After this lesson you should be able to:

  • Define mass density, specific weight, specific gravity, dynamic viscosity, kinematic viscosity and surface tension, each with SI units.
  • Apply Newton’s law of viscosity to a linear velocity profile between parallel plates and compute shear stress and force.
  • Distinguish the precise reference properties of liquid water (CIPM/IAPWS density; ISO/IAPWS viscosity at 20 °C) from the civil-engineering convention ρ = 1000 kg/m³, γ = 9.81 kN/m³.
  • Compute capillary rise in a small tube from a stated surface tension, and list the assumptions in that formula.

Theory

A fluid is a material that cannot support a static shear stress: it deforms continuously so long as a shear stress acts. Liquids and gases are both fluids. In civil engineering the fluids of daily work are water, wastewater, air, and oils or bitumen in a few tests. This lesson deals with the properties that appear in almost every later calculation: density, specific weight, viscosity and surface tension.

Mass density ρ is mass per unit volume, ρ = m / V, in kg/m³. Specific weight (weight density) γ is weight per unit volume, γ = W / V = ρ g, in N/m³ or more often kN/m³. Specific gravity s (also called relative density) is the ratio of the density of the fluid to the density of a reference fluid, usually liquid water at a stated condition, so s is dimensionless. For ordinary water in civil calculations one takes s = 1 by choice of the reference.

Newton's law of viscosityU (moving)fixed platetτ = μ (U / t) for a linear profileIndiacon original, not to scale
Figure 1.1: Linear velocity profile between a moving plate and a fixed plate, illustrating Newton’s law of viscosity. Indiacon original, not to scale.

Liquid water has a density maximum at a temperature near 3.98 °C. The CIPM value adopted in the IAPWS guideline on fundamental constants (G5-01, revision of July 2026) is (999.974 95 ± 0.000 84) kg/m³ for VSMOW water at standard atmospheric pressure p0 = 0.101 325 MPa. That is a metrological reference, not a site number. In almost all civil engineering work, water is given the conventional density 1000 kg/m³, and with g = 9.81 m/s² this gives γw = 9.81 kN/m³. The two must not be mixed in one calculation without saying so. At 20 °C the density is a little below 1000 kg/m³ (about 998 kg/m³); if a problem states 998 kg/m³, use that value.

Viscosity is the fluid’s resistance to shearing. For a Newtonian fluid, the shear stress τ is proportional to the velocity gradient, τ = μ du/dy, where y is measured across the flow. The constant μ is the dynamic (or absolute) viscosity, in Pa·s (which is the same as N·s/m² or kg/(m·s)). Water, air, and most light oils are treated as Newtonian in ordinary civil problems. Non-Newtonian behaviour (muds, fresh concrete, some polymers) needs a different constitutive law and is not used in this lesson. The ISO/IAPWS reference value for the viscosity of liquid water at 20 °C and p0 is 1.0016 mPa·s, with an estimated uncertainty of 0.17 %. In rounded civil work this is often taken as 1.0 × 10⁻³ Pa·s.

Kinematic viscosity is ν = μ / ρ, in m²/s. It appears naturally in the Reynolds number, Re = V L / ν. A useful picture of Newton’s law is two parallel plates a small distance t apart, the gap filled with fluid, the lower plate fixed and the upper plate moving at a steady speed U. If the profile is linear, du/dy = U / t, so τ = μ U / t, and the force on a plate of area A is F = τ A. This is the arrangement used in Example 2. Real profiles between plates are linear only for a steadily moving plate and a Newtonian fluid, with no pressure-driven flow in the gap.

Surface tension σ is the tensile force per unit length in a liquid surface, in N/m. It matters in capillary tubes, small pores in soil, and some laboratory apparatus; it is usually negligible on the scale of a reservoir or a river. For a circular tube of diameter d, the capillary rise (or fall) of a liquid of density ρ is h = 4 σ cosθ / (ρ g d), where θ is the contact angle. For clean water on clean glass, θ is often taken as 0, so cosθ = 1. The practice question uses a stated working value σ = 0.0728 N/m, which is a rounded value near 20 °C, not a copied official table. Surface tension falls as temperature rises, and it is sensitive to contamination of the surface.

