Indiacon CivilSubscribe

Textbook › Engineering Mechanics › Chapter 4 › Lesson 4.5

4.5 Resultants of distributed loads

Engineering Mechanics Chapter 4: Centroid and centre of gravity Under review — not yet three-checked Author: Indiacon

Learning objectives

After this lesson you should be able to:

  • Replace a distributed load by a single resultant equal to the area of the load diagram acting through its centroid.
  • Find resultants of uniform, triangular, trapezoidal and general distributed loads, and of hydrostatic pressure on a wall.
  • Build line loads on beams from slab and member self-weight using code unit weights.

Theory

Many loads on structures are spread out rather than concentrated: the self-weight of a beam, a floor finish, soil or water pressing on a wall, wind on a cladding panel. A distributed load is described by its intensity w(x), a force per unit length (kN/m) for a line load or a force per unit area (kN/m²) for a surface load. The load diagram is a plot of w against position.

For the equilibrium of the whole body, the distributed load can be replaced by one force. Its size equals the total load, which is the area under the load diagram, and its line of action passes through the centroid of that area. A uniform load w over length L becomes wL at mid-length. A triangular load rising from zero to w becomes wL/2 at two thirds of the length from the zero end, the centroid of a triangle. A trapezium is split into a rectangle and a triangle.

w1w2R = (w1 + w2) L / 2x̄ from the w1 endR = area, through the centroidIndiacon original, not to scale
Figure 4.5: A trapezoidal line load replaced by its resultant: the area of the load diagram acting through its centroid. Indiacon original, not to scale.

Water pressure on a vertical wall rises linearly with depth, p = γw h, where γw is the unit weight of water (about 9.81 kN/m³). The pressure diagram on a wall of water depth H is a triangle, so the resultant per metre run is γw H²/2 acting H/3 above the base. The same reasoning is used for earth pressure on retaining walls in the soil mechanics chapters.

The resultant is valid only for the equilibrium of the body as a whole, for example to find support reactions. It must not be used to find internal shear force and bending moment inside the loaded length: for that, cut the beam and replace only the part of the load on one side of the cut by its own resultant.

Derivation

  1. Consider a line load of intensity w(x) on a beam from x = 0 to L. An element dx carries a force dF = w dx.
  2. The total force is R = ∫₀ᴸ w dx, which is the area under the load diagram.
  3. The moment of the distributed load about x = 0 is ∫₀ᴸ x w dx. For the single force R at x̄ to be equivalent, R x̄ = ∫ x w dx.
  4. So x̄ = ∫ x w dx / ∫ w dx, which is the x-coordinate of the centroid of the load diagram area.
  5. Uniform load: R = wL, x̄ = L/2. Triangular load w = w0 x/L: R = w0 L/2, x̄ = ∫ w0 x²/L dx / R = (w0 L²/3)/(w0 L/2) = 2L/3 from the zero end.
  6. Hydrostatic pressure on a vertical wall: p = γw y at depth y. Per metre run, R = ∫₀ᴴ γw y dy = γw H²/2, acting at depth ∫ γw y² dy / R = 2H/3, which is H/3 above the base.
Formulas, symbols and SI units
  • R = ∫ w dx (kN, with w in kN/m and x in m)
  • x̄ = ∫ x w dx / ∫ w dx
  • Uniform load: R = wL at L/2
  • Triangular load (0 to w): R = wL/2 at 2L/3 from the zero end (L/3 from the peak)
  • Trapezoid (w1 to w2): R = (w1 + w2) L/2 at x̄ = L (w1 + 2w2) / [3 (w1 + w2)] from the w1 end
  • Hydrostatic: p = γw h (kN/m²); R = γw H²/2 per metre at H/3 above the base
  • Slab self-weight per unit area = unit weight × thickness (kN/m²); line load = area load × tributary width (kN/m)
Assumptions and limits
  • The body is rigid for the purpose of the resultant; loads do not move as the structure deflects.
  • Load intensity is known as a function of position; on real floors it is idealised as uniform over each panel.
  • The resultant replaces the load only for external equilibrium of the part considered.
  • Hydrostatic results assume still water of constant unit weight.

Codes and standards

Indian Standards are cited by number and clause only; no clause text, tables or figures are reproduced. Other standards are listed for comparison, not ranked.

  • IS 456:2000, clause 19.2 and 19.2.1: dead loads are calculated from unit weights of the materials specified; the unit weights of IS 875 (Part 1) may be used, and unless more accurate calculation is warranted, plain and reinforced concrete made with sand and gravel or crushed natural stone aggregate may be taken as 24 kN/m³ and 25 kN/m³ respectively.
  • IS 875 (Part 1):1987, Dead loads: unit weights of building materials and stored materials (Table 1) and of building parts and components (Table 2), used to build distributed dead loads.
  • IS 875 (Part 2):1987, Imposed loads: the source for floor and roof imposed loads, as directed by IS 456:2000 clause 19.3.
  • For comparison, EN 1991-1-1:2002, Annex A, Table A.1 gives a nominal density of 24 kN/m³ for normal-weight concrete, increased by 1 kN/m³ for a normal percentage of reinforcing and prestressing steel.

Worked examples

Example 1 (exam style)

Problem. A simply supported beam AB of span 6 m carries a load that varies linearly from 10 kN/m at A to 20 kN/m at B. Find the resultant, its position from A and the support reactions.

  1. Split the trapezium into a uniform 10 kN/m (resultant 60 kN at 3 m) and a triangle rising from 0 to 10 kN/m (resultant 30 kN at 2/3 × 6 = 4 m from A).
  2. R = 60 + 30 = 90 kN; x̄ = (60 × 3 + 30 × 4)/90 = 300/90 = 3.333 m from A.
  3. Check with the trapezium formula: x̄ = 6 (10 + 40)/(3 × 30) = 3.333 m.
  4. Moments about A: RB × 6 = 90 × 3.333, so RB = 50 kN; RA = 90 − 50 = 40 kN.

