Indiacon CivilSubscribe

Home › Construction methods › Lesson 18.1

18.1 Articulated concrete block mattress (ACBM)

Construction methods Chapter 18: River and coastal protection Checked 13 Nov 2026 Author: Indiacon

Learning objectives
  • Explain what an articulated concrete block mattress is and why flexibility matters against scour.
  • Name the components (blocks, connection, filter, drainage layer, terminations, toe) and the generic system types.
  • Describe the conceptual design checks: block stability, filter, toe or launching apron, extent and edge anchorage.
  • Plan the construction sequence and the site QC checks.
  • Compare ACBM with riprap and gabion mattresses in neutral terms.

Overview

An articulated concrete block mattress (ACBM) is a flexible revetment made of precast concrete blocks linked together into a continuous mat and laid over a filter on a river bank, channel bed or launching apron. The word articulated means each block can rotate a little relative to its neighbours, so the mat follows the ground as it settles or as scour lowers the bed at the toe.

It belongs to the same family as stone pitching, boulder or riprap revetment, gabion and wire-mesh mattresses and geobag aprons: all of them protect an erodible bank by putting a heavy, permeable armour layer over a filter. ACBM differs in that the armour is made of uniform factory-made units, so the weight per square metre and the joint pattern are controlled, and in that the units are linked, so a single block is less likely to be lost.

The term is generic. Several manufacturers make block mats with different shapes and connections; this lesson uses only generic descriptions from public guidance (IS 14262, the CWC handbook and FHWA HEC-23) and names no product. Indian revetment guidance (IS 14262) was written mainly for stone, crates and concrete blocks; its toe, filter and anchorage logic applies to block mats, while the block stability itself must come from the tested data of the system used.

Components of an ACBM

  • Block: precast concrete unit, dense and durable. HEC-23 refers to ASTM D6684 for minimum strength, absorption and density of ACB concrete; Indian projects follow the contract specification and IS concrete standards for the blocks themselves.
  • Connection: cables, ropes, interlock, or a bonded geotextile or geogrid (see Types).
  • Filter: geotextile, granular, or both, under the whole mat. It keeps bank soil in place while letting water out. HEC-23 treats the filter (and any drainage layer) as part of the ACB system, not an optional extra.
  • Drainage layer (where the tested system used one): coarse uniform granular layer or a synthetic drainage net between blocks and filter; HEC-23 says that if the test included it, the design must include it.
  • Top termination: mat and filter turned into an anchor trench above the design water level plus freeboard (IS 14262 cl. 6.1; HEC-23 8.3.4).
  • Upstream and downstream end keys: mat edges trenched or tied into the adjoining bank so flow cannot get behind them (IS 14262 cl. 6.1).
  • Toe: toe-down trench to the design scour level, or a flexible launching apron laid at low water level that drapes into the scour hole (IS 14262 cl. 5; CWC 2012 sec. 4.9.3).

Types of ACBM systems

Different suppliers make ACBM in different forms, but the forms fall into a few generic families that differ in how the blocks are held together, whether the cells are open, and how the mat is placed. FHWA HEC-23 (3rd ed., Design Guideline 8, section 8.1) describes the family in these same generic terms: interlocking and non-interlocking blocks, cabled and non-cabled systems, vegetated and non-vegetated systems, and open-cell and closed-cell blocks, joined by interlock and/or cables, ropes, geotextiles or geogrids. The descriptions below are Indiacon summaries by working principle only; no product is named, compared or recommended.