Pressure and temperature change all of these properties. Liquids are only slightly compressible (Lesson 1.2). Viscosity of liquids falls as temperature rises; viscosity of gases rises with temperature. Always state the temperature when a precise viscosity or density is used. The SI base units, including the kilogram, metre and second, follow the BIPM SI Brochure; g is taken as 9.81 m/s² in the examples unless a problem gives another value.

Derivation

  1. Density is defined as ρ = m / V. Weight is W = m g, so the specific weight is γ = W / V = ρ g.
  2. Specific gravity is s = ρ / ρ_ref. When ρ_ref is the conventional 1000 kg/m³ for water, s = ρ / 1000 kg/m³ and is dimensionless.
  3. For a Newtonian fluid the constitutive statement is τ = μ du/dy, with μ constant at a given temperature and pressure. Between parallel plates a distance t apart, with a linear profile from 0 to U, du/dy = U / t, hence τ = μ U / t and F = τ A = μ A U / t.
  4. Kinematic viscosity is defined by ν = μ / ρ, so that τ / ρ = ν du/dy. This combination appears when the Navier–Stokes or Reynolds-number form is written in terms of velocity alone.
  5. A circular capillary of diameter d has internal circumference π d. The vertical component of the surface-tension force is σ (π d) cosθ and balances the weight of the risen column, ρ g (π d² / 4) h, when the meniscus is at rest. Cancel π and rearrange to obtain h = 4 σ cosθ / (ρ g d).
Formulas, symbols and SI units
  • ρ = m / V (kg/m³)
  • γ = ρ g = W / V (N/m³ or kN/m³)
  • s = ρ / ρ_ref (dimensionless)
  • τ = μ du/dy (Pa); μ in Pa·s
  • ν = μ / ρ (m²/s)
  • For a linear gap profile: τ = μ U / t, F = μ A U / t
  • Capillary rise in a circular tube: h = 4 σ cosθ / (ρ g d) (m)
  • Reference values: CIPM/IAPWS maximum density of water (999.97495 ± 0.00084) kg/m³ near 3.98 °C; ISO/IAPWS μ = 1.0016 mPa·s at 20 °C and 0.101325 MPa. Examples use ρ = 1000 kg/m³ and g = 9.81 m/s² unless stated otherwise.
Assumptions and limits
  • Newton’s law with constant μ applies to Newtonian fluids only, at a stated temperature.
  • The parallel-plate formula τ = μ U / t assumes a linear velocity profile, steady motion, a uniform gap, and no additional pressure-driven flow.
  • The civil convention ρ = 1000 kg/m³, γ = 9.81 kN/m³ is used in the worked examples. It is not the same as the CIPM maximum-density value or the 20 °C density.
  • The capillary-rise formula assumes a circular tube, a static meniscus, uniform σ, and a stated contact angle (often θ = 0 for clean water on clean glass). Contamination and temperature change σ and θ.
  • g = 9.81 m/s² in the examples. Local gravity varies slightly over the Earth; that variation is ignored here.
  • Surface tension is neglected in large-scale open-channel and pipeline problems unless a problem asks for it.

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • BIPM, The International System of Units (SI Brochure), 9th edition, 2019 — units of mass, length, time and derived units for density and viscosity.
  • IAPWS G5-01 (2026 revision): CIPM maximum density of VSMOW water (999.97495 ± 0.00084) kg/m³ near 3.98 °C at p0 = 0.101325 MPa; ISO/IAPWS reference viscosity 1.0016 mPa·s at 20 °C and p0.
  • No Indian Standard is required for these definitions. IS 10500 (drinking water) and IS 3918 / current flow-measurement standards are not used in this lesson.
  • ISO 80000 (quantities and units) and ASTM viscosity-test methods are named for comparison only, not ranked.

