Beam reinforcement detailing (IS 456:2000 and IS 13920:2016)

Detailing Under review — not yet three-checked Author: Indiacon

Clauses checked on 5 Nov 2026, and re-checked on 10 Nov 2026, against IS 456:2000 (box copy of the BIS text, Table 16) and IS 13920:2016 with Amendment No. 1 (September 2017) and Amendment No. 2 (November 2020). The 30 mm moderate-exposure cover is confirmed in two official texts: IS 456:2000 Table 16 (BIS) and CPWD Specifications 2019 Vol. 1, cl. 5.3.3.5 (checked 13 Nov 2026). Always read the current BIS edition and amendments before design.

Learning objectives
  • Set cover, effective depth and the minimum and maximum tension steel of an ordinary beam by IS 456:2000.
  • Space stirrups for minimum shear steel and the maximum spacing rule, and find a development length.
  • List what changes when the beam is part of an earthquake-resisting frame detailed to IS 13920:2016.

Theory

Cover protects the bars from corrosion and fire. IS 456 cl. 26.4 gives a nominal cover, measured to the outermost steel including stirrups, that rises with the exposure class (Table 16). For moderate exposure the value is 30 mm: IS 456:2000 Table 16 and, independently, CPWD Specifications 2019 Vol. 1, cl. 5.3.3.5 give the same figure (both checked 13 Nov 2026).

Too little tension steel and a beam can crack and fail suddenly; too much and the concrete crushes before the steel yields. IS 456 cl. 26.5.1.1 therefore sets a lower limit on As/(b d) of 0.85/fy and an upper limit on tension steel of 4% of the gross section b D.

When the web of a beam is deeper than 750 mm, wide cracks can open on the side faces between the top and bottom bars. Cl. 26.5.1.3 asks for side-face bars of at least 0.1% of the web area, shared equally by the two faces, at a spacing not more than 300 mm or the web thickness, whichever is smaller.

Every beam gets stirrups, even where the concrete alone could carry the shear (cl. 40.3 and 26.5.1.6). The minimum is set by Asv/(b sv) ≥ 0.4/(0.87 fy), and vertical stirrups may not be spaced more than 0.75 d apart, with an absolute cap of 300 mm (cl. 26.5.1.5).

A bar must be embedded far enough beyond the point where it is needed to transfer its force by bond (cl. 26.2.1). The length is Ld = φ σs/(4 τbd); for deformed bars the plain-bar design bond stress is raised by 60%.

In a frame that resists earthquakes, the beam ends must bend without the concrete core breaking up. IS 13920:2016 adds: at least two 12 mm bars at both top and bottom, a minimum steel ratio of 0.24√fck/fy and a maximum of 2.5% on any face (cl. 6.2), closely spaced hoops over 2d from each column face, and 135° hooks.

Hoop spacing in the 2d end zones (cl. 6.3.5 as amended in 2017) must not exceed the least of d/4, six times the smallest longitudinal bar diameter, and 100 mm; the first hoop sits within 50 mm of the column face. The same close spacing is used for 2d on each side of any other section that may yield in an earthquake (cl. 6.3.5.2). The 2d length is confirmed in a second-publisher commentary: IIT Gandhinagar / IIT Kanpur (NICEE) EQ04, November 2019, which restates cl. 6.3.5 and 6.3.5.2. That document also proposes changing the spacing limits; those proposals have not been adopted, and this page uses the official Amendment No. 1 values.

Hoop hooks are bent through 135° into the core with a straight extension of 8 bar diameters but not less than 75 mm (Amendment No. 1, 2017; the original 2016 text said 6 diameters and 65 mm). A 90° hook can spring open when the cover spalls; a 135° hook stays anchored in the confined core.

Formulas
  • Effective depth: d = D − nominal cover − stirrup φ − main bar φ/2
  • Minimum tension steel (IS 456 cl. 26.5.1.1a): As/(b d) ≥ 0.85/fy
  • Maximum tension steel (cl. 26.5.1.1b): As ≤ 0.04 b D
  • Minimum stirrups (cl. 26.5.1.6): Asv/(b sv) ≥ 0.4/(0.87 fy)
  • Maximum vertical stirrup spacing (cl. 26.5.1.5): sv ≤ 0.75 d and ≤ 300 mm
  • Development length (cl. 26.2.1): Ld = φ σs/(4 τbd), σs = 0.87 fy at the design load
  • IS 13920:2016 end-zone hoop spacing: s ≤ least of d/4, 6 φmin, 100 mm over 2d

Codes and standards

Cited by number and clause only; no clause text, tables or figures are reproduced.

  • IS 456:2000 cl. 26.2.1, 26.2.1.1, 26.4.2 and Table 16, 26.5.1.1 to 26.5.1.6, 40.3 (box copy; later amendments including Amd 6 of 2024 should be checked in the current BIS set)
  • IS 13920:2016 cl. 6.2.1, 6.2.2, 6.3.1, 6.3.5 as amended by Amendment No. 1 (September 2017); terminology and steel clauses as touched by Amendment No. 2 (November 2020)

Worked example

Worked example: 300 × 500 mm beam, M25, Fe500, moderate exposure

Problem. Nominal cover taken from IS 456 Table 16 for moderate exposure (30 mm; IS 456 Table 16 and CPWD Specifications 2019 cl. 5.3.3.5), 8 mm stirrups, 16 mm main bars. Find d, the steel limits, stirrup spacing and Ld.