Type (generic)How it holds togetherTypical usesKey design pointKey QC point
A. Cable- or rope-tied block matBlocks threaded on longitudinal (often also transverse) cables or synthetic ropes, usually assembled into mats off siteLarge bank revetments, launching aprons, under-water placement, bridge pier and abutment apronsStability comes from the tested block-on-subgrade behaviour; HEC-23 ignores cable restraint in the factor of safety because cables do not stop loss of contact with the subgradeCable or rope type, corrosion or UV resistance, end fittings and splices between adjacent mats; no slack loops that let blocks lift
B. Interlocking blocks, no cablesShape of each block (lugs, keys or offsets) locks it to its neighboursBank and channel lining above water, embankment slopes, overtopping protection where placement can be checked by eyeInterlock and block weight resist lift; performance must come from the system’s own hydraulic test dataTight, even joints and no protruding blocks; HEC-23 shows that a block standing proud attracts extra lift and drag
C. Blocks cast onto or bonded to a geotextile or geogridBacking fabric or grid connects the blocks and forms part of the matRevetments where a continuous connection and quick mat placement are wantedThe backing must also act as, or sit on, a correct filter; its strength must suit lifting and installation stressesBond of blocks to backing, no tears at lifting points, overlaps and edge trenches as designed
D1. Open-cell blocks (vegetated or gravel-filled)Any of A to C, with voids through each blockLow to moderate velocity banks where green cover and drainage are wantedOpen cells relieve uplift but expose the filter; a granular filter must be coarser than half the smallest cell opening (HEC-23 8.3.5)Cell fill and topsoil placed as specified; vegetation established before the design flood season where possible
D2. Closed-cell (solid) blocks, plainAny of A to C, solid unitsHigher-velocity or permanently submerged zones, apronsMore weight per unit area for the same size; drainage relies on joints and any drainage layerJoint width and drainage layer as tested; no fines washing out at joints
Placement: prefabricated mats by craneMats lifted with a spreader bar; geotextile may be attached to the mat underside for under-water work (HEC-23 8.4.5)Long reaches, under water, launching apronsMat panel size suits crane reach and lift capacity; seams fall where designedOverlap of adjacent mats, seam ties, geotextile not torn or folded
Placement: block by block by handUnits set individually on the prepared filterSmall or dry-work areas, repairs, tight geometryOnly where the subgrade can be shaped and inspected in the dryLine and level, joint spacing, protrusion limit checked block by block

Whatever the type, follow the manufacturer’s tested design data (hydraulic performance test results such as those obtained by the ASTM D7277 procedure named in HEC-23) for the specific system being used. Values from one system must never be applied to another, because block shape, weight, connection and drainage layer all change the result.

How it works

Flowing water erodes a bank in two ways: it drags and lifts surface particles, and it pulls fine soil out through any gap (piping and suction). A revetment answers both. Weight on the surface resists drag and lift, and a filter stops soil escaping while letting water pass so that pore pressure cannot build up behind the cover.

An ACBM does this with many small heavy units that are linked but free to rotate. Because the mat is flexible, it follows small settlements and the edge of a scour hole instead of bridging over them; a rigid slab in the same place would crack or be undermined and left hanging. HEC-23 defines ACB failure as local loss of intimate contact between the mat and the subgrade, because once contact is lost, flow gets under the blocks, uplift grows, soil washes out and blocks are removed. Every design and site check below aims to keep that contact.

Linking does not add hydraulic stability by itself in the HEC-23 method: the benefit of cables is already inside the tested performance of the block, and cables mainly stop blocks being lost once something has gone wrong. That is why subgrade preparation, the filter and the edge details matter more than the cable.

Derivations and design logic

Derivation 1, protection layer against negative head (IS 14262 cl. 3.5, loose layer). Flow at velocity V over the cover can reduce pressure on top of it by about one velocity head, Δp ≈ ρV²/2. A layer of thickness T and specific gravity Ss weighs (Ss − 1)ρgT per unit area when submerged. Setting (Ss − 1)ρgT ≥ ρV²/2 and cancelling ρ gives T ≥ V²/[2g(Ss − 1)], the IS form. Example: V = 3 m/s, Ss = 2.4 gives T = 9/(2 × 9.81 × 1.4) = 0.328 m of solid concrete equivalent. ACB systems are not sized this way; their tested performance (drainage layer, interlock, contact) governs, but the relation shows why weight per unit area and drainage control uplift.

Derivation 2, block factor of safety (HEC-23 DG8, concept only). Take moments about the downstream corner of one block resting on the slope. Restraining moment = submerged weight component into the slope × its lever arm. Overturning moment = weight component down the slope + drag + lift, each × its lever arm, plus extra drag and lift on a block that protrudes. FS = restraining moments / overturning moments; HEC-23 uses a minimum of about 1.2 for bank revetment with well-known hydraulics, higher at bends, abutments and piers, and 1.5 minimum at bridge piers. The equation and its coefficients are in the circular and must be used with the specific system’s test data; they are not reproduced here.

Derivation 3, why a loose apron is about 1.5 times wider and 1.5 times thicker (Indiacon observation, consistent with CWC 2012 sec. 4.9.4). A loose apron of width W and thickness 1.5t that launches down a 2H:1V scour face of depth D must cover a slope length D√5 ≈ 2.24D at thickness t. Volume balance: 1.5t × W = t × 2.24D, so W ≈ 1.49D, which is the 1.5D width rule. A linked mat cannot thicken and spread like loose stone, so an ACBM apron is detailed by length: it must reach the full launched slope length plus anchorage.

