Indiacon Civil

Subjects › Structural Analysis › Advanced and Design

Second-order analysis

Advanced and Design Structural Analysis Reviewed 24 Oct 2026 2 min read

First-order analysis writes equilibrium on the undeformed shape. That is accurate when deflections are small compared with the dimensions, but slender columns and sway frames carrying heavy vertical load behave differently: as the frame sways, the vertical loads act at an offset and create extra moments, which cause more sway. These P-delta effects can raise moments significantly and, in the limit, lead to instability.

Two effects are distinguished. P-big-delta comes from the sway of the whole storey, the vertical load times the storey drift. P-small-delta comes from the curvature of an individual member between its ends. Sway frames are governed mainly by the first; braced members by the second.

Diagram: Indiacon original, not to scale.

A quick estimate uses an amplification factor of one over one minus P over P critical, applied to the first-order sway moments. It shows why a column carrying a fifth of its elastic buckling load already has its moments increased by a quarter. Codes provide such moment magnifiers or require a rigorous second-order analysis when a stability index, comparing the P-delta moment with the first-order storey moment, exceeds a limit.

Software performs second-order analysis by iterating or by using geometric stiffness matrices. Initial imperfections, out-of-plumb columns and member bow, must be included because a perfectly straight model underestimates the effect. Cracking in concrete lowers stiffness and raises second-order moments, so reduced section properties are used.

Tip

Compute P/Pcr for each storey early; if it is below about 0.1 the second-order effect is usually small.

Key formulas
  • Amplification (approximate): M₂ ≈ M₁ / (1 − P / P_cr)
  • Cantilever column: P_cr = π² E I / (2 L)²
  • Storey stability index θ = P Δ / (V h)
Common mistake

Using the member length instead of the effective length when computing Pcr for a cantilever.

Solved example

Problem. A cantilever column 4 m high, EI = 4 × 10⁴ kNm², carries a horizontal load of 20 kN at the top and an axial load of 600 kN. Estimate the second-order base moment.

  1. First-order base moment M₁ = 20 × 4 = 80 kNm.
  2. P_cr = π² × 4 × 10⁴ / (2 × 4)² = 394 784 / 64 = 6 169 kN.
  3. Amplifier = 1 / (1 − 600 / 6 169) = 1 / 0.9027 = 1.108.
  4. M₂ ≈ 1.108 × 80 = 88.6 kNm.

Answer. About 88.6 kNm, roughly 11 percent above the first-order value

Quick quiz

1What is the P-delta effect?

Extra moment from vertical load acting on the deflected shape.

2Why include initial imperfections?

A perfectly straight model underestimates second-order moments.

3Does cracking increase or reduce P-delta effects in concrete?

Increases them, by lowering stiffness.

Code note
  • IS 800 (India): General construction in steel: limit state design of steel members and connections.
  • IS 456 (India): Plain and reinforced concrete: general rules for materials, durability, design and construction.
  • EN 1993 (Eurocode 3) (Europe): Design of steel structures.
  • EN 1992 (Eurocode 2) (Europe): Design of concrete structures.

Cited by number and clause only. We do not reproduce clause text, tables or figures (BIS Act 2016, s.10(5) and s.11). Check the current edition and amendments before use.

References and further reading

Standard texts, listed in no order of merit. We do not copy text, figures, tables or solved problems from any book; our explanations and examples are original.

  • R. C. Hibbeler, Structural Analysis, Pearson, latest edition.
  • C. S. Reddy, Basic Structural Analysis, McGraw Hill Education (India), latest edition.
  • Devdas Menon, Structural Analysis, Narosa, latest edition.
  • A. K. Chopra, Dynamics of Structures, Pearson, latest edition.

Free and official sources

All references for this subject →

Found an error? Write to indiacongroupofengineers [at] gmail [dot] com. For corrections and feedback. We never ask for payment or personal details.