3.1 Types of flow
After this lesson you should be able to:
- Classify a flow as steady or unsteady, and as uniform or non-uniform, from the definitions at a point and along a streamline.
- Compute the Reynolds number Re = ρ V D / μ = V D / ν and use it, with the conventional pipe values, to classify a pipe flow as laminar, transitional or turbulent.
- Distinguish laminar from turbulent motion, and recall the other ordinary kinematic labels (one-, two- or three-dimensional; rotational or irrotational; compressible or incompressible) without mixing them up.
Theory
Fluid kinematics describes the motion without asking, yet, what force produced it. The first task is to name the type of motion so that the right form of the continuity and momentum statements can be written later. The labels in this lesson are independent of one another: a flow can be steady and non-uniform, or unsteady and uniform, and so on.
Steady or unsteady. A flow is steady if, at every fixed point in the region of interest, the velocity and the other fluid properties do not change with time: ∂( )/∂t = 0 at a fixed point. It is unsteady if any of those quantities changes with time at a fixed point. A reservoir that is emptying, a filling pipeline, and a tide in an estuary are unsteady. A long pipeline running at a constant discharge, observed after start-up transients have died, is treated as steady. Steady does not mean “the fluid is at rest”; particles may be moving, but the picture at each point stays the same.
Uniform or non-uniform. A flow is uniform if, at a given instant, the velocity does not change with distance along the direction of the flow (for example along a straight prismatic pipe or canal of constant cross-section, running full). It is non-uniform if the velocity changes along the path — a tapering pipe, a river approaching a contracted bridge opening, or flow past a pier. Uniformity is a statement about change with distance, not about change with time. A tidal canal of constant section can be unsteady and still be spatially uniform at each instant.
One-, two- and three-dimensional. A description is one-dimensional if the velocity is treated as a function of a single streamwise coordinate (and of time, if the flow is unsteady): this is the usual civil model of flow in a pipe or a slender open channel, using a mean velocity V = Q/A on each section. A description is two-dimensional if variations in one direction (often the width) are neglected, as in a wide rectangular channel or a long spillway section. Most real flows are three-dimensional; the lower-dimensional models are engineering reductions.
Laminar or turbulent. In laminar motion, adjacent layers of fluid slide smoothly and mixing across the layers is at the molecular scale. In turbulent motion, the velocity at a point fluctuates irregularly and there is strong mixing across the stream. The usual dimensionless group that marks the difference in an internal flow is the Reynolds number, Re = ρ V L / μ = V L / ν, where V is a characteristic speed, L is a characteristic length (the internal diameter D of a circular pipe), ρ is the density, μ is the dynamic viscosity and ν = μ/ρ is the kinematic viscosity. For liquid water at 20 °C the examples use the civil working density ρ = 1 000 kg/m³, as in earlier lessons, and the ISO/IAPWS reference viscosity already used in Lesson 1.1: μ = 1.0016 mPa·s at 20 °C and p0 = 0.101325 MPa, so ν = μ/ρ = 1.0016 × 10⁻⁶ m²/s with that civil density.
Conventional pipe values. In a circular pipe, textbooks of fluid mechanics (White; Munson, Young, Okiishi and Huebsch, already listed for this subject) treat the motion as laminar when Re is below about 2 300, as turbulent when Re is above about 4 000, and as transitional in the band between. These figures are conventional working values, not official limits and not a property of the fluid alone: the actual onset of turbulence depends on the inlet, the wall roughness and the disturbances present. A careful experiment can keep pipe flow laminar to a much higher Reynolds number if the entry is quiet. The examples use the conventional values only as a classification aid, and they label them as such.
Other ordinary labels. A flow is incompressible, for civil purposes, if the density of a particle can be treated as constant; that is the usual model for liquid water in the lessons of this book, as discussed with the IAPWS equation of state in Lesson 1.2. Compressible flow matters when density changes are part of the problem (high-speed gas, water hammer treated with fluid elasticity). A flow is irrotational if the vorticity is zero (the water particle does not spin about its own axis); rotational if it is not. These labels are defined here and used in later kinematics lessons; they are not decided by the Reynolds number.