Assumptions and limits

  • Bank slope is first made geotechnically stable; IS 14262 cl. 3.3 recommends 2H:1V or flatter for normal bank protection and a slip-circle check for important works. A revetment does not fix a deep slip.
  • Design velocity and scour depth come from a hydraulic study for the design flood (CWC 2012 suggests a 50-year return period for pitching unless damage potential justifies more).
  • Lacey-type scour formulas are empirical and suit alluvial sand beds; they do not apply to rock, coarse gravel or cohesive beds without judgement.
  • The HEC-23 method assumes the hydraulic test data of the exact system; it stops being valid if the block, connection or drainage layer differs from the tested set-up.
  • Limits: very steep slopes, ice or debris impact, wave attack on coasts (needs coastal design methods) and supercritical flow need specialist checks.

Codes and guidance side by side

SourceWhat it covers for ACBM (paraphrased)
IS 14262:1995 (BIS) Planning and design of revetments – GuidelinesBank slope (cl. 3.3), layer thickness against negative head (cl. 3.5), filter including geotextile criteria in Annex A (cl. 3.7), toe key, toe wall, sheet pile or launching apron and scour depth (cl. 5.1–5.7), end and top anchorage (cl. 6.1). Written for stone, crates and concrete blocks; ACBM design uses its toe, filter and anchoring logic.
CWC (Flood Management Organisation) handbook on flood protection, anti-erosion and river training works, 2012Indian field practice for revetments, toe protection and launching aprons laid at low water level, apron width and thickness relations, anchoring (sec. 4.9–4.10).
FHWA HEC-23, 3rd ed., Vol. 2 (FHWA-NHI-09-112, 2009), Design Guideline 8ACB systems for bank revetment and bed armour and for pier scour protection: failure definition, factor-of-safety method, target safety factor selection, layout, terminations and filter requirements.
ASTM D7277 / ASTM D6684 (named in HEC-23)Hydraulic performance test method and material specification for ACB systems (named only; texts not used here).

Standards are listed side by side and are not ranked. Use the edition named in the contract.

Quick checks

  • Toe-down or apron must reach below the design scour level; if the drawing shows the mat ending at today’s bed level, ask for the scour calculation.
  • Upstream coverage at least one channel width and downstream at least 1.5 channel widths beyond the attacked reach is the HEC-23 starting point for longitudinal extent (straight reaches; bends need more study).
  • Freeboard above design water level: HEC-23 suggests about 0.3–0.6 m for open reaches and 0.6–0.9 m for constricted reaches (1–2 ft and 2–3 ft); IS 14262 cl. 6.1 asks for adequate freeboard where the top is above HFL. Use the project value.
  • Slope of blocks at piers no steeper than 1V:2H (HEC-23 Fig. 8.10 note); on banks, 2H:1V or flatter unless the tested system and a stability check allow steeper.

Method step by step

ACBM bank revetment: cross-sectionHFLLWLapron after scour (drapesdown slope, about 2H:1V)flow (out of page)top anchor trenchbank top (above HFL)bank slope 2H:1Vgeotextile filterblock mattresslaunching apron at LWLsubgrade (bank soil)Indiacon original, not to scale
Figure 18.1a: Cross-section of an ACBM bank revetment: bank slope, geotextile filter, block mattress, top anchor trench, launching apron at low water level, water levels and flow direction. Indiacon original, not to scale.
  1. Collect data: cross-sections, bank soil grading and strength, design discharge, high flood level (HFL) and low water level (LWL), velocity, history of erosion (IS 14262 and CWC 2012 list these).
  2. Fix the design flood, design velocity and scour depth; compute the toe-down depth or launching apron length.
  3. Check overall bank stability; trim the slope to 2H:1V or flatter unless a stability check allows otherwise, and remove debris, roots, cobbles and soft pockets (HEC-23 warns against placing blocks on rubble or cobbles).
  4. Excavate the top anchor trench, the upstream and downstream end keys and the toe-down trench (or prepare the apron bed at LWL).
  5. Place the filter: geotextile with the specified overlaps, laid loose without wrinkles and pinned, or a granular filter of the specified thickness; on a sand cushion where specified.
  6. Place the drainage layer if the tested system used one.
  7. Lay the mats by crane and spreader bar from the top down (or blocks by hand in the dry), in the sequence and with the overlap direction given in the system detail and drawings.
  8. Connect adjacent mats (cable splices, ties or interlock) as per the system detail; check no block protrudes beyond the allowed tolerance.
  9. Backfill and compact the anchor and end trenches; fill open cells with the specified gravel or topsoil and seed where vegetated.
  10. Survey the finished surface and record as-built levels; inspect after every major flood and repair displaced or undermined areas promptly.
Generic ACBM types (plan)A Cable/rope-tiedB Interlocking,no cablesC Bonded/cast ontogeotextile or geogridD Open-cell (top,vegetated) / closed-cell (bottom, plain)Placement: A and C usually as prefabricated mats lifted by cranewith a spreader bar; B and some open-cell units often laid block by block.Generic shapes only; no product geometry. Indiacon original, not to scale
Figure 18.1b: Plan sketches of the generic ACBM types: cable-tied, interlocking, bonded to a backing, open-cell versus closed-cell. Indiacon original, not to scale.