Answer. R = 90 kN at 3.333 m from A; RA = 40 kN, RB = 50 kN

Example 2 (site style)

Problem. A reinforced concrete slab 150 mm thick spans onto a beam with a tributary width of 3 m. The beam is 300 mm wide and 450 mm deep overall and spans 5 m, simply supported. Using 25 kN/m³ for reinforced concrete, find the dead-load line load on the beam from slab and beam self-weight, its resultant and the reactions.

  1. Slab self-weight = 25 × 0.150 = 3.75 kN/m²; on 3 m width, 3.75 × 3 = 11.25 kN/m.
  2. Beam self-weight = 25 × 0.300 × 0.450 = 3.375 kN/m (ignoring the small overlap with the slab, which is conservative).
  3. Total w = 14.625 kN/m. Resultant R = 14.625 × 5 = 73.13 kN at mid-span.
  4. By symmetry each reaction is 36.56 kN. Floor finish and imposed load are added in the same way from their own intensities.

Answer. w = 14.625 kN/m; R = 73.13 kN; reactions 36.56 kN each

Example 3 (water pressure)

Problem. Water stands 3 m deep against a vertical wall. Find the pressure at the base, the resultant force per metre run and its height above the base. Take γw = 9.81 kN/m³.

  1. Base pressure p = 9.81 × 3 = 29.43 kN/m².
  2. Resultant = ½ × 29.43 × 3 = 44.15 kN per metre run.
  3. It acts through the centroid of the triangle, H/3 = 1.0 m above the base.
  4. Overturning moment about the base per metre = 44.15 × 1.0 = 44.15 kN·m.

Answer. 44.15 kN/m acting 1.0 m above the base

Step-by-step procedure

  1. Draw the load diagram along the member with intensities at key points.
  2. Split it into rectangles, triangles or other shapes with known centroids, or set up ∫ w dx if w(x) is a function.
  3. Find the resultant of each part (area) and its position (centroid).
  4. Combine for the total resultant and its position, or use the parts directly in the equilibrium equations.
  5. For internal forces, cut the member first and take the resultant of only the load on one side.

Site notes

  • Build dead loads layer by layer: structural slab, screed, floor finish, ceiling and services, each as thickness × unit weight; the code unit weights are for design, and actual weights of special finishes come from the supplier.
  • Temporary loads such as stacked bricks, cement bags or rebar bundles on a fresh slab are concentrated and heavy; spread them, and check them against the propping design.
  • Water retained during tank testing gives a triangular pressure on the walls; fill in stages as specified so that cracks and leaks can be inspected before full head.
Common mistakes
  • Placing the resultant of a triangular load at mid-length instead of at the centroid.
  • Measuring the 2L/3 position from the peak instead of from the zero end.
  • Using the total resultant to find bending moment at a section inside the loaded length.
  • Mixing kN/m² and kN/m: an area load must be multiplied by a tributary width to become a line load.
  • Using 25 kN/m³ for unreinforced concrete or ignoring the beam self-weight.
Quick check

The resultant of any linearly varying load lies between L/3 and L/2 from the heavier end: L/2 for uniform load, L/3 for a triangle.

Summary

  • A distributed load equals its area and acts through its centroid.
  • Uniform: wL at L/2; triangle: wL/2 at L/3 from the peak; trapezium: split.
  • Hydrostatic: γw H²/2 per metre at H/3 above the base.
  • Use the resultant for reactions, not for internal forces inside the loaded length.

Practice questions

Tap a question to see the answer.

1A load varies from 0 to 12 kN/m over 4 m. Find the resultant and its position from the zero end.

R = 12 × 4 / 2 = 24 kN at 2/3 × 4 = 2.667 m.

2A 3 m cantilever carries 8 kN/m uniformly. Find the resultant and the fixed-end moment.

R = 24 kN at 1.5 m; M = 24 × 1.5 = 36 kN·m.

3Water stands 2.5 m deep against a wall. Find the force per metre and its height above the base.

R = ½ × 9.81 × 2.5² = 30.66 kN/m at 2.5/3 = 0.833 m above the base.

4A beam carries w(x) = 6x² kN/m from x = 0 to 2 m. Find the resultant and its position.

R = ∫ 6x² dx = 16 kN; x̄ = ∫ 6x³ dx / 16 = 24/16 = 1.5 m.

5Find the self-weight per square metre of a plain concrete slab 100 mm thick with crushed stone aggregate.

24 × 0.100 = 2.4 kN/m².

6Why may the total resultant not be used to find the bending moment at mid-span of a uniformly loaded beam?

Because the bending moment at a section depends only on the loads on one side of the cut; the resultant of the whole load acts at mid-span and has no lever arm about it, which would wrongly give zero load moment.

References

Standard texts, listed in no order of merit. Our explanations, examples and diagrams are original; nothing is copied from these books.

  • F. P. Beer, E. R. Johnston, D. F. Mazurek, P. J. Cornwell, B. P. Self, Vector Mechanics for Engineers: Statics and Dynamics, McGraw Hill, 12th edition, 2019.
  • R. C. Hibbeler, Engineering Mechanics: Statics, Pearson, 15th edition, 2022 (published 2021).
  • J. L. Meriam, L. G. Kraige, J. N. Bolton, Engineering Mechanics: Statics, Wiley, 9th edition, 2018.
  • S. Timoshenko, D. H. Young, J. V. Rao, S. Pati, Engineering Mechanics (in SI units), McGraw Hill Education (India), 5th edition, 2013.
Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.

Sent privately to the Indiacon editor; not published.