Derivation
- The Reynolds number is the ratio of a characteristic inertial stress ρ V² to a characteristic viscous stress μ V / L. Their quotient is ρ V L / μ, which is dimensionless. For a circular pipe the length is taken as the internal diameter D, and the speed as the mean velocity V = Q / A, with A = π D² / 4, so Re = ρ V D / μ = V D / ν. The same group appears when the Navier–Stokes equation is written in dimensionless form; only the interpretation is needed in this lesson.
- With the civil density ρ = 1 000 kg/m³ and the ISO/IAPWS reference viscosity μ = 1.0016 × 10⁻³ Pa·s, the kinematic viscosity used in the water examples is ν = μ/ρ = 1.0016 × 10⁻⁶ m²/s. If a different fluid is given, ρ and μ (or ν) must be the values stated for that fluid; the water reference is not to be reused for an oil or a gas.
- Steady means that a partial derivative with respect to time, taken at a fixed point, is zero. Uniform means that a derivative with respect to the streamwise coordinate, taken at a given instant, is zero. The two derivatives are independent, which is why all four combinations (steady uniform, steady non-uniform, unsteady uniform, unsteady non-uniform) occur in the field.
Steady at a point: ∂( )/∂t = 0. Unsteady: that derivative is not zeroUniform along the flow: no change of velocity with streamwise distance at a given instant. Non-uniform: the velocity changes along the pathMean velocity in a full pipe or a channel: V = Q / AReynolds number: Re = ρ V L / μ = V L / ν, with ν = μ / ρ. For a circular pipe, L = D (internal diameter)Civil water at 20 °C in the examples: ρ = 1 000 kg/m³, ISO/IAPWS μ = 1.0016 mPa·s at 20 °C and p0, so ν = 1.0016 × 10⁻⁶ m²/sConventional circular-pipe classification (textbook working values, not official limits): laminar if Re is below about 2 300; transitional between about 2 300 and about 4 000; turbulent if Re is above about 4 000
- Pipe examples use a circular cross-section running full, with V the mean velocity Q/A and L the internal diameter D.
- Water examples at 20 °C use the civil working density ρ = 1 000 kg/m³ and the ISO/IAPWS reference viscosity μ = 1.0016 mPa·s already used in Lesson 1.1. They do not use the CIPM maximum-density figure from that lesson, because the viscosity is quoted at 20 °C, not at the temperature of maximum density.
- The figures 2 300 and 4 000 are conventional textbook pipe values, used only to classify the computed Re. They are not treated as official limits.
- A one-dimensional description uses a single mean velocity on each section. Fluctuations in a turbulent flow are not resolved; only the mean V enters Re in this lesson.
- Incompressible labels follow Lesson 1.2: liquid water is treated as incompressible in ordinary civil problems.
Codes and standards
Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.
- The ISO/IAPWS reference viscosity of liquid water, μ = 1.0016 mPa·s at 20 °C and p0 = 0.101325 MPa, is the official value already used in Lesson 1.1. The civil working density in the examples is ρ = 1 000 kg/m³.
- There is no official Indian Standard, and no ISO clause cited here, that fixes a critical Reynolds number. The conventional pipe values of about 2 300 and about 4 000 are textbook working figures (White; Munson and co-authors), labelled as such.
- The definitions of steady, uniform, laminar and turbulent motion are continuum kinematics, as used in those same textbooks.
Worked examples
Problem. Water at 20 °C flows in a full circular pipe of internal diameter 50 mm at a mean velocity of 0.40 m/s. Use the civil density ρ = 1 000 kg/m³ and the ISO/IAPWS reference viscosity μ = 1.0016 mPa·s. Compute Re and classify the flow with the conventional pipe values.
- D = 0.050 m, V = 0.40 m/s, μ = 1.0016 × 10⁻³ Pa·s.
- Re = ρ V D / μ = (1 000 × 0.40 × 0.050) / (1.0016 × 10⁻³) = 20 / 0.0010016 = 19 968.