Where used and limits

  • River bank revetment on eroding reaches and the outer banks of bends.
  • Launching aprons at the toe of revetments, guide banks and spurs, laid at low water level so they drape into scour holes.
  • Bridge pier and abutment scour protection (HEC-23 Design Guideline 8, Application 2: mat extending at least twice the pier width all round, toed down to the design scour depth, filter sealed to the pier).
  • Channel bed armour, culvert outlets, canal linings, embankment slopes and overtopping protection where tested for that use.
  • Coastal and lake shores only with a wave-attack design; current-based methods do not cover breaking waves.
  • Limits: needs a stable slope and a well-prepared subgrade; unsuitable where large debris or boulders hit the mat repeatedly; tested hydraulic limits of the specific system must not be exceeded.

Equipment (generic)

  • Excavator or long-reach excavator for trimming, trenches and toe-down.
  • Crane with a spreader bar for prefabricated mats; floating crane or pontoon for under-water placement.
  • Survey instruments (level, total station or GNSS; echo sounder for under-water profiles).
  • Plate compactor for trench backfill; hand tools for block-by-block placement.
  • Geotextile cutting and pinning tools; cable splicing or tie tools as per the system detail. Equipment is named by function only.
QA/QC checks on site

Clauses are paraphrased and cited by number only.

  • Bank profile surveyed before filter placement; slope and surface smoothness within tolerance; no cobbles, roots or voids (HEC-23 8.3.3).
  • Geotextile matches the specification and the IS 14262 Annex A opening-size criteria for the bank soil; overlaps, pins and no tears; under-water geotextile fixed to the mat underside before lifting (HEC-23 8.4.5).
  • Granular filter, if used, at least 4 × d50 or 150 mm, whichever is more, increased by 50 % under water, and d50 larger than half the smallest cell opening (HEC-23 8.3.5).
  • Block delivery checked for dimensions, cracks and strength records against the specification.
  • Mat joints and connections as per the system detail; protruding blocks reset.
  • Top trench, end keys and toe-down depth measured against the drawing; launching apron length and level at LWL recorded (IS 14262 cl. 5–6; CWC 2012 4.9.3).
  • As-built survey and photo record; post-flood inspection and repair register.
Safe site practice
  • Work near and on water: life jackets, rescue boat and throw lines; no lone working at the waterline.
  • Crane lifts of mats: lifting plan, rated spreader bar, exclusion zone, tag lines; no one under a suspended mat.
  • Excavation of toe trenches in saturated soil: keep plant back from the edge, watch for slumping, follow the rising river level.
  • Monitor weather and upstream flow warnings; stop work in rising flood conditions.
  • This lesson is educational and is not a method statement; follow the approved site-specific plan and statutory rules.
Common mistakes
  • Ending the mat at the present bed level with no toe-down or apron, so the first flood scours under the toe and the mat hangs or rolls up.
  • Laying blocks on an uneven slope with cobbles or loose fill, so blocks protrude and lose contact; HEC-23 notes a protruding block sharply reduces the factor of safety.
  • Wrong or torn geotextile: too fine an opening that clogs and builds uplift, or too coarse an opening that lets soil wash out.
  • Leaving the upstream edge without an end key, so flow gets behind the mat.
  • Using another system’s tested values, or omitting the drainage layer that the tested system relied on.
  • Treating the cables as the source of stability and skipping subgrade and filter checks.
  • Using a current-based design for a wave-exposed shore.