Worked examples

Example 1 (illustrative): mass and weight of a volume of water

Problem. A tank holds 2.50 m³ of water. Taking the civil-engineering convention ρ = 1000 kg/m³ and g = 9.81 m/s², find the mass, the weight, and the specific weight. Say, in one sentence, how this density differs from the CIPM maximum-density value.

  1. Mass m = ρ V = 1000 × 2.50 = 2500 kg.
  2. Weight W = m g = 2500 × 9.81 = 24 525 N = 24.525 kN.
  3. Specific weight γ = ρ g = 1000 × 9.81 = 9810 N/m³ = 9.810 kN/m³. The same result is γ = W / V = 24.525 / 2.50 = 9.810 kN/m³.
  4. The conventional density 1000 kg/m³ is a rounded working value. The CIPM/IAPWS maximum density of water is 999.97495 kg/m³ near 3.98 °C, which would change the mass of this tank by only about 0.06 kg (2.50 × 0.025 = 0.063 kg) and is not used in ordinary civil calculations.

Answer. m = 2500 kg, W = 24.525 kN, γ = 9.810 kN/m³. The 1000 kg/m³ convention is a rounded working value, not the CIPM maximum-density figure.

Example 2 (illustrative): viscosity between parallel plates

Problem. An oil has dynamic viscosity μ = 0.30 Pa·s and density ρ = 880 kg/m³. It fills a 1.5 mm gap between a fixed plate and a parallel plate of area 0.50 m × 0.40 m that moves at 0.80 m/s. Assume a linear velocity profile. Find the kinematic viscosity, the shear stress in the oil, and the shear force on the moving plate.

  1. Kinematic viscosity ν = μ / ρ = 0.30 / 880 = 3.409 × 10⁻⁴ m²/s.
  2. Gap t = 1.5 mm = 0.0015 m. Velocity gradient du/dy = U / t = 0.80 / 0.0015 = 533.33 s⁻¹.
  3. Shear stress τ = μ du/dy = 0.30 × 533.33 = 160.0 Pa.
  4. Area A = 0.50 × 0.40 = 0.20 m².
  5. Force F = τ A = 160.0 × 0.20 = 32.0 N. Equivalently, F = μ A U / t = 0.30 × 0.20 × 0.80 / 0.0015 = 32.0 N.

Answer. ν = 3.409 × 10⁻⁴ m²/s, τ = 160.0 Pa, F = 32.0 N.

Step-by-step procedure

  1. Write the known quantities in SI units (convert mm to m, Pa·s if a value was given in cP or poise: 1 cP = 10⁻³ Pa·s).
  2. Decide which density is required: the civil convention 1000 kg/m³, a value stated in the problem, or a precise water-property value (CIPM or a stated temperature).
  3. For mass, weight and specific weight, use m = ρ V, W = m g and γ = ρ g.
  4. For a Newtonian gap problem, check that a linear profile is assumed, compute du/dy = U / t, then τ = μ du/dy and F = τ A.
  5. Compute ν = μ / ρ if the Reynolds number or kinematic viscosity is asked.
  6. For capillary rise, state σ, θ, ρ, g and d, then h = 4 σ cosθ / (ρ g d). Report the sign as a rise or a depression according to the contact angle.
  7. State units in the answer and the temperature or convention used for water properties.