- By the conventional pipe values this is well above 4 000, so the flow is classified as turbulent.
- The same result is Re = V D / ν with ν = 1.0016 × 10⁻⁶ m²/s: 0.40 × 0.050 / 1.0016 × 10⁻⁶ = 19 968.
Answer. Re = 19 968, classified as turbulent (conventional pipe values).
Problem. The same 50 mm pipe carries water at 20 °C at a mean velocity of 0.040 m/s, at a constant discharge, in a long straight reach of constant diameter. Compute Re, classify it with the conventional pipe values, and say whether the flow is steady or unsteady, and uniform or non-uniform.
- Re = (1 000 × 0.040 × 0.050) / (1.0016 × 10⁻³) = 2 / 0.0010016 = 1 997.
- This is below the conventional figure of about 2 300, so the flow is classified as laminar.
- Because the discharge is constant, the velocity at a fixed point does not change with time: the flow is steady.
- Because the pipe is straight and of constant diameter and is running full, the mean velocity does not change along the reach: the flow is also uniform. It is therefore a steady, uniform, laminar pipe flow, under the conventional classification and the one-dimensional description V = Q/A.
Answer. Re = 1 997, classified as laminar (conventional pipe values). The flow is steady and uniform.
Step-by-step procedure
- Write down what is given: the fluid, the temperature (so that μ or ν can be taken from the right source), a characteristic speed and a characteristic length.
- For a full circular pipe take L = D and V = Q/A if a discharge is given rather than a velocity.
- Compute Re = ρ V D / μ, or V D / ν. For water at 20 °C in these examples, use ρ = 1 000 kg/m³ and μ = 1.0016 mPa·s (ν = 1.0016 × 10⁻⁶ m²/s). For any other fluid, use the values stated in the problem.
- Classify a circular-pipe result with the conventional figures (about 2 300 and about 4 000), and say that those figures are textbook working values, not official limits.
- Separately, classify the flow as steady or unsteady, and as uniform or non-uniform, from the definitions. Do not infer one pair from the other, and do not infer them from Re.
- If a later lesson needs a one-dimensional continuity or energy statement, the same mean velocity V = Q/A is the quantity that will be used.
Site notes
- A pipeline being filled, or a canal whose gate is being moved, is unsteady; a Reynolds number computed from a single instantaneous V still classifies the motion at that instant, but it does not make the flow steady.
- Approach flow to a bridge pier, a drop, or a sudden contraction is non-uniform even if the discharge is constant. The one-dimensional pipe formulae for Re still use a local D and a local V, but the flow is no longer uniform.
- Water at a temperature other than 20 °C does not have the ISO/IAPWS 20 °C viscosity. If the temperature is not 20 °C, μ must be taken from a stated value or from a later properties lesson; do not reuse 1.0016 mPa·s.
- Pump start-up, air in a main, and a partly full pipe all leave the assumptions of this lesson (full circular section, a single mean V). Those cases need a different model.
- Using a diameter in millimetres in Re = ρ V D / μ without converting to metres, which throws Re out by a factor of 1 000.
- Using μ in mPa·s without converting to Pa·s, or mixing μ and ν in the two forms of Re.
- Treating 2 300 or 4 000 as official limits, or as values that apply unchanged to a wide open channel, an air jet, or a sediment-laden river, without being given as such.
- Calling a constant-discharge flow in a tapering pipe “uniform”, or calling a tidal but prismatic canal “unsteady and therefore non-uniform”.
- Reusing the 20 °C water viscosity for a different fluid or a different temperature.
- Confusing laminar/turbulent (a Reynolds-number question) with rotational/irrotational or with compressible/incompressible.
Re = ρ V D / μ = V D / ν for a circular pipe, with V = Q/A. Water at 20 °C in the examples: ρ = 1 000 kg/m³, μ = 1.0016 mPa·s, ν = 1.0016 × 10⁻⁶ m²/s. Conventional pipe values (textbook, not official): laminar below about 2 300, turbulent above about 4 000. Steady means ∂/∂t = 0 at a point; uniform means no change along the path.