Comparison with other revetments

Neutral comparison of generic methods; none is ranked. Choice depends on site hydraulics, materials, access, cost and maintenance.

AspectACBMRiprap (loose stone)Gabion / wire-mesh mattress
ArmourUniform precast units, linkedGraded quarried stoneStone in wire-mesh boxes or mattresses
FlexibilityFollows settlement; units linkedVery flexible; stones rearrange and can self-healFlexible within the mesh
Design basisTested data of the system plus FS method (HEC-23 DG8)Stone weight and thickness relations (IS 14262 cl. 3)Crate density and thickness relations (IS 14262 cl. 3.6; HEC-23 DG10)
Material supplyCasting yard or factory unitsNeeds suitable quarry within haul distanceStone plus mesh; mesh durability in water
PlacementCrane mats or hand-laid units; good control of thicknessBulk placement; thickness control harder under waterFilled in place or prefabricated
RepairReplace or patch mat sectionsAdd stoneRe-fill or replace baskets
Points to watchSubgrade smoothness, filter, edges, protrusionStone quality and grading, segregationMesh corrosion or abrasion, filling quality

Worked examples

Illustrative numbers for learning, not data from a real project. Every value was recomputed before publication.

Example 1 (exam style, illustrative): scour depth and toe protection length

Problem. An alluvial river has a design discharge Q = 20 000 m³/s and mean bed particle size d = 0.25 mm. HFL − LWL = 5.0 m. Using the Lacey relations in IS 14262 cl. 5.3 and the CWC 2012 apron relations, find the scour depth below HFL, the maximum scour below LWL, the loose-stone apron width, and the length a linked ACBM apron laid at LWL must reach when launched at 2H:1V.

  1. Silt factor f = 1.76√d = 1.76 × √0.25 = 0.88.
  2. Scour depth below HFL D = 0.473(Q/f)^(1/3) = 0.473 × (20 000/0.88)^(1/3) = 0.473 × 28.33 = 13.40 m.
  3. Maximum anticipated scour below HFL = 1.5D = 20.10 m.
  4. Maximum scour below LWL = 20.10 − 5.0 = 15.10 m.
  5. Loose apron width (CWC 2012 4.9.4) = 1.5 × 15.10 = 22.6 m, at thickness 1.5 × pitching thickness.
  6. Launched slope length at 2H:1V = 15.10 × √5 = 33.8 m.
  7. Check of the loose-apron rule: 1.5 × 22.6 = 33.9 ≈ 33.8, so the extra 1.5 × thickness spreads over the longer launched face. A linked mat cannot thicken, so its apron must be detailed to about 33.8 m plus anchorage and overlap.

Answer. D = 13.40 m, Dmax below LWL = 15.10 m, loose apron 22.6 m wide; ACBM apron must reach about 33.8 m down the launched face (plus anchorage)

Example 2 (site style, illustrative): target factor of safety and quantities for an abutment reach

Problem. A bank next to a bridge abutment erodes over a 250 m reach; channel width 150 m. Consequence of failure is medium and a deterministic 2D hydraulic model is used. The slope to be covered rises 7.0 m at 2H:1V; allow 1.0 m into the top trench and a 12.0 m apron mat (from a separate scour check). Using the HEC-23 Figure 8.2 approach (SFB 1.5 for an abutment, XC 1.3, XM 1.1 chosen from its ranges), find the target factor of safety, the protected length and the mat area. Mats are 2.5 m wide.

  1. Target FS = SFB × XC × XM = 1.5 × 1.3 × 1.1 = 2.145, say 2.15.
  2. Longitudinal extent = 250 + 1.0 × 150 (upstream) + 1.5 × 150 (downstream) = 625 m.
  3. Slope length = 7.0 × √5 = 15.65 m.
  4. Mat length per metre run = 15.65 + 1.0 + 12.0 = 28.65 m.
  5. Area = 28.65 × 625 = 17 908 m², about 17 900 m² before overlaps.
  6. Mats per row along the bank = 625 / 2.5 = 250.
  7. The selected system must show, from its own tested data, a computed FS of at least 2.15 at the design velocity.