Site notes

  • Water-supply and irrigation calculations almost always use γw = 9.81 kN/m³ (or sometimes 9.81 or 10 kN/m³ as a stated rounding). Do not switch mid-sheet.
  • Oil and bitumen viscosities depend strongly on temperature. A laboratory viscosity is useful only with the temperature at which it was measured.
  • Capillary rise can hold water in fine soil pores and in narrow cracks; it is not a useful model for flow in a large pipe.
  • A viscometer reading must be converted to Pa·s (or m²/s) before it is used in Newton’s law or a Reynolds number.
  • Wind and air-flow problems need the density of air, which is about 1.2 kg/m³ at ordinary temperature and pressure — three orders of magnitude below water. Do not use 1000 kg/m³ for air.
Common mistakes
  • Using γ = 9.81 kN/m³ as if it were a density in kg/m³, or treating 1000 kg/m³ as 1000 kN/m³.
  • Forgetting to convert a gap from millimetres to metres before computing U / t.
  • Using μ in the Reynolds number instead of ν, or the reverse.
  • Applying τ = μ U / t when the velocity profile is not linear, or when the fluid is not Newtonian.
  • Taking water viscosity as 1 Pa·s instead of about 10⁻³ Pa·s (off by a thousand).
  • Ignoring the contact angle, or using a surface tension from one temperature with a density from another, in a precise capillary calculation.
  • Mixing the CIPM maximum-density value with the 1000 kg/m³ convention in the same arithmetic without a reason.
Quick check

ρ = m/V, γ = ρg. Newtonian: τ = μ du/dy; in a linear gap, τ = μU/t. ν = μ/ρ. Civil water: ρ = 1000 kg/m³, γ = 9.81 kN/m³, unless a precise CIPM/IAPWS or stated value is required. 1 cP = 10⁻³ Pa·s.

Summary

  • Density ρ is mass per volume; specific weight γ = ρ g; specific gravity is a ratio of densities.
  • The CIPM/IAPWS maximum density of water is 999.97495 kg/m³ near 3.98 °C; civil calculations conventionally use 1000 kg/m³ and γw = 9.81 kN/m³.
  • For a Newtonian fluid, τ = μ du/dy. Kinematic viscosity is ν = μ/ρ. The ISO/IAPWS reference viscosity of water at 20 °C is 1.0016 mPa·s.
  • Between parallel plates with a linear profile, τ = μ U/t and F = τ A.
  • Surface tension matters in small tubes and pores: h = 4σ cosθ / (ρ g d). It is usually negligible at large civil scales.

Practice questions

Tap a question to see the answer.

1Express 2.0 cP in Pa·s.

2.0 cP = 2.0 × 10⁻³ Pa·s.

2An oil has μ = 0.080 Pa·s and ρ = 860 kg/m³. What is ν?

ν = 0.080/860 = 9.302 × 10⁻⁵ m²/s.

3Water in a 1.20 m³ tank, using ρ = 1000 kg/m³. What is the mass?

m = 1000 × 1.20 = 1200 kg.

4What is the ISO/IAPWS reference dynamic viscosity of liquid water at 20 °C and standard atmospheric pressure?

1.0016 mPa·s, with an estimated uncertainty of 0.17 %.

5A plate of area 0.10 m² moves at 0.50 m/s at 2.0 mm from a fixed plate. The fluid has μ = 0.20 Pa·s and the profile is linear. What is the shear force?

t = 0.0020 m; F = μ A U / t = 0.20 × 0.10 × 0.50 / 0.0020 = 5.0 N.

6Find the capillary rise of water in a clean glass tube of diameter 0.50 mm. Take σ = 0.0728 N/m, θ = 0, ρ = 998 kg/m³ and g = 9.81 m/s².

h = 4 × 0.0728 / (998 × 9.81 × 0.00050) = 0.2912 / 4.89519 = 0.0595 m, or 59.5 mm.

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • F. M. White, Fluid Mechanics, McGraw Hill, 8th edition, 2016.
  • B. R. Munson, D. F. Young, T. H. Okiishi, W. W. Huebsch, Fundamentals of Fluid Mechanics, Wiley, 8th edition, 2016.
  • IAPWS, Guideline on the Use of Fundamental Physical Constants and Basic Constants of Water, G5-01, revision of July 2026.
  • BIPM, The International System of Units (SI Brochure), 9th edition, 2019.
Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.

Sent privately to the Indiacon editor; not published.