  1. If the Table 16 moderate-exposure cover of 30 mm is used (IS 456 Table 16; CPWD Specifications 2019 cl. 5.3.3.5), d = 500 − 30 − 8 − 8 = 454 mm. The steps below use this trial d.
  2. Minimum steel: 0.85/500 = 0.17%, so As,min = 0.0017 × 300 × 454 ≈ 232 mm². Three 16 mm bars give 603 mm².
  3. Maximum steel: 0.04 × 300 × 500 = 6000 mm².
  4. Maximum stirrup spacing: 0.75 × 454 = 340.5 mm, so the 300 mm cap governs.
  5. Minimum stirrups, two-legged 8 mm (100.5 mm²): the stirrup fy in this check is taken as not more than 415 N/mm², so Asv/sv ≥ 0.4 × 300/(0.87 × 415) ≈ 0.332 mm²/mm, giving sv ≤ about 303 mm; the 300 mm cap governs.
  6. Ld for a 16 mm bar: τbd = 1.4 × 1.6 = 2.24 N/mm²; Ld = 16 × 435/(4 × 2.24) ≈ 777 mm, about 49 bar diameters.
  7. If the beam is in a ductile frame: end zone = 2d ≈ 908 mm from each column face; hoop spacing ≤ least of 454/4 ≈ 113 mm, 6 × 16 = 96 mm and 100 mm, so 96 mm; hooks 8 × 8 = 64 mm → 75 mm governs.

Step-by-step procedure

  1. Fix the exposure class and nominal cover, then d.
  2. Design flexural steel and check it lies between the minimum and maximum.
  3. Add side-face bars if the web is deeper than 750 mm.
  4. Design stirrups for shear, then apply the minimum and the spacing caps.
  5. Check development length at supports and at bar cut-offs.
  6. If the frame resists earthquakes, apply IS 13920:2016 on top of IS 456.

Site notes

  • Check 135° hooks and hoop spacing near columns before the pour, not after.
  • Cover blocks must suit the nominal cover on the drawing; a 5 mm shortfall over the whole beam is a durability problem.
Common mistakes
  • Measuring cover to the main bar instead of to the stirrup.
  • Using overall depth instead of web depth for the 750 mm side-face trigger.
  • Using the pre-2017 hook extension (6 diameters, 65 mm) or the old 8-diameter hoop spacing rule.
  • Placing laps or construction joints inside the 2d end zones.
Quick check

Quick check for a ductile-frame beam: near each column, hoop spacing is the least of d/4, 6 × smallest bar diameter and 100 mm; hooks are 135° with 8 bar diameters, at least 75 mm.

Summary

  • IS 456: 0.85/fy minimum, 4% bD maximum, stirrups at ≤ 0.75 d and ≤ 300 mm, Ld = φσs/(4τbd).
  • IS 13920:2016 (Amd 1): at least two 12 mm bars top and bottom, hoops at ≤ d/4, 6φ, 100 mm over 2d, 135° hooks with 8φ ≥ 75 mm.

Practice questions

1What is the minimum tension steel ratio for an Fe500 beam by IS 456?

0.85/500 = 0.17% of b d.

2A beam web is 900 mm deep and 300 mm thick. How much side-face steel?

0.1% of 300 × 900 = 270 mm², 135 mm² on each face, spaced at not more than 300 mm.

3Largest vertical stirrup spacing for d = 454 mm?

Least of 0.75 × 454 = 340.5 mm and 300 mm, so 300 mm.

4Ld of a 20 mm Fe500 bar in M25?

20 × 435/(4 × 2.24) ≈ 971 mm.

5Why a 135° hook in seismic hoops?

It stays anchored in the confined core when cover concrete spalls; a 90° hook can open.

Sources

  • Central Public Works Department, CPWD Specifications 2019 Vol. 1, Sub-head 5.0 RCC work, cl. 5.3.3.5 (nominal cover by exposure)
  • Bureau of Indian Standards, IS 456:2000 (Table 16 and cl. 26.4.2 in the box copy) and IS 13920:2016 with Amendment No. 1 (September 2017) and Amendment No. 2 (November 2020)
  • IIT Gandhinagar / IIT Kanpur (NICEE), EQ04: IS 13920:2016 Proposed Modifications and Commentary (November 2019). This records the official Amendment No. 1 hook (8φ ≥ 75 mm) and beam spacing (d/4, 6φ, 100 mm) as the then-current prescription, and restates the 2d close-spacing zone; some of its proposed changes have not been adopted and are not used here.
  • NPTEL course 105105104, Design of Reinforced Concrete Structures, IIT Kharagpur (Modules 3, 4 and 6) — used for the IS 456 steel and stirrup rules, not for the Table 16 30 mm cover.

All detailing pages · Textbook

Suggest a correction

If something on this page is wrong, tell the editor. Your message is sent privately and is not published.