Answer. Target FS ≈ 2.15; 625 m protected; about 17 900 m² of mat (before overlaps); 250 mats per row

Example 3 (illustrative): filter checks

Problem. (a) Bank sand has D85 = 0.20 mm and 30 % fines. Find the allowable geotextile equivalent opening size (EOS) by IS 14262 Annex A. (b) A granular filter with d50 = 20 mm is proposed under open-cell blocks whose smallest opening is 35 mm. Check it by HEC-23 8.3.5 and give the thickness in the dry and under water.

  1. (a) Fines ≤ 50 %: D85/EOS ≥ 1, so EOS ≤ 0.20 mm; and EOS not smaller than 0.149 mm to limit clogging. Range 0.149–0.20 mm.
  2. (b) d50 must exceed half the smallest opening: 35/2 = 17.5 mm < 20 mm, OK.
  3. Thickness = max(4 × 20 = 80 mm, 150 mm) = 150 mm in the dry.
  4. Under water: 1.5 × 150 = 225 mm.

Answer. EOS 0.149–0.20 mm; granular filter acceptable at 150 mm (dry) or 225 mm (under water)

Practice questions

Tap a question to see the answer.

1What does "articulated" mean in ACBM, and why does it matter?

Each block can rotate relative to its neighbours, so the mat follows settlement and the edge of a scour hole instead of bridging and being undermined.

2How does HEC-23 define failure of an ACB system?

Local loss of intimate contact between the mat and the subgrade, which lets flow get under the blocks.

3A bank rises 5 m at 2H:1V. What slope length does the mat cover?

5 × √5 = 11.18 m (plus top trench and toe).

4Find the HEC-23 style target FS for a channel bank (SFB 1.2), low consequence (XC 1.0) and empirical hydraulics (XM 1.4).

1.2 × 1.0 × 1.4 = 1.68.

5For q = 12 m³/s per m and d = 0.16 mm, find the scour depth below HFL and the maximum anticipated scour (IS 14262 cl. 5.3).

f = 1.76√0.16 = 0.704; D = 1.33(144/0.704)^(1/3) = 7.84 m; maximum = 1.5D = 11.75 m below HFL.

6A channel is 80 m wide. What minimum protected length beyond the attacked reach does HEC-23 suggest upstream plus downstream?

1.0 × 80 + 1.5 × 80 = 200 m in total (80 m upstream, 120 m downstream).

7Maximum scour is 12 m below HFL and HFL − LWL = 4 m. What loose-stone apron width at LWL does the CWC 2012 relation give?

1.5 × (12 − 4) = 12 m.

8Why does HEC-23 leave cable restraint out of the factor of safety?

Any benefit of cables is already in the tested block performance, and cables do not prevent loss of contact with the subgrade; they mainly stop blocks being lost.

9Name two neutral differences between ACBM and riprap.

ACBM uses uniform factory units of controlled weight and is linked; riprap is loose graded stone that can self-heal by rearranging and is easy to repair with local stone. Choice depends on velocity, stone availability, access, cost and maintenance.

Sources

Official and authoritative sources, listed in no order of merit. Our explanations, diagrams and examples are original.

  • Bureau of Indian Standards, IS 14262:1995 Planning and design of revetments – Guidelines: cl. 3.3 bank slope, 3.5 layer thickness, 3.7 filter and Annex A geotextile criteria, 5.1–5.7 toe protection, scour depth and launching apron, 6.1 anchoring. Paraphrased; no text or figures reproduced.
  • Central Water Commission (Flood Management Organisation), Government of India, handbook on flood protection, anti-erosion and river training works (foreword dated June 2012): sec. 4.9.3 sheet piles and launching apron, 4.9.4 size of launching apron, 4.10 anchoring.
  • US Federal Highway Administration, Hydraulic Engineering Circular No. 23 (HEC-23), Bridge Scour and Stream Instability Countermeasures, 3rd ed., Vol. 2, FHWA-NHI-09-112, September 2009, Design Guideline 8 Articulating Concrete Block Systems (8.1–8.4). US Government publication.

Disclaimer. This lesson is for educational purposes only. Examples and numbers marked "illustrative" are not for design or construction. Standards are paraphrased and may be revised; refer to the current official edition from BIS, IRC or the relevant authority. Real work requires a qualified, licensed engineer, site-specific design, method statements and safety assessments. Indiacon does not rank codes, companies or countries and gives no investment advice. Follow the contract specification, the site-specific method statement, statutory safety rules and the instructions of a competent supervisor. Codes and specifications are cited by number and clause only; no text or tables are reproduced. See our corrections policy.

Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.