Summary
- Steady or unsteady is a statement about change with time at a point. Uniform or non-uniform is a statement about change with distance along the flow. The two are independent.
- The Reynolds number Re = ρ V L / μ = V L / ν compares inertia with viscosity. For a circular pipe, L is the internal diameter D and V is the mean velocity.
- For water at 20 °C the examples use ρ = 1 000 kg/m³ and the ISO/IAPWS reference viscosity μ = 1.0016 mPa·s. Conventional pipe classification uses about 2 300 and about 4 000 as textbook working values, not official limits.
- Laminar/turbulent, steady/unsteady, uniform/non-uniform, and the rotational and compressibility labels, answer different questions and should not be swapped.
Practice questions
Tap a question to see the answer.
1Water at 20 °C flows in a full 100 mm pipe at a mean velocity of 0.15 m/s. Using ρ = 1 000 kg/m³ and μ = 1.0016 mPa·s, compute Re and classify the flow with the conventional pipe values.
D = 0.100 m. Re = (1 000 × 0.15 × 0.100) / (1.0016 × 10⁻³) = 15 / 0.0010016 = 14 976. This is above about 4 000, so the flow is classified as turbulent (conventional textbook values).
2An oil of stated density 850 kg/m³ and stated dynamic viscosity 0.080 Pa·s flows in a 50 mm pipe at 0.60 m/s. Compute Re and classify it with the conventional pipe values.
Re = (850 × 0.60 × 0.050) / 0.080 = 25.5 / 0.080 = 318.75. This is well below about 2 300, so the flow is classified as laminar (conventional textbook values). The water viscosity is not used.
3A long prismatic canal of constant section carries a tide: the discharge at a section rises and falls with time, but at any one instant the discharge is the same at every section of the reach. Is the flow steady or unsteady? Uniform or non-uniform?
Unsteady, because the velocity at a fixed point changes with time. Uniform (at each instant), because there is no change along the prismatic reach at that instant. The two labels are independent.
4A reservoir feeds a tapering pipe at a constant discharge. Classify the flow in the pipe as steady or unsteady, and as uniform or non-uniform.
Steady, because the discharge is constant, so the velocity at each fixed section does not change with time. Non-uniform, because the area changes along the pipe, so the mean velocity V = Q/A changes along the path.
5Using μ = 1.0016 mPa·s and ρ = 1 000 kg/m³, find ν, then the Reynolds number in a 25 mm pipe carrying water at 20 °C at 0.10 m/s. Classify the result with the conventional pipe values.
ν = μ/ρ = 1.0016 × 10⁻³ / 1 000 = 1.0016 × 10⁻⁶ m²/s. Re = V D / ν = 0.10 × 0.025 / (1.0016 × 10⁻⁶) = 0.0025 / 1.0016 × 10⁻⁶ = 2 496. This lies between about 2 300 and about 4 000, so the flow is classified as transitional (conventional textbook values).
6A quiet laboratory pipe has Re = 8 000 and the dye filament remains smooth. Does this contradict the conventional value of about 4 000?
No. The figures 2 300 and 4 000 are conventional textbook working values for ordinary pipe entries, not official limits. A careful, quiet entry can keep the motion laminar to a much higher Reynolds number. The conventional classification would have called Re = 8 000 turbulent; the experiment shows that the actual transition depends on the disturbances present.
References
Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.
- F. M. White, Fluid Mechanics, McGraw Hill, 8th edition, 2016.
- B. R. Munson, D. F. Young, T. H. Okiishi, W. W. Huebsch, Fundamentals of Fluid Mechanics, Wiley, 8th edition, 2016.
- IAPWS / ISO reference viscosity of liquid water, μ = 1.0016 mPa·s at 20 °C and p0 = 0.101325 MPa, as already used in Lesson 1.1. The conventional circular-pipe Reynolds-number values of about 2 300 and about 4 000 are textbook working figures (White; Munson, Young, Okiishi and Huebsch), not official limits.