) = √(2.2 × 10⁹ / 1000) = √(2.2 × 10⁶) = 1 483 m/s.
- The inlet pressure 8.00 kPa is above pv = 2.34 kPa, so the water is not at boiling conditions at the inlet on this check. The margin is 8.00 − 2.34 = 5.66 kPa.
- The margin is small compared with atmospheric pressure (about 101 kPa). A further drop in inlet pressure, or a rise in temperature, can close it.
- If pv rises to 8.00 kPa, the margin is 8.00 − 8.00 = 0. The liquid is then at its vapour pressure and cavitation is expected at the inlet.
- The 2.34 kPa figure is a stated working value at 20 °C, not an official IAPWS table entry. A precise saturation pressure should be taken from the IAPWS formulation when a calculation claims that precision.
Answer. c = 1 483 m/s. At 20 °C the inlet does not cavitate on this check; the margin is 5.66 kPa. If pv rises to 8.00 kPa the margin is zero and cavitation is expected.
Step-by-step procedure
- Write V, Δp and K in consistent SI units (MPa to Pa, GPa to Pa, litres to m³).
- Decide whether a working value of K (2.2 GPa in this lesson) or a precise official property (the IAPWS Table 7 point, or a stated value) is required. Do not mix them in one line of arithmetic without saying so.
- Compute ΔV = − V Δp / K, and report the sign (a pressure rise decreases the volume).
- If a wave speed is asked and the container is rigid, compute c = √(K / ρ) with the same K and a stated density (1 000 kg/m³ in the examples).
- For a cavitation check, convert all pressures to the same units and to an absolute basis, take pv at the actual liquid temperature, and compare p_min with pv. Report the margin p_min − pv.
- If the temperature may change, say so: pv rises with temperature, and a margin that was acceptable when cold may not be acceptable when warm.
- State that the working values are textbook figures whenever they are used.
Site notes
- A pressure-wave calculation on a long rising main must eventually include the pipe-wall elasticity and any dissolved or entrained air. Using 1 483 m/s as if the main were rigid and de-aerated is only a first upper-bound figure.
- Pump suction pipework, a partially closed valve, and a sharp constriction are the first places to look if a pump rattles or a valve sings. Measure or estimate the local absolute pressure and the water temperature, not just the gauge pressure at a distant tap.
- Warm water cavitates more readily than cold water at the same suction pressure, because pv is higher. A test on a cool morning is not a complete check for a hot afternoon.
- A closed heating or chilled-water circuit that is over-pressurised by thermal expansion is a bulk-modulus problem as well as a relief-valve problem: the volume change is small, but the pressure change can be large if the circuit is completely liquid-filled and closed.
- Do not use the vapour-pressure working value at 20 °C for steam, for a cooling-tower basin in summer, or for a calculation that claims official IAPWS precision.
- Using K = 2.2 Pa, or 2.2 MPa, instead of 2.2 GPa (off by a factor of a thousand or a billion), or treating 2.2 GPa as 2.2 × 10⁶ Pa.
- Forgetting the minus sign and reporting a volume increase under a pressure rise.
- Mixing the official IAPWS 300 K check point (Ks = 2.247 GPa, c = 1501.5 m/s) with the 2.2 GPa / 1 483 m/s working values in the same arithmetic.
- Comparing a gauge pressure with pv, or using pv at the wrong temperature, in a cavitation check.
- Taking the conventional 100 °C / 101.325 kPa boiling picture as an official IAPWS saturation point at exactly 100.000 °C.
- Using a liquid wave speed of about 340 m/s (the speed of sound in air) in a water-hammer estimate.
- Treating “liquids are incompressible” as an exact statement, and then being surprised by water hammer or by thermal-expansion pressures in a closed circuit.
K = −dp/(dV/V); ΔV = −V Δp/K; c = √(Ks/ρ). Working values for water: K = 2.2 GPa, ρ = 1000 kg/m³, c = 1 483 m/s; official IAPWS R6-95 Table 7 check at 300 K: w = 1501.51914 m/s, Ks = 2.247 GPa. Cavitation where p ≤ pv(T); working pv ≈ 2.34 kPa at 20 °C (textbook, not an official table entry).
Summary
- The bulk modulus K = −dp/(dV/V) measures how little a fluid changes volume when the pressure changes. Liquids have K of the order of GPa; gases are much more compressible.
- A textbook working value for water is K = 2.2 GPa, giving c = 1 483 m/s with ρ = 1000 kg/m³ in a rigid container. An official IAPWS R6-95(2018) Table 7 point at 300 K gives w = 1501.51914 m/s and Ks = 2.247 GPa.
- Vapour pressure is the saturation pressure at the liquid temperature. A rounded textbook figure at 20 °C is 2.34 kPa. The official saturation formulation is IAPWS R6-95, with SR1-86 as a simpler companion.
- Cavitation occurs where the local absolute pressure falls to the vapour pressure. The same suction is more likely to cavitate as the liquid warms, because pv rises with temperature.
- The everyday picture that water boils at 100 °C and 101.325 kPa is a civil convention, not a claim of official IAPWS precision at exactly 100.000 °C.
Practice questions
Tap a question to see the answer.
1A rigid cylinder holds 0.50 m³ of water. The pressure rises by 2.2 MPa. Using K = 2.2 GPa, what is ΔV?
ΔV = −0.50 × 2.2×10⁶ / 2.2×10⁹ = −5.0×10⁻⁴ m³, or −0.50 L.
2Express the working bulk modulus 2.2 GPa in pascals.
2.2 × 10⁹ Pa.
3Using K = 2.2 GPa and ρ = 1000 kg/m³, what is c in a rigid container?
c = √(2.2×10⁹/1000) = 1 483 m/s.
4At the IAPWS R6-95(2018) Table 7 point T = 300 K, ρ = 996.5560 kg/m³, w = 1501.51914 m/s, what is Ks = ρ w², in GPa to three decimal places?
Ks = 996.5560 × (1501.51914)² = 2.247 GPa.
5A suction pressure of 12.0 kPa absolute is measured in water at 20 °C. Taking pv = 2.34 kPa, what is the margin, and is cavitation expected on this check?
Margin = 12.0 − 2.34 = 9.66 kPa. The pressure is above pv, so cavitation is not expected on this check.
6Why does a warmer liquid cavitate more readily at the same absolute suction pressure?
Because vapour pressure pv rises with temperature, so the margin p − pv becomes smaller and may disappear.
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- F. M. White, Fluid Mechanics, McGraw Hill, 8th edition, 2016.
- B. R. Munson, D. F. Young, T. H. Okiishi, W. W. Huebsch, Fundamentals of Fluid Mechanics, Wiley, 8th edition, 2016.
- IAPWS R6-95(2018), Revised Release on the IAPWS Formulation 1995, Table 7 verification point as used in the lesson. IAPWS SR1-86(1992), Revised Supplementary Release on Saturation Properties of Ordinary Water